27
Totalizer:
This is the total volume of water in gallons (U.S.) that have been treated by the
system since the totalizer meter was last reset. To reset the totalizer meter, touch “totalizer”
and then select the icon in the bottom right corner of the next screen. The totalizer meter will
be reset to zero. The totalizer can be useful in monitoring water consumption to estimate the
remaining life of your media.
The second screen displays when the last regeneration (flush cycle) occurred as well as the
software version that is used by your control valve.
The third screen indicates the number of flush cycles that the valve has done as well as the
average interval between regenerations (flushes) based on the last 4 cycles.
Daily Usage:
In this area, you can access daily water usage information for the past month.
The first screen allows you to see the average water usage by day of the week (use the >
and < icons to view other days of the week). Select a day of the week to see detailed water
consumption data on this day of the week for the last month.
The final Diagnostic Mode screen provides details as to how much water has been
processed since the last flush cycle and when the programming settings were last changed.
To exit the Diagnostics Mode, press the home icon in the bottom right corner of the screen.
MASTER SETTINGS MODE
THE MASTER PROGRAMMING MODE IS DESIGNED FOR PROFESSIONAL USE ONLY.
UNLESS DIRECTED BY A WATER TREATMENT PROFESSIONAL FAMILIAR WITH THE
SYSTEM, IT IS STRONGLY RECOMMENDED THAT YOU DO NOT MODIFY ANY OF THE
MASTER PROGRAMMING MODE SETTINGS
To enter the Master Settings Mode, select the SETTINGS ICON from the home screen, then
select the SETTINGS ICON again. The password is: 1201
The following settings are the factory default settings: