background image

 15

Tivok Energy T-HP20AB Heat Pump Installation Manual

3RD 

TIMER SETUP

Flashing

Flashing

Flashing

Flashing

Flashing

Flashing

Flashing

Flashing

Step 4

Step 5

Step 3

Step 7

Step 8

Step 6

Step 10

Step 9

Press          or          to adjust 
the minute value

Press          or          to adjust 
the hour value

Press          or          to adjust 
the minute value

Represents three timers have
been set up

Summary of Contents for T-HP20AB

Page 1: ...Installation and Operation Manual Tivok Energy Heat Pump T HP20AB...

Page 2: ...ing Mode 4 Components 5 Installation 6 Heat Pump Installation 6 Positioning Requirements 6 Water System Installation 7 Water Tank Installation 7 Water Piping Installation 7 Wired Controller Installati...

Page 3: ...n the following subjects System design Wiring and piping materials Connectors Before installing a heat pump you should familiarise yourself with the mechanical and electrical requirements PROPER USE H...

Page 4: ...trophoresis treated in advance and powder painted for maximum corrosion protection to ensure resilience for long term vitality NOISE CONTROL Compressor rubber feet are specially selected for reducing...

Page 5: ...temperature 60 C Defined output quantity 163 litres hour PRODUCT SPECIFICATIONS Dimensions 1002mm 350mm 620mm Packing dimensions 1075mm 380mm 650mm Weight net gross 65kg 79kg Outlet fittings DN20 HEA...

Page 6: ...Tivok Energy T HP20AB Heat Pump Installation Manual 4 SYSTEM DIAGRAM HEATING MODE DEFROSTING MODE...

Page 7: ...ensure stable defrosting Condenser The condenser is a tube in shell exchanger with a big heat exchanging area and high efficiency for hot water solutions Circulation Pump A Grundfos brand circulation...

Page 8: ...uildings and the exhaust air cannot flow back Moreover adequate service clearance should be kept around the unit 6 The unit should not be installed at places near oil flammable gas or corrosive compon...

Page 9: ...on the drainpipe 2 A service valve needs to be installed before the magnet valves on the system pipeline for further inspection 3 The pressure of the water outlet should be between 0 3MPa and 0 6MPa 4...

Page 10: ...ey match 2 Use a screwdriver to open the clip as picture 1 separate the controller into 2 parts as picture 2 3 On the wall that you are going to install the controller drill 2 holes at a level paralle...

Page 11: ...correctly Please open all the valves which should be opened and close all that should be closed before the commissioning Make sure the heat preservation of the water system is in a good condition COMM...

Page 12: ...oose the hour value or minute value Up and Down Press them to adjust the value of water temperature clock timer and parameters During failure checking and parameter checking press any of them to exit...

Page 13: ...th is the temperature value Water tank temperature symbol the figure underneath is the temperature value Parameter number symbol the figure underneath is the parameter number Outlet water tempeature s...

Page 14: ...use either everyday or for only one day In the timer setting status based on the figure shown below it represents NO time sequence has been set However if it shows on the bottom the timer is invalid T...

Page 15: ...he hour value Flashing Step 8 Step 9 Flashing Press or to adjust the minute value Step 10 Flashing Step 11 Flashing Press to return to normal display Flash Normal Display Represents one time has been...

Page 16: ...hing Step 5 Flashing Step 6 Flashing Press or to adjust the hour value Flashing Step 8 Step 9 Flashing Press or to adjust the minute value Step 10 Flashing Flashing Step 11 Press to return to normal d...

Page 17: ...ashing Flashing Flashing Flashing Flashing Flashing Flashing Flashing Step 4 Step 5 Step 3 Step 7 Step 8 Step 6 Step 10 Step 9 Press or to adjust the minute value Press or to adjust the hour value Pre...

Page 18: ...owing steps to set the timer for just one day Running Long press more than 6 seconds Step 1 Standby Step 2 Step 3 Value Press to select the value Adjust the value No 1 represents the incoming electric...

Page 19: ...l the timer It demonstrates how to cancel the first timer and can also be repeated for cancelling the 2nd and 3rd timers Step 1 Step 2 Step 3 Step 4 Step 5 Step 7 Step 8 Step 9 Step 10 Step 6 Press M...

Page 20: ...Manual 18 WATER TEMPERATURE SETTING When heat pump is on simply press or to adjust water temperature When the outlet water temperature is reset the display will automatically return to the normal disp...

Page 21: ...19 Tivok Energy T HP20AB Heat Pump Installation Manual CIRCUIT DRAWING MODEL T HP0AB...

Page 22: ...ure enough capacity and reliability of the heat pump Check the water pump and the valves on the pipes if they work well and make sure there is no leakage from connector Keep the surrounding of the hea...

Page 23: ...system 2 EA Refrigerant leak system 1 PF Refrigerant leak system 2 EF High pressure protection Pressure valve break down system 1 E4 High pressure protection Pressure valve break down system 2 E8 Wat...

Page 24: ...Manual 22 WATER TEMPERATURE SETTING When heat pump is on simply press or to adjust water temperature When the outlet water temperature is reset the display will automatically return to the normal disp...

Page 25: ...23 Tivok Energy T HP20AB Heat Pump Installation Manual CIRCUIT DRAWING MODEL T HP20AB...

Page 26: ...ure enough capacity and reliability of the heat pump Check the water pump and the valves on the pipes if they work well and make sure there is no leakage from connector Keep the surrounding of the hea...

Page 27: ...system 2 EA Refrigerant leak system 1 PF Refrigerant leak system 2 EF High pressure protection Pressure valve break down system 1 E4 High pressure protection Pressure valve break down system 2 E8 Wat...

Page 28: ...rgy T HP20AB Heat Pump Installation Manual 26 PARAMETER CHECKING AND RESETTING The system parameters can be checked and adjusted via the controller however they should only be changed be an approved t...

Page 29: ...temperature auxiliary heat source 2 C 15 C 7 C 48 Numbers over 99 are represented by A for 100 and b for 110 i e A8 is 108 and b8 is 118 For Parameters 13 and 32 the machine off codes are 2 Water tan...

Page 30: ...enoid if it is energised Change the temperature for entering defrosting mode and duration Loud noise coming from compressor Liquid refrigerant entered into the compressor The interior component of the...

Page 31: ...Shortage of oil in the compressor Shortage of lubricant oil Find out the suitable kind of oil for the compressor and inject a small amount Thermostatic throttle valve can t start The switch for it is...

Page 32: ...Tivok Energy T HP20AB Heat Pump Installation Manual 30 NOTES...

Page 33: ...31 Tivok Energy T HP20AB Heat Pump Installation Manual NOTES...

Page 34: ...Tivok Energy T HP20AB Heat Pump Installation Manual 32 Tivok Energy Pty Ltd 4 51 53 Bourke Rd Alexandria NSW 2015 Australia www tivok com au T 6 12 8084 7905 F 6 12 8076 3162 E info tivok com au...