WCS-10 User manual
17
Copyright © TK Engineering Oy 2009 - 2017
4 Device Configuration
While the WCS-10 is CAN networking device, configuration is object-dictionary oriented to enable
use of standard CANopen configuration tools, EDS- and DCF-files.
4.1 Object dictionary overview
Table 6: Communication profile area
Index
Sub-idx
Type
Description
0x1000
0x00
U32
Device type (0x0000 012D)
0x100B 0x00
U8
Node ID
0x1010
Record
Store parameters
0x00
U8
Largest sub-index supported
0x01
U32
Store all parameters (“EVAS” = 0x65 76 61 73)
0x02
U32
Store communication parameters (0x1000..0x1FFF)
0x03
U32
Store application parameters (0x2000..0x9FFF)
0x1015
0x00
U16
Inhibit time EMCY (multiple of 100
s)
0x1017
0x00
U16
Producer heartbeat time (multiple of 1ms)
0x1018
Identity
Identity object
0x00
U8
Largest sub-index supported
0x01
U32
Vendor-ID
0x02
U32
Product code
0x03
U32
Revision number
0x04
U32
Serial number
Table 7: Manufacturer-specific area
Index
Sub-idx
Type
Description
0x2000
0x00
U8
Heartbeat Enable/Disable
0x5010
CAN1 bit rate
0x00
U8
Largest sub-index supported
0x01
U8
CAN1 register BTR0
0x02
U8
CAN1 register BTR1
0x5011
0x00
U32
CAN1 acceptance filter, bank 0
0x5012
0x00
U32
CAN1 acceptance filter, bank 1
0x5015
0x00
U32
CAN1 acceptance mask, bank 0
0x5016
0x00
U32
CAN1 acceptance mask, bank 1
0x5019
0x00
U8
CAN1 filter configuration
0x5020
CAN2 bit rate
0x00
U8
Largest sub-index supported
0x01
U8
CAN2 register BTR0
0x02
U8
CAN2 register BTR1
0x5021
0x00
U32
CAN2 acceptance filter, bank 0
0x5022 0x00
U32
CAN2 acceptance filter, bank 1
0x5025
0x00
U32
CAN2 acceptance mask, bank 0
0x5026
0x00
U32
CAN2 acceptance mask, bank 1
0x5029
0x00
U8
CAN2 filter configuration