21
DURING THIS PROCESS CAUSING EXCESSIVE NOISE, USE ADDITIONAL FASTENERS TO
BETTER SECURE THE DRAIN LINE.
Touch the REGENERATION ICON. You will be given a choice to regenerate “now” or “at
regen time” - select “now” to engage a full backwash and rinse cycle. Allow the backwash
and rinse to run their full cycles.
When the system returns to service mode, slowly open a nearby cold water tap (after the
TITAN-Ox™ system) and let the water run for 5 to 10 minutes until the system is purged of all
air that may have resulted from the installation, and the water is running clear. Repeat for
other faucets in the building starting at the highest elevation and working down to the lowest
point until all air is purged. The initial flow of water may be slightly discolored. This is normal
and will go away quickly.
It is now safe to turn the electricity back on to your water heater.
Congratulations!
Your system is now ready to provide treated water to your home!
PERFORMANCE MONITORING
The contaminants removed by this treatment system, including arsenic, uranium, lead and
other heavy metals are harmful and can cause serious negative health effects. We strongly
recommend a stringent ongoing water testing program to monitor the performance of your
TITAN-Ox™ system. In the event that contaminant levels exceed U.S. EPA or Health Canada
guidelines, your media may need to be replaced or backwash settings may need to be
altered to improve contaminant reduction (to reduce channeling). Contact your dealer for
advice and assistance.
We have included a basic arsenic monitoring testing kit (5 tests) with your system. This kit is
ONLY for arsenic testing. If you are monitoring other contaminants, you will need an
alternate test kit or to use a certified water testing laboratory. Follow the test kit
manufacturer’s instructions very carefully to ensure accurate results. We recommend the
following testing schedule following installation:
Test 1: within 24 hours of installation