Health Surveillance.

All employees should be part of an employer’s health surveillance scheme to help identity 
any vibration related diseases at an early stage, prevent disease progression and help 
employees stay in work.

Double insulation:

The tool is double insulated. This means that all the external metal parts are electrically 
insulated from the mains power supply. This is done by placing insulation barriers between 
the electrical and mechanical components making it unnecessary for the tool to be earthed.

Important note: 

Be sure the supply is the same as the voltage given on the rating plate. The tool is fitted 
with a two-core cable and plug. Remove the mains plug from socket before carrying out any 
adjustment or servicing.

  

400w 高枝.indd   10

12-3-2   上午11:36

Summary of Contents for TTB427GTM

Page 1: ...SAFETY AND OPERATING MANUAL Original Instructions v 24month Manufacturer s Warranty POLE HEDGE TRIMMER 400W TTB427GTM 400w indd 1 12 3 2 11 36...

Page 2: ...GUARANTEE This TITAN product carries a guarantee of 24 months If your product develops a fault within this period you should in the first instance contact the retailer where the item was purchased Thi...

Page 3: ...rden power tool must be kept out of reach of children 4 Store the instruction manual in a location accessible to all users of the garden power tool and always include the instruction manual when passi...

Page 4: ...g to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents 4 Remove a...

Page 5: ...n a hazardous situation Service Have your garden power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the garden power tool is ma...

Page 6: ...chanism strikes any foreign object or the product starts making any unusual noise or vibration switch the product off allow the product to stop disconnect it from the power supply and let it cool down...

Page 7: ...e of operation use low vibration and low noise operating modes as well as wear personal protective equipment Take the following points into account to minimise the vibration and noise exposure risks 1...

Page 8: ...to prevent risks and hazards 1 Always be alert when using this product so that you can recognise and handle risks early Fast intervention can prevent serious injury and damage to property 2 Switch off...

Page 9: ...re WARNING The vibration emission value during actual use of the power tool can differ from the declared value depending on the ways in which the tool is used dependant on the following examples and o...

Page 10: ...ulated This means that all the external metal parts are electrically insulated from the mains power supply This is done by placing insulation barriers between the electrical and mechanical components...

Page 11: ...tion Wear safety helmet Wear face protection Gloves with saw protection Boots with saw protection steel toecap and non slip sole Wear protective clothing To avoid potential electric shock do not use t...

Page 12: ...children must not come near the area where the product is Minimum distance 15 m Always beware of the danger from overhead electric power line keep a safe distance at least 10M from the power line Wast...

Page 13: ...le adjustment 3 Upper shaft 4 Middle shaft 5 Fixation knob 6 Securing clip upper lower 7 Harness 8 Lock off button 9 Switch trigger 10 Main handle 11 Power cord with plug 12 Cord strain relief 13 Rear...

Page 14: ...used for comparing one tool with another The declared vibration value may also be used in a preliminary assessment of exposure WARNING The vibration emission value during actual use of the tool can d...

Page 15: ...ONS 1 UNPACK a Unpack all parts and lay them on a flat stable surface b Remove all packing materials and shipping devices if applicable c Make sure the delivery contents are complete and free of any d...

Page 16: ...wer adjustable section is NOT to increase the cutting length but to alter the harness positions 3 CABLE ROUTING 1 Always route the electric main cable away from the work area to prevent it from coming...

Page 17: ...leads should not be used under any circumstances as they may cause fatal injuries due to their damaged insulation sheath 4 Always check the plug and cable and make sure they are in good condition befo...

Page 18: ...a 2 Adjust the head until it snaps securely into place at one of the four positions indicated by the notches See Fig 4b 7 STARTING AND STOPPING 1 STARTING The pole hedge trimmer is fitted with a lock...

Page 19: ...upport 4 Ensure that the air vents are always unobstructed and clean Clean them if necessary with a soft brush Blocked air vents may lead to overheating and damage the product 5 Switch the product off...

Page 20: ...tting area out of sight See Fig 6c 8 Do not to rush and do not attempt to cut too much with one stroke of the cutting blade NOTE Try to keep the cutting blade angled at approximately 15 to the cutting...

Page 21: ...particular clean the air vents after every use with a cloth and brush 5 Clean the pole hedge trimmer with a brush or cloth Do not use any solvents or water to remove dirt Remove stubborn dirt with hig...

Page 22: ...aft 3 Repeat in the same way for middle shaft 4 and lower shaft 19 See Fig 8 Now you can replace any worn inner cable 4 STORAGE 1 Clean the product as described above 2 Store the product and its acces...

Page 23: ...ist electrician Other electrical defect to the product Check by a specialist electrician Product does not reach full power Extension cord not suitable for operation with this product Use a suitable ex...

Page 24: ...entifying the terminals in your plug proceed as follows The wire which is coloured blue must be connected to the terminal which is marked with N The wire which is coloured brown must be connected to t...

Page 25: ...02 96 EC and 2003 108 EC Waste Electrical and Electronic Equipment WEEE The conformity assessment followed was according to Annex III of the directive for equipment listed in schedule 1 article 13 the...

Page 26: ...400w indd 26 12 3 2 11 36...