4.1.3- WAN >> Basic Settings >> Utils 

 

The utilities that you can find at the bottom of the “WAN > Basic Settings” screen allow you to select 
the main and secondary GSM operators when using a Global SIM card. (A Global SIM card allows you 
to connect to several network operators that are available. For example, in Spain, you would be able 
to connect to Movistar, Vodafone or Orange).  

 

 

Strong Scanning

:   This scans the GSM stations for all available network operators.  This 

action uses a significant amount of processing power and therefore can take up to 4 
minutes. On occasion, it may be necessary to try the process again. If successful, a list of 
the detected BTS will be shown, indicating the operator’s name, its code, its availability and 
the type of network (2G/3G). This could be very useful in helping you decide the best 
operator to use in a particular place.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MTX-Router-Titan

Page 1: ...t to changes without prior notice User manual Models MTX Router Titan 3G mini MTX Router Titan 3G mini GPS MTX Router Titan 4G mini GPS MTX Router Titan mini only Eth Wifi MTX Router Titan 3G MTX Router Titan 3G GPS MTX Router Titan 3G WC25 MTX Router Titan 4G GPS MTX Router Titan only Eth Wifi ...

Page 2: ...Router Titan 3G mini IP Camera 3G ETHERNET ADSL Relay control via SMS and status changes IP and SMS alarms MTX Temp RS232 temperature sensor RS232 WWW Server Database Temperature Data JSON RS485 RS485 RS485 Modbus Meter Modbus Meter Modbus Meter Modbus Meter RS485 Internal Relay DynDNS Weather station with USB port Digital Input Open door alarm Internet Access for Wi Fi enabled devices ...

Page 3: ...tal direct indirect punitive or other damages whatsoever including without limitation damages for loss of business profits business interruption loss of business information or data or other pecuniary loss arising out the use of or inability to use the documentation and or product even if Matrix Electronica has been advised of the possibility of such damages The foregoing limitations of liability ...

Page 4: ... 4 WAN Keep Online 21 4 2 LAN 22 4 2 1 LAN Basic Settings 22 4 2 2 LAN DHCP Server 23 4 3 Wi Fi 24 4 3 1 Wifi Basic Settings 24 4 3 2 Wi Fi DHCP Server 26 4 4 Firewall 27 4 4 1 Firewall NAT 27 4 4 2 Firewall Authorized IPs 29 4 5 Serial Settings Serial portX 31 4 6 External Devices 35 4 6 1 External Devices Logger configuration 35 4 6 2 External Devices Temperature Sensor 38 4 6 3 External Devices...

Page 5: ...ric Serial Device 53 4 7 1 Other DynDns 55 4 7 2 Other Private DynDns 56 4 7 3 Other RelayX 58 4 7 4 Other AT Command 62 4 7 5 Other SMS Control 63 4 7 6 Other Periodic autoreset 65 4 7 7 Other Custom Skin 67 4 7 8 Other Custom LED 68 4 7 9 Other Time Server NTP 69 4 7 10 Other Remote console 70 4 7 11 Other Passwords 71 4 7 12 Other User Permissions 72 4 7 13 Other Backup Examples 73 5 7 14 Other...

Page 6: ... a serial device with a 3G RS232 gateway whilst Internet access is given to a device with an Ethernet port 140 Example Scenario 2 3 Configuration to provide Internet access to a device with an Ethernet port Another serial device will be connected to the router via an RS232 port in order to send SMS messages via AT commands 143 Example Scenario 2 4 Configuration to remotely access a USB device via ...

Page 7: ...after detecting Jamming GSM inhibitor Remote control of an IP camera via GPRS Changing a relay and making a warning call when possible Jamming is detected Sending SMS alerts when an open gate is detected 170 Example Scenario 2 13 Autonomous reading of Modbus registers and automatic sending to two web platforms HTTP GET will be used to send the registers to one platform and to the other we will sen...

Page 8: ...standing of the possibilities of these routers we strongly recommend that you read Chapter 2 of this manual the FAQs After reading this you will have a greater vision of what it can do Once you have read the FAQs take a look at the examples in the Annex These examples will provide you with a clearer understanding of the routers possibilities All users of our MTX modems and routers are provided wit...

Page 9: ...of the MTX Router Titan 3G and MTX Router Titan 3G mini devices like Below you have an image of the MTX Router Titan 3G And an image of the MTX Router Titan 3G mini What can I do with the MTX Router Titan 3G and MTX Router Titan 3G mini devices Basically everything that can be done with a standard 3G router is possible with this device with the addition of several advanced gateway benefits For exa...

Page 10: ...so capable of picking up and managing a GSM data CSD call for Metering applications Is it possible Yes but with restrictions The MTX Router Titan must force itself to work in 2G mode In this way it can carry out the normal functions of the router at the same time that it manages a CSD calls that is received without problem I want a 3G router but I need to be able to send AT commands directly to it...

Page 11: ...arm or IP message when the temperature is above or below a pre determined level etc The Maxbotix RS232 distance sensor works exactly the same The MTX device can periodically send the measurements or send SMS alarms or IP messages whenever the distance measured is greater than or less than a particular value Typical applications include grain silos Does it work the same for waveflows It works in a ...

Page 12: ...er Titan 3G and MTX Router Titan 3G mini have a real time clock Yes they do It is synchronized using NTP via Internet In the current version 1 01 UTC time is used Is there a digital entry to send alarms in case of changes Yes but only with the MTX Router Titan 3G mini device Can the MTX devices be configured by SMS Yes they can You can send AT commands via SMS in order to restart the device change...

Page 13: ...es carry out all the previous simultaneously Yes they can For example 3G RS232 gateways can run alongside a 3G USB gateway whilst allowing a device to connect to the Internet using its Ethernet connection or giving Wi Fi connectivity to PDAs whilst using DynDNS timed relays or sending to the Cloud readings from water meters obtained by RF868MHz etc All this can work simultaneous and in harmony ...

Page 14: ...wser Chrome IExplorer Firefox and Ethernet port An Ethernet cable to connect the PC with the MTX device Steps to access the configuration environment 1 Connect the Ethernet cable to the PC and MTX device 2 The PC must have a fixed IP address and of the form 192 168 1 X given the default IP address of the MTX Router Titan 3G and MTX Router Titan 3G mini devices is 192 168 1 2 3 Open a browser with ...

Page 15: ...N Status This screen shows the general status of the router Public IP WAN IP address address of the GPRS 3G connection if available GSM Module indicates the manufacturer and the router s internal GSM module model Network 2G 3G indicates if the current WAN connection is using 2G GPRS or 3G RSSI indicates the signal strength 0 none 31 maximum Internal Temperature shows the internal processor s tempe...

Page 16: ... this Username Operator Username Consult your GSM provider for this Password Operator Password Consult your GSM provider for this Call center Call Centre Number Usually 99 1 Sim Pin If your SIM card has a PIN number it should be specified here Authentication The method of authentication Usually PAP Network selection auto the router will use 3G when 3G coverage is available and 2G in the event that...

Page 17: ...l Rel3 00 3 09 Page 17 http www mtxm2m com Subject to changes without prior notice Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect ...

Page 18: ...rk operators that are available For example in Spain you would be able to connect to Movistar Vodafone or Orange Strong Scanning This scans the GSM stations for all available network operators This action uses a significant amount of processing power and therefore can take up to 4 minutes On occasion it may be necessary to try the process again If successful a list of the detected BTS will be show...

Page 19: ...st results button in order to see the results Light Scanning This carries out a similar process but only those operators that are available for your SIM card are identified 3G connectivity is not lost during the process which could last up to 2 minutes meaning that it is ideal when carried out remotely via 3G Choose operators This allows you to choose the GSM operator and the secondary operators I...

Page 20: ...try to connect to a GSM network automatically If we select the Automatic option instead of Main and Backups the router will try to select the operator in the order that is stablished in the SIM card s internal tables Except for in locations prone to connectivity problems we recommend you use the Automatic option The section Wan Basic Settings Utils is not available for 4G models ...

Page 21: ...onnection will be reset We recommend the use of this characteristic Enabled activate this option to allow the MTX Router Titan to periodically send a PING to check the connectivity Ping Server indicates the server s IP address where the PING should be sent Period indicates how frequently a PING should be sent Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes...

Page 22: ... a local IP address of the Ethernet interface by default 192 168 1 2 IP Subnet Mask Subnet mask DNS1 main DNS server DNS2 secondary DNS server IP Gateway gateway IP address Leave this in blank if you are going to use 2G 3G networks For example if would be useful if you wanted to provide Internet connectivity to Wi Fi devices but redirecting the output towards the IP address of an ADSL router inste...

Page 23: ...tarting IP Address indicates the first IP address that the DHCP server will assign Ending IP Address indicates the last IP address that the DHCP server will assign MAC Address IP Address these two parameters allows the DHCP server to assign the same IP address to a specific MAC address Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Click SAVE RULE for eac...

Page 24: ... mode this indicates the SSID created by the Titan router in Wifi Client mode this indicates the SSID that the Titan router will connect to Security This parameter allows you to specify the Wi Fi security mode WPA2 is recommended KEY This parameter specifies the Wi Fi password that is necessary for WPA2 mode IP Mode In Wifi Client mode this specifies if a local static IP address is to be used or w...

Page 25: ...l Rel3 00 3 09 Page 25 http www mtxm2m com Subject to changes without prior notice Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect ...

Page 26: ...d Starting IP Address indicates the first IP address that the DHCP server will assign Ending IP Address indicates the last IP address that the DHCP server will assign MAC Address IP Address these two parameters allow the DHCP server to always assign the same IP address to a particular MAC address Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Click SAVE R...

Page 27: ...you wish to have access from an outside computer you should configure this section appropriately You can create up to 10 rules Service name name to describe the mapping rule Protocol indicates the protocol for port mapping TCP UDP or both Input port indicates the listening port for the MTX Router Titan 3G device Output port indicates the listening port of the device that is connected to the MTX Ro...

Page 28: ... changes to take effect Also remember that to create a NAT correctly 1 The LAN IP address of the device to be controlled should be within the network range of the LAN IP address of the MTX Router Titan 3G device or the MTX Router Titan 3G mini device 2 The Gateway IP address of the device to be controlled should be the LAN IP address of the MTX Router Titan 3G device or the MTX Router Titan 3G min...

Page 29: ...have been authorized Remote console Specifies if remote connections to remote control services will be accepted from any IP address or only from those that have been authorized NAT Specifies if remote connections to the router s mapped ports will be accepted from any IP address or only from those that have been authorized ModBus TCP Slave Specifies whether remote connections to the Titan router s ...

Page 30: ...ctions are only for 3G connections Wi Fi access remains protected by the WPA2 password Therefore if you have Wi Fi and require security activate WPA2 in the section Wifi Basic Settings If the Outgoing connections restriction is used remember that the DNS server s IP address must be specified if domain names are used instead of IP addresses If you need to authorize more than three IP addresses you ...

Page 31: ...ands must be sent between the tags MTXTUNNELR and MTXTUNNELR For example if we want to obtain the network coverage the following command can be sent MTXTUNNELR AT CSQ MTXTUNNELR or if we wish to remotely reset a device we can send the following command MTXTUNNELR AT MTXTUNNEL REBOOT MTXTUNNELR Allow incoming GSM calls CSD Data Call by selecting this option we accept CSD calls via serial ports This...

Page 32: ...ed 30 seconds before activing a temporary client This option therefore offers greater security to your 3G RS232 gateways Once the temporary socket closes the OpenVPN connection is also closed freeing up the server SSH Enabled By activing this option you will be able to configure an IP Serial Gateway with SSH security encrypting communications For such gateways the port to be uses is 20022 SSH Pass...

Page 33: ...ernal Modem select this option if you wish to directly communicate with the internal modem of the MTX Router Titan 3G or MTX Router Titan 3G mini device For example if you wish to make a GSM call if you want to send an SMS or if you want to send any AT command Using this option could on occasion affect the rest of the router s benefits for example if you send a special AT command to activate the P...

Page 34: ...tan 3G device for special communication cards RF868MHz GPS etc i e it is not an external serial port of the MTX Router Titan 3G or MTX Router Titan 3G mini device The serial ports of the type USB refer to a virtual serial port that is created inside the MTX Router Titan 3G or MTX Router Titan 3G mini device when a connection to a USB device is made Do not use this COM if a USB device is not connec...

Page 35: ...to set up the mode to send data to a platform via HTTP GET in JSON format Mode data sending mode The options available HTTP GET JSON HTTPS GET JSON HTTP GET PARAMETERS HTTPS GET PARAMETERS HTTP PUT PARAMETERS HTTPS PUT PARAMETERS or directly with the GroveStreams platform Custom parameters This option allows you to add optional parameters for HTTP GET and HTTP PUT methods Custom header1 and Custom...

Page 36: ...e format is JSON FTP Server FTP server used to send data FTP Path Path inside the server where to send the data FTP Username The username of the FTP server account that allows you to write FTP Password The password of the FTP server account that allows you to write FTP File Period The frequency with which you want the Titan to send the data files to the server every day every hour every minute etc...

Page 37: ...the data in its internal memory and send it when communications are restored When FTP mode is used to send the data the data is stored in a JSON register file and it is sent according to the frequency specified every minute hour day etc If there is no GSM coverage or problems occur with the sending of data for example the remote server fails the Titan device will store the data in its internal mem...

Page 38: ...end this to a web platform you need to select this option This option should not be selected if you only want to send an SMS alert when the temperature is outside preset margins Alarms enabled Select this option if you want to activate the alarms when the temperature is outside margins Max Temperature The maximum temperature before which an alarm is sent due to high temperature Text alarm on max T...

Page 39: ...ple if you configure 50ºC to be a high temperature the alarm will be activated when the temperature reaches 50ºC However it will not be considered deactivated until it falls below 49ºC so as to avoid the constant sending of SMS messages when the temperature is just inside the selected range Sample format of the JSON string sent IMEI 358884050088207 TS 25 12 2014 17 40 09 TYPE TEMP P 1234 TEMP 25 5...

Page 40: ...Rel3 00 3 09 Page 40 http www mtxm2m com Subject to changes without prior notice P the logger s ID field External Devices Logger configuration TEMP temperature ALTH alarm due to high temperature 0 no 1 yes ALTL alarm due to low temperature 0 no 1 yes ...

Page 41: ...e readings periodically to your webserver you can specify here the period in minutes Logger If you wish to use the internal logger to store distance data to later send this to a web platform you need to select this option This option should not be selected if you only want to send an SMS alert when the distance is outside preset margins Alarms enabled Select this option if you want to activate the...

Page 42: ...es Remember that the router should be restarted for the changes to take effect Sample format of the JSON string sent IMEI 358884050088207 TS 25 12 2014 17 40 09 TYPE DIST P 1234 DIS 500 ALDH 0 ALDL 0 Where IMEI the router s ID number Unique for each device TS time stamp DD MM YYYY HH MM SS TYPE type of string In this case it is distance P the logger s ID field External Devices Logger configuration...

Page 43: ...Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 43 http www mtxm2m com Subject to changes without prior notice ALDH alarm due to long distance 0 no 1 yes ALDL alarm due to short distance 0 no 1 yes ...

Page 44: ...tore the read Modbus registers to later send this to a web platform you need to select this option Device name identifying name of the Modbus RTU device Address Modbus RTU address of the device to be read Command Modbus read command Start Register where reading shall start Num Words Number of registers to be read Reg type Type of registers to be read Period Period of readings i e how often in minu...

Page 45: ...ion is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect If you wish to create a new Modbus RTU device you must complete the form data and click SAVE DEVICE Sample format of the JSON string sent IMEI 354740050367237 TS 17 02 2014 19 02 46 TYPE MODB P 1234 ST 1 A 1 V 1 2 3 4 5 6 7 8 9 10 Where ...

Page 46: ... Modbus to SNMP gateway This section describes the process to implement a Modbus SNMP gateway allowing almost any Modbus RTU or Modbus TCP device to be intregated into an SNMP network An additional Application Note is available AN8 Router Titan Modbus to SNMP Gateway pdf in which detailed information including examples regarding this option can be found Enabled Activate this option to enable the M...

Page 47: ...ces can be programmed sending at a later time the readings to a webserver via a JSON object or via the logger using FTP Enabled Activate this option to enable Waveflow communications Serial Port Select the serial port Serial Port 4 TTL for the Titan router and Serial Port 5 USB when using the Titan mini model Period In this field indicate how frequently in minutes you wish the data sensors to be r...

Page 48: ...nputting the MAC address of the device to be used with boosters in the MAC address field For example if we wish to use boosters 2 and 5 for the Wavetherm device with MAC address 010203040506 we would insert 010203040506 2 5 remember that semi colons are used for separation 4 6 5 3 External Devices Wavenis Tools In this section you will find tools to remotely access Wavenis devices at any time Simp...

Page 49: ...ca MTX Router Titan User Manual Rel3 00 3 09 Page 49 http www mtxm2m com Subject to changes without prior notice Generic Read Battery Counter This field allows you to obtain an estimation of the remaining battery life ...

Page 50: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 50 http www mtxm2m com Subject to changes without prior notice ...

Page 51: ... fleet management system using GPS Output redirection This option allows NMEA position frames to be redirected through one of the RS232 RS485 serial ports or the USB port of the Titan device In this way GPS can be used by an additional serial port device TCP Port Redirection In the same way NMEA frames can be obtained via an RS232 or RS485 serial port or the USB port it is also possible to obtain ...

Page 52: ...0 3 09 Page 52 http www mtxm2m com Subject to changes without prior notice Additional Notes Once the configuration is complete press the SAVE CONFIG button to save the changes Remember that the router should be reset in order for the changes to take effect ...

Page 53: ...ce with the Titan router acting as a datalogger Serial Port Select Titan router s serial port used for logging Interval Selecting a value of 0 means all serial frames that are received will be collected A value of 1 will collect every other frame that is received A value of 2 will collect one of every three frames received Only Changes Activate this option if you only wish to log frames that are d...

Page 54: ...0 3 09 Page 54 http www mtxm2m com Subject to changes without prior notice Additional Notes Once the configuration is complete press the SAVE CONFIG button to save the changes Remember that the router should be reset in order for the changes to take effect ...

Page 55: ...rvice server members dyndns org or dynupdate no ip com Domain Indicate the DNS that you have created for example midominio dyndns org Login login for your DynDNS or No IP account Password password for your DynDNS or No IP account Period the period in minutes that the current IP address in the DynDNS or No IP servers should be refreshed Additional Notes Once the configuration is finished click SAVE...

Page 56: ... sending of a specific string via socket to a configurable TCP port Enabled Activate this option if you wish to use the Private DNS Mode you can choose between HTTP GET JSON or through a text string via a TCP socket Server the IP or DNS where the IP is to be sent Server Login login for your webserver if http get mode is used Password password for your webserver if http get mode is used TCP Port TC...

Page 57: ...ve the changes Remember that the router should be restarted for the changes to take effect Sample format of the JSON string sent IMEI 358884050088207 TYPE DNS P 1234 IP 200 1 2 3 RSSI 25 Where TYPE type of string In this case DNS IMEI router s ID number Unique for each device P Logger s ID field External Devices Logger configuration IP IP of WAN interface 2G 3G RSSI 0 31 signal strength ...

Page 58: ...deactivate the relay SMS On Off with text SMS text used to activate the relay for 3 seconds Used to carry out resets of external devices with just one SMS External Devices Temperature Sensor Activate this option if you wish to change a relay according to the temperature of a sensor connected to the router s serial port External Devices Temperature Sensor Max Temperature maximum temperature after w...

Page 59: ...s Movement Detection Seconds Time in seconds during which the relay will be active after detecting movement GPS Area Activate this option if you wish to change the relay when the Titan router is located within a GPS area defined in the section External Devices GPS Receiver BTC Experimental Activate this option if you wish to change the relay when a bank transfer is detected in a specified Bitcoin ...

Page 60: ... finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect Sample format of the JSON string sent IMEI 354740050367237 TS 17 02 2014 19 02 46 TYPE RELAY P 1234 ID 1 VAL 0 WHY AT WHYH Where IMEI router s ID number Unique for each device TS time stamp DD MM YYYY HH MM SS TYPE type of string In this case Modbus ...

Page 61: ... because of Schedule 2 TEMP relay changed because of temperature DIST relay changed because of distance AT relay changed because of AT command JAMM relay changed because of suspect jamming ACCEL relay changed because of detected movement GPS relay changed because of the GPS cell ASTRO relay changed because of the astronomic relay BITCOIN relay changed because of a received transfer WHYH if the rel...

Page 62: ...work coverage identify the telephone cells in the area etc It is also possible to configure up to five special AT commands which can be used to configure the router upon startup AT Command AT command for real time execution for example AT CSQ Once SEND AT COMMAND is clicked the command will be executed AT1 AT5 start up AT commands Additional Notes Once the configuration is finished click SAVE CONF...

Page 63: ...command SMS messages For example if you write mtx in this box when an AT command is sent via SMS let s say the ATI command which is used to find out the router s internal module we would need to send an SMS with the text mtx ATI All phones activate this option if you want all telephones to be able to send AT commands to the router Do not activate this option if you only want a specified number of ...

Page 64: ... com Subject to changes without prior notice Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect Consult the Application Note ALIAS SMS for further information and examples ...

Page 65: ...ber of hours if you decide you want the router to reset itself every X hours you need to specify in this box the frequency in hours of the reset For a daily reset input 24 Auturoreset at specific time select this option if you want the router to reset itself a specific time of the day Time for autoreset if you choose the previous option specify here the time of reset Autoreset if router can t obta...

Page 66: ...l Rel3 00 3 09 Page 66 http www mtxm2m com Subject to changes without prior notice Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect ...

Page 67: ...nalized feel to the product Set custom image select an image with 922 x 172 pixels tipo gif for the header Set custom labels input the text that you want to appear in the title and the footer Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that if you configure the router with your own header and customized texts for third party users it is not ne...

Page 68: ...without use Not IP the red LED will light up whenever the router does not have an assigned WAN IP address Not ping the red LED will light up whenever the router does not receive a response to a PING configured in the WAN section the ping that checks connectivity Bad RSSI the red LED will light up when the network coverage is weak providing a sign that it would be better to move the antenna or use ...

Page 69: ...nization with time servers via NTP protocol Enabled activate this option if you wish to use the NTP time servers NTP Server 1 IP address or DNS of time server 1 NTP Server 2 IP address or DNS of time server 2 Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect For firmware versions 2 0...

Page 70: ...ection Look at section 5 of this manual for a list of AT commands available Enabled activate this option if you want to use this special connection TCP Port router s listening TCP port where the connection should be made Login username that will be required after a connection is made Password password that will be required after a connection is made Additional Notes Once the configuration is finis...

Page 71: ...There are two usernames that can be used to access the router s configuration The username admin from which you will have access to the entire configuration and user from which you will have access to only the selected configurations useful for when the router is personalized you re your logos In this section you can change the password for both users ...

Page 72: ...n this section you can configure the permissions for the users that use the user account The configuration options that are not selected will not appear in the left hand menu for the user account Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect ...

Page 73: ... It also allows you to load the user manuals quickly and easily Factory Settings button press this button if you want to restore the router to its factory settings Download settings link press this link to download the router s configuration in a file with the name config mtx Upload button to carry out a restoration according to a saved configuration press this button to load the file after having...

Page 74: ...itch 8 to the OFF position Remember that the default IP address of the router is 192 168 1 2 and the login is admin and the password is admin In Anex A you will find more information about micro switches Procedure for the MTX Router Titan 3G device Open the casing of the device where you will see two chips SW1 and SW2 each with eight micro switches Make sure the router is switched off and place SW...

Page 75: ...input as an alarm SMS select this option if you want to send an SMS alart when a change is detected Call select this option if you want to make a call as an alarm when a change is detected Phone numbers you can enter up to 5 telephone numbers to make calls or send SMS alarms Text SMS Alarm On if you choose to send SMS alarms the text inputted here will be sent when the alarm is activated Text SMS ...

Page 76: ...otice Additional Notes Once the configuration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect Sample format of the JSON string sent when the Logger option is chosen IMEI 354740050367237 TS 17 02 2014 19 02 46 TYPE DINPUT P 1234 VAL 0 ID 1 COUNT 0 ...

Page 77: ...MEI the router s ID number Unique for each device TS time stamp DD MM YYYY HH MM SS TYPE data type In this case digital input P Logger ID field External Devices Logger configuration VAL 1 activated 0 deactivated ID 1 digital input 1 2 digital input 2 COUNT if configured as a pulse counter this value returns the number of pulses counted ...

Page 78: ...tensity is low either because the intruder is getting closer or nearer an SMS can be sent If there is an intense level of jamming the sending of an SMS will be impossible Detection mode Disabled if you do not want to use this option Enabled for GPRS if you want to activate jamming detection for GSM GPRS networks Sensibility select between low medium or high sensitivity Better detection is achieved...

Page 79: ...uration is finished click SAVE CONFIG to save the changes Remember that the router should be restarted for the changes to take effect Sample format of the JSON string sent when the Logger option is chosen IMEI 354740050367237 TS 17 02 2014 19 02 46 TYPE JAMM P 1234 VAL 1 Where IMEI the router s ID number Unique for each device TS time stamp DD MM YYYY HH MM SS ...

Page 80: ...er Titan User Manual Rel3 00 3 09 Page 80 http www mtxm2m com Subject to changes without prior notice TYPE data type In this case digital input P Logger ID field External Devices Logger configuration VAL 1 activated 0 deactivated ...

Page 81: ...ou can create a script so that whenever a Modbus register in device A has a specific value the Titan writes a different value in a Modbus register in device B Or you can send an SMS change a relay etc when a Modbus register in device A has a specific value The Titan Scripts given they are editable by the user allow you to create an infinite number of different applications with little effort Below...

Page 82: ...de this would be If what the first text box says is true Execute the action in the second text box If what the first text box is not true Execute the action in the third text box Even though we still do not know the commands available let s see an example This example will be interpreted as follows If the sum of register 10 of the Modbus device with the address 1 and register 11 of the Modbus devi...

Page 83: ...Description Reads a Modbus RTU device register Can be used on the IF field or the ACTION1 or ACTION2 fields Parameters modbusAddress Modbus device address modbusRegister address of Modbus register to be read Examples MR 1 10 Reads register 10 of the Modbus device with address 1 MR 192 168 1 20 502 10 Reads register 10 of the Modbus TCP device with IP address 192 168 1 20 and TCP port 502 Modbus Wr...

Page 84: ...ss 1 using the Modbus writing command 3 MW 1 10 100 4 Writes the value 100 in register 10 of the Modbus device with address 1 using the Modbus writing command 4 MW 192 168 1 20 502 10 100 Writes the value 100 in reegister 10 of the Modbus TCP device with IP address 192 168 1 20 and TCP port 502 using the Modbus writing command 3 MW 1 10 100 4 Writes the value 100 in reegister 10 of the Modbus TCP ...

Page 85: ...itan device SR 2 0 Deactivates relay 2 of the Titan device SEND SMS command Syntax SS telephoneNumber message Description Sends an SNS to a specific telephone number Parameters telephoneNumber Telephone number where the SMS is to be sent to message message to be sent Example SS 666123456 Alarm activated Sends an SMS to the number 666123455 with the text Alarm activated SEND EMAIL command Sintasix ...

Page 86: ...xample SS alarmas gmail com Alarm activated Sends an email to the email address alarmas gmail com with the subject Alarm activated PAUSE command Syntax PA seconds Description Makes a pause in the management of the Titan scripts Parameters seconds length in seconds of the pause Example PA 5 Creates a 5 second pause Comando DATE Syntax DA Description Pauses the Titan script management process Parame...

Page 87: ...ondition AND logic condition OR logic condition add subtract multiply divide operators equal to condition more than condition less than condition more than or equal to condition less than or equal to condition parenthesis to encompass expressions In the ACTION1 and ACTION2 field we must use the MW SR SS action commands although we can also use MR for more flexibility this will become clearer in th...

Page 88: ...seful when the user wants to send SMS message alerts or email alerts as this avoids continuous repeated messages Continuous execution In this case the action MW 1 10 MR 2 3 is executed whenever the condition MR 2 2 18 is true Do NOT use this option if SMS or emails will be sent as this will result in continuous messages being sent Execution upon changes In this case the action MW 1 10 MR 2 3 is ex...

Page 89: ...gister 10 of the Modbus device with the address 1 is greater than 100 Write the value 1 in register 20 of the Modbus device with address 2 Otherwise Write the value 0 in register 20 of the Modbus device with address 2 EXAMPLE 2 If register 10 of the Modbus device with the address 1 plus register 11 of the Modbus device with address 1 is greater than 100 Write the value 1 in register 20 of the Modb...

Page 90: ...s greater than 10 Write in register 7 of the Modbus device with address 1 the current value of register 1 in the Modbus device with address 1 Otherwise Write in register 7 of the Modbus device with address 1 the current value of register 2 in the Modbus device with address 1 EXAMPLE 4 Always since the condition 1 1 will always be true Write in register 10 of the Modbus device with address 2 the cu...

Page 91: ... the Modbus device with address 1 register 11 of the Modbus device with address 1 is greater than 100 OR if register 12 of the Modbus device with address 1 is greater than register 100 of the Modbus device with address 2 Write in register 20 of the Modbus device with address 1 the current value of register 15 of the Modbus device with address 2 multiplied by 3 plus 1 Otherwise Write in register 20...

Page 92: ...ess 1 is greater than 10 Send an SMS with the text new value value read from register 16 del of the Modbus device with address 1 to the telephone number 666123456 AND AFTER Write in register 17 of the Modbus device with address 1 the value 1 Otherwise Write in register 17 of the Modbus device with address 1 the value 0 EXAMPLE 9 If register 10 of the Modbus device with address 1 is equal to 1 Send...

Page 93: ...ster 15 of the Modbus device with address 1 is greater than 10 CONTINUOUSLY Activate the Titan device s internal Relay 1 AND AFTER pause for 5 seconds AND AFTER Deactivate the Titan device s Relay 1 The difference between example 10 and 11 lies in the symbol This indicates that the action is continuously executed This means that in example 10 ACTION1 is executed just once when the IF condition is ...

Page 94: ...4 in Modbus device with address 1 is greater than 10 Send an email with the text New alarm detected Value value read from register 4 of the Modbus device with address 1 to the email jgallego matrix es Additional Notes Remember that if the command SE is used to send emails the device must be configured beforehand using the menu Other Email configuration ...

Page 95: ...onsole Below you can find a table with the Modbus address for the Titan registers The Modbus commands that are permitted are 0x03 to read and 0x10 to write Register ID R W Possible Values Description 1 R 0 32635 Firmware version 2 R 0 32635 Firmware subversion 3 R W 0 1 Relay 1 0 relay open 1 relay activated 4 R W 0 1 Relé 2 0 relay open 1 relay activated 5 R 0 1 Digital input status 0 input to GN...

Page 96: ...or sending AT Commands via Modbus TCP The process is simple and the best way to understand it is using a practical example For example imagine we want to execute the command AT CSQ to obtain the network coverage 1 First we must write the AT command in ASCII code using the registers 100 and onwards Register ID Value Description 100 65 ASCII for letter A 101 84 ASCII for letter T 102 43 ASCII for ch...

Page 97: ...tion 99 28 Size of response to command 4 Finally we must read the 28 registers where the response is contained register 500 onwards Register ID Value Description 500 65 A 501 84 T 502 43 503 67 C 504 83 S 505 81 Q 506 13 r 507 13 r 508 10 n 509 43 510 67 C 511 83 S 512 81 Q 513 58 514 32 space 515 49 1 516 54 6 517 44 518 57 9 519 57 9 520 13 r 521 10 n ...

Page 98: ...t in order to use this characteristic to send SMS messages the AT command is AT MTXTUNNEL SMS phone message as previously outlined in this guide Procedure for receiving SMS messages The process for receiving SMS messages via Modbus TCP is very simple The PLC should periodically check register 1000 If the value read is 1 this indicates that there is a new SMS message which can be read from regsiter...

Page 99: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 99 http www mtxm2m com Subject to changes without prior notice ...

Page 100: ...red beforehand to be able to receive emails This is done from this section by configuring the SMTP server Enabled Select this box if you wish to activate this option Smtp server Indicate the address or DNS or the SMTP server for example smtp gmail com smtpout secureserver net etc Smtp Port TCP port of the SMTP server Authentication select this box if the SMTP server requires authentication usually...

Page 101: ... that the router should be reset in order for the changes to take effect Remember that if you use a Gmail SMTP server you may have to activate certain configurations in your account in order to be able to send emails from an IOT device To do this you must carry out the following actions 1 Activate the option http www google com settings security lesssecureapps 2 Activate http www google com accoun...

Page 102: ...this box if you wish to activate the Titan router s SNMP service UDP port The standard UDP port for SNMP is 161 but this can be changed here Community The password required to execute SET and GET commands Custom OID This option allows you to change the Enterprise Product OID of the default value 45711 1 1 if you wish to tune this to your business values Traps UDP port This option allows you to spe...

Page 103: ... being used etc It is also possible to find out the status of the router s relays as well as change their statuses The same is possible with digital inuts and pulse counters An interesting option can be found in the section Action Here you will see that two actions are possible Firstly you can reset the router remotely Secondly you can execute an AT command remotely via SNMP writing in the corresp...

Page 104: ...a MTX Router Titan User Manual Rel3 00 3 09 Page 104 http www mtxm2m com Subject to changes without prior notice AN8 Router Titan Modbus to SNMP Gateway pdf AN10 Router Titan sending SMS Emails Traps with ModbusTCP pdf ...

Page 105: ...h different sensitivity modes SMS This option activates the sending of SMS messages in the event of detected movement Call This option activates the telephone call option in the even of detected movement Phone numbers List of numbers separated by semi colon to which SMS messages will be sent and phone calls will be made Text SMS Alarm On Text of the SMS alarm Pause between alarms This field indica...

Page 106: ...l Rel3 00 3 09 Page 106 http www mtxm2m com Subject to changes without prior notice Once the configuration is complete press the SAVE CONFIG button to save the changes Remember that the router should be reset in order for the changes to take effect ...

Page 107: ...s firewalls etc and especially when using SIM cards that use IP addresses in the range 10 x x x Enabled Select this box if you wish to activate the OpenVN service in Server mode Mode This option allows you to establish the connection mode for the VPN service Always On will keep the VPN active at all times Under Request will activate the VPN for the time you require This option could be used in tim...

Page 108: ...o access remotely the devices connected to the router s Ethernet port Do not activate this option if you only want to access the router and the IP RS232 485 USB gateways controlled by the router Necessary files for OpenVPN In order to be able to use the MTX Router Titan devices as an OpenVPN server you will need to create and update the following files ca crt certificate of authenticity server crt...

Page 109: ... addresses in the range 10 x x x Enabled Select this box if you wish to activate the OpenVN service in Client mode Mode This option allows you to establish the connection mode for the VPN service Always On will keep the VPN active at all times Under Request will activate the VPN for the time you require This option could be used in times of maintenance for example If used to activate the VPN servi...

Page 110: ...uter Titan devices as an OpenVPN client you will need to create and update the following files ca crt certificate of authenticity client crt server certificate and client key server private key Towards the bottom of the screen you will see that you can download example files These must only be used in test mode In real applications you should always generate your own certificates Additional Notes ...

Page 111: ...S 4 Via Telnet Remote Console via 3G Ethernet or Wi Fi 5 Via Webserver via 3G Ethernet or Wi Fi 6 Via Modbus TCP via 3G Ethernet or Wi Fi AT commands can be sent to the router under your responsibility The accepted commands are those indicated in the Cinterior EHS5 AT Commands manual as well as extra commands listed below AT MTXTUNNEL REBOOT Action Resets the Titan router AT MTXTUNNEL VERSION Acti...

Page 112: ...otix external device distance sensor is connected AT MTXTUNNEL TRAP OID myMessage mySeverity Action Allows an SNMP Trap to be sent with a specific OID and the corresponding message and severity Example AT MTXTUNNEL TRAP 1 3 6 1 4 1 45711 1 1 11 1 1 myMessage 5 AT MTXTUNNEL SMS telephoneNumber message Action Allows an SMS message to be sent to a specific number Example AT MTXTUNNEL SMS 34677123456 ...

Page 113: ...tes Action If the VPN OpenVPN Client section is configured as an on demand OpenVPN service the service can be activated in client mode for the specified time Example AT MTXTUNNEL OVPNC 5 This example activates the VPN for 5 minutes AT MTXTUNNEL RESETCOUNTER 1 Action If the digital input is used as a pulse counter the count can be reset to the value specified in the command Example AT MTXTUNNEL RES...

Page 114: ...egisters of a device where ModbusAdd Modbus device address 1 255 or IP address port FirstRegisterAdd address of the first register to be read 0 65535 numWords number of Modbus registers to read 1 64 command command to read Modbus 3 or 4 Example AT MTXTUNNEL GETMODBUS 192 168 1 200 502 1 1 3 3 sent from a web configured environment can also be sent via SMS or Remote Console Telnet obtaining the val...

Page 115: ...te command 6 or 16 data1 dataX values of the Modbus registers to be written Example AT MTXTUNNEL SETMODBUS 1 3 16 10 11 12 13 14 15 sent from the configuration environment This writes in the Modbus RTU device with address 1 starting in register 3 and using the Modbus writing command 16 the values 10 11 12 13 14 and 15 Example AT MTXTUNNEL SETMODBUS 192 168 1 202 502 3 16 10 11 12 13 14 15 sent fro...

Page 116: ...formation of the telephony cell used Can be useful as it obtains an approximate GPS position For the remaining standard commands please consult the Siemens Gemalto AT command manual for information regarding the format and functionality of each command containted in the EHS6 module If you require the documentation you can request it at the email address gsmsupport matrix es ...

Page 117: ...uded in the Titan routers If you require a peculiar characteristic that cannot be found in the current characteristics let us know at gsmsupport matrix es Depending on the size of the project this could be included as a plugin for free Given that the plugins are independent utilities when a copy of the Titan configuration is created it is not necessary for the plugin section to be replicated ...

Page 118: ...d ports of the remote devices to create the connection A typical representation would be as follows However your GSM operator does not allow this as it blocks all incoming connections to modems What you can do with the Titan router is the following Sentido del establecimiento de la conexión TCP IP MTX ROUTER TITAN RS232 MTXTunnel Equipo con Puerto Serie RS232 de envío de info RS232 RS232 MTXTunnel...

Page 119: ...trate this with an example In this case we must configure the GPRS modems MTX Tunnel to work in client mode MTX_mode client and so that an identificative chain is sent so that the Titan knows which MTX Tunnel each connection corresponds to For example we can make MTX Tunnel 1 send A 000001 MTX_IDClient A 000001 as the identificative chain and MTX Tunnel devices 2 and 3 will send A 000002 and A 000...

Page 120: ... Subject to changes without prior notice Once connected to a socket the data sent by the PC will be received by the Titan an then reset by the corresponding socket to the MTX Tunnel to which we wish to connect Once this data reaches the MTX Tunnel device it will be resent by the serial port ...

Page 121: ...figured in the Titan device that restarts the external device that has caused the failure either by carrying out a standard reset or by cutting off its power supply for a specific period of time Enable Plugin This option activates the plugin Relay1 enable This option configures Relay 1 so that it is activated when a block is detected in a connected device Period This field specifies the number of ...

Page 122: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 122 http www mtxm2m com Subject to changes without prior notice ...

Page 123: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 123 http www mtxm2m com Subject to changes without prior notice Annex 1 Basic Example Scenarios Configurations ...

Page 124: ...outer Titan 3G mini router Example configuration ready for use You can easily load the example from the router s web configuration environment from the menu Other Backup Examples Details 1 After the configuration is loaded in your router you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the m...

Page 125: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 125 http www mtxm2m com Subject to changes without prior notice ...

Page 126: ...ation from the TCP port 80 to the TCP port 8080 so that there are not conflicts with the camera port We also need the remote configuration to have access to the Internet from any IP address Therefore only the IP addresses 200 1 2 3 and 200 1 2 4 corresponding to the central offices will be able to access the IP camera SIM cards with fixed IP address will be used Solution MTX Router Titan 3G mini r...

Page 127: ...AT In other words we need to redirect traffic that arrives in the router s TCP80 port to the internal IP address and TCP port belonging to the camera i e to the IP 192 168 1 70 4 Remember that in order to work the camera s IP address should be in the range of the router s LAN IP address and we should specify the camera s Gateway IP address with the router s LAN IP address In this example it would ...

Page 128: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 128 http www mtxm2m com Subject to changes without prior notice ...

Page 129: ...thernet device that is connected to the router we must only provide them with Internet access We have to be able to access the router s configuration remotely in the standard TCP port 80 A SIM card with a dynamic IP address will be used We do not want to use services such as DynDNS or No IP therefore we need to be able to obtain the router s IP address at any time via a missed call or SMS Via this...

Page 130: ...Server Other Sms Control 3 Remember that we must specify the PLC s Gateway IP address with the router s LAN IP address In this example it would be 192 168 1 2 4 If you wish to obtain the router s IP address via a missed call ensure that the SIM card inside the router has voice calling services activated and not only data services If voice calling is restricted it will only be possible to obtain th...

Page 131: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 131 http www mtxm2m com Subject to changes without prior notice ...

Page 132: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 132 http www mtxm2m com Subject to changes without prior notice ...

Page 133: ...ress of 192 168 1 1 Several tablets will also connect to the router via Wi Fi DHCP which will need to be able to connect to the Ethernet device which is connected to the router for maintenance tasks although Internet accesss must also be blocked for these Only the Ethernet device should have Internet access Solution MTX Router Titan 3G mini router Configuration example ready for use You can easily...

Page 134: ...iguration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings Wifi Basic Settings Wifi DHCP Server 3 Remember that in order to work the PLC s IP address should be in the range of the router s LAN IP address and we should specify the PLC s Gateway IP address with the router s LAN IP address In this example i...

Page 135: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 135 http www mtxm2m com Subject to changes without prior notice ...

Page 136: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 136 http www mtxm2m com Subject to changes without prior notice Annex 2 Advanced Example Scenarios and Configurations ...

Page 137: ...port 502 The Ethernet device has a local IP address of 192 168 1 70 We have to be able to access the router s configuration remotely in the standard TCP port 80 We want to be able to remotely access the device SIM cards with a dynamic IP address will be used therefore we will use the DynDNS or No IP services Solution MTX Router Titan 3G mini router Configuration example ready for use You can easil...

Page 138: ... you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings Firewall Nat Other DynDNS 3 Remember that in order to work the Gateway IP address of the Ethernet device should be specified along with the router s LAN IP address In this example it would be 192 168 1 2 ...

Page 139: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 139 http www mtxm2m com Subject to changes without prior notice ...

Page 140: ...re we want to use DHCP in the Ethernet port We need to be able to access the router s configuration remotely via the standard TCP port 80 The router will be listening in the TCP port 20010 to create a transparent 3G RS232 gateway and to be able to remotely access the device via the serial port RS232 with the configuration 115200 8 N 1 Solution MTX Router Titan 3G mini Configuration example ready f...

Page 141: ... router you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings LAN DHCP Serial Settings Serial Port 1 3 With the 3G RS232 gateway everything that is sent to the router s TCP port 20010 will be redirected to the device s serial port RS232 and vice versa ...

Page 142: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 142 http www mtxm2m com Subject to changes without prior notice ...

Page 143: ... to send data to the Cloud The Ethernet device has the LAN IP address 192 168 1 70 Another device in this case with an RS232 serial port will be connected to the router s RS232 port This device will manage a series of alarms and must be able to send them via SMS using standard AT commands from any GSM modem Solution MTX Router Titan 3G mini Configuration example ready for use You can easily load t...

Page 144: ... 2 Check the configuration in the menus Wan Basic Settings LAN DHCP Serial Settings Serial Port 1 3 Look carefully at the configuration in Serial Settings Serial Port 1 You will see that the router redirects all traffic received in the serial port to the internal GSM module therefore the AT commands that are sent through it must be appropriate for the Cinterion EHS5 module Consult the commands AT ...

Page 145: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 145 http www mtxm2m com Subject to changes without prior notice ...

Page 146: ... MTX Router Titan 3G mini Configuration example ready for use003A You can easily load the example from the router s web configuration environment from the menu Other Backup Examples Details 1 After the configuration is loaded in your router you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in th...

Page 147: ...or notice 5 If you use the MTX Router Titan 3G mini device you will likely need to use a miniUSB USB adaptor 6 Remember that the USB device must be connected to the router before the MTX router is connected to a power source The MTX router will not detect the USB device correctly if it is connected after the power supply ...

Page 148: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 148 http www mtxm2m com Subject to changes without prior notice ...

Page 149: ...e This activation deactivation can be done via the router s webserver or via SMS The text will be ON to activate the relay and OFF to deactivate it Finally we need to be able to carry out a reset of the external device s power supply without needing to send two SMSs For this we will send the text RESET which will deactivate the relay for three seconds Solution MTX Router Titan 3G mini Configuratio...

Page 150: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 150 http www mtxm2m com Subject to changes without prior notice ...

Page 151: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 151 http www mtxm2m com Subject to changes without prior notice ...

Page 152: ...t 80 redirecting the external TCP port 8080 since we need to be able to access the router s webserver configuration also located in the TCP port 80 SIM cards with fixed IP address will be used The temperature that is read must be send every 15 minutes to a webserver The webpage to which it will be sent is http www metering es json set asp data In the event that the temperature that is read is grea...

Page 153: ...nfiguration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings y Firewall NAT Serial Settings Serial Port1 External Devices Logger Configuration External Devices Temperatura Sensor Other Time Servers 3 If you need a webserver to carry out testing write to us at gsmsupport matrix es and request a testing ac...

Page 154: ...RS232 output The Maxbotix output will be installed at the top of the grain silo to measure the distance When a distance greater than 6 meters is detected this means the volume is very low and an SMS alert must be sent to three different telephone numbers as well as activating a warning light via a relay Additionally the grain silo level must be sent every 12 hours to a webserver The web address wi...

Page 155: ...efault username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings Wifi Basic Settings Wifi DHCP Server Serial Settings Serial Port1 External Devices Logger Configuration External Devices DistanceTemperatura Sensor Other Relay1 Other Time Servers 3 If you need a webserver to carry out testing write to us at gsmsupport matrix es and...

Page 156: ...er via HTTP GET using a JSON object after each reading but it must be able to store up to 1000 readings in its flash memory in case of GPRS communication failure These will be send upon restoration of the service For each meter a JSON string will be sent where the meter that is read will be indicated with an identifier the Modbus address Finally the router should provide Internet access to a netwo...

Page 157: ...ck the configuration in the menus Wan Basic Settings Lan Basic Settings Firewall Nat Serial Settings Serial Port1 External Devices Logger Configuration External Devices Generic Modbus RTU Other Time Servers 3 If you need a webserver to carry out testing write to us at gsmsupport matrix es and request a testing account in the test server site www metering es 4 Remember that in section 4 5 4 of this...

Page 158: ...where the meter is installed Therefore we will take advantage of the client s ADSL router which has a fixed IP address to access the meter s data The ADSL router s LAN IP address is 192 168 1 1 and the port to be used is the TCP 20010 port The energy provider Iberdrola Endesa etc should also be able to access the meter via a GSM data call This call with take priority over the IP connection made wi...

Page 159: ... to accept CSD calls when the router is in fixed GPRS mode It will not be possible when it is working in 3G mode 4 Since we want to use an existing ADSL router we must create an NAT mapped from at least one TCP port from the ADSL router to the MTX Router Titan 3G mini In this example case the MTX Router Titan 3G mini is listening out to create an IP RS232 gateway in the TCP20010 port A NAT should ...

Page 160: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 160 http www mtxm2m com Subject to changes without prior notice ...

Page 161: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 161 http www mtxm2m com Subject to changes without prior notice ...

Page 162: ...meter s LAN IP address is 192 168 1 70 On the other hand we have an electricity meter with an RS232 port with the configuration 9600bps 8N1 The data from this meter should be accessed using a transparent GPRS RS232 gateway for which we will use the TCP20010 port The energy provider Iberdrola Endesa etc must also be able to access the electricity meter via a typical GSM CSD data call When the opera...

Page 163: ...r Backup Examples Details 1 After loading the configuration on your router you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings LAN Basic Settings Firewall NAT Serial Settings Serial Port 1 3 Remember that the router can only be configured to accept CSD calls when th...

Page 164: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 164 http www mtxm2m com Subject to changes without prior notice ...

Page 165: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 165 http www mtxm2m com Subject to changes without prior notice ...

Page 166: ...to read 2 analog inputs 4 20mA The module with address 3 has 8 relay outputs We can change Relay1 in module 3 by writing 1 in register 1 when the digital inputs 1 2 and 3 registers 1 2 and 3 in module 1 are activated all three of them have the value 1 Also Relay2 in module 3 will be changed writing 1 in register 2 when the digital entries 4 or 5 registers 4 and 5 in module 1 are not activated or w...

Page 167: ...s web configuration environment from the menu Other Backup Examples Details 1 After loading the configuration on your router you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings LAN Basic Settings Serial Settings Serial Port 1 Other Titan Scripts ...

Page 168: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 168 http www mtxm2m com Subject to changes without prior notice ...

Page 169: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 169 http www mtxm2m com Subject to changes without prior notice Details 2 ...

Page 170: ...th address 3 Condition If register 4 of the device with address 1 is equal to 0 OR If register 5 of the device with address 1 is equal to 1 OR If register 1 of the device with address 2 is greater than or equal to 1 If true write 1 in register 2 of the device with address 3 If false write 0 in register 2 of the device with address 3 Condition If register 2 of the device with address 2 is greater t...

Page 171: ...ess will be used We must be able to obtain the router s IP address via a missed call from either of the following numbers 666123456 and 666123457 The router must be configured to detected possible GSM inhibitors When a possible detection is made a relay connected to a siren must be activated and if the inhibitor signal is weak given it is not too close an SMS alert must be sent and a GSM call made...

Page 172: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 172 http www mtxm2m com Subject to changes without prior notice ...

Page 173: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 173 http www mtxm2m com Subject to changes without prior notice ...

Page 174: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 174 http www mtxm2m com Subject to changes without prior notice ...

Page 175: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 175 http www mtxm2m com Subject to changes without prior notice ...

Page 176: ...d the readings in real time in JSON format via HTTP GET to Platform 1 On the other hand the router will send a file once a day with the readings to Platform 2 via FTP The file will have a name of the format IMEI year month day txt Registers 1 registers 1 10 2 register 20 and 30 3 registers 21 25 4 registers 100 105 and 5 registers 1 5 and 20 25 All will use the Modbus read command 0x03 We also nee...

Page 177: ...Examples Details 1 After loading the configuration on your router you can access the router s configuration with the default username and password admin and admin and the IP address 192 168 1 2 2 Check the configuration in the menus Wan Basic Settings Serial Settings Serial Port 1 External devices Logger Configuration External Devices Modbus RTU 3 Remember that readings are not taken immediately u...

Page 178: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 178 http www mtxm2m com Subject to changes without prior notice ...

Page 179: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 179 http www mtxm2m com Subject to changes without prior notice ...

Page 180: ...e Slave Modbus simulator For example the following figure shows the creation of this example s 5 devices with addresses 1 to 5 and the corresponding registers The responses read and collected by the Titan device and then sent to a Web platform in this example the test platform www metering es will have the following format as shown in the External Modbus RTU section of this manual ...

Page 181: ...eated in the remote FTP server and the following content shown below the previous JSON registers grouped together in an easy to mange txt file Details 3 For firmware versions up to 1 07 Titan routers can read data types UNSIGNED WORD 2 bytes For versions 1 08 or later they can also read data types DOUBLE WORD 4 bytes FLOAT 4 bytes COIL 1 bit and INPUTS 1 bit For example we can configure the emulat...

Page 182: ...ior notice If we wish to read registers 1 2 and 3 from device 1 SlaveWORD registers 2 4 and 6 from device 2 SlaveDWORD and registers 2 4 and 6 from device 3 SlaveFLOAT as well as 10 bits starting from bit 1 from device 5 SlaveCOIL and 7 bits starting from bit 2 from device 6 INPUTS the configuration would be as follows ...

Page 183: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 183 http www mtxm2m com Subject to changes without prior notice Annex A General description of Hardware connections ...

Page 184: ...nections Introduction Below you will see a basic connection diagram showing the MTX Router Titan 3G device s connection terminals Note that you can power the router with both alternating voltage 90 240VaC or direct voltage 7 50Vdc USB Ethernet COM1 RS232 RS485 GND CTS RTS RX TX D D COM3 RS232 TX RX GND 90 240Vac NO COM NC Relay1 NO COM NC Relay2 SW2 SW1 COM2 RS232 GND RX TX VCC GND Vcc 7 50Vdc 5V ...

Page 185: ...hanges without prior notice 1 The COM1 port can be configured as an RS232 or RS485 port By default it is configured as an RS232 port To change this to an RS485 port you must 1 Place switches 1 and 2 to the ON position from DIP Switch SW2 see last diagram 2 Specify RS485 in the environment configuration ...

Page 186: ... webserver in JSON format Modem control via AT commands Hayes TS 27 007 TS 27 005 DynDNS NoIP and Private DNS services Remote relay control GSM cell positioning Programmable autoreset Internal configuration webserver all logos and pictures can be customized by user Operating status LEDs NTP time date synchronization User permissions and configuration backup Remote firmware upgrade Supply voltage r...

Page 187: ...G device s connection terminals VCC can have a value between 7 and 50Vdc The power supply must allow consumption peaks of 1 5A In the following table the available connections in the MTX Router Titan 3G mini s DB15 connector are shown Female DB15 Connector Use Female DB15 connector Use 1 CANH 9 COM3__RX 2 COM1__RX 10 VCC_OUT 2 3 COM1__TX RS485_D 1 11 RELAY1_COM 4 COM3__TX 12 COM2__TX 5 1 WIRE BUS ...

Page 188: ...put VCC_OUT PIN_10 that can be configured to a 3 3V or 5V output 3 The Titan mini device has a digital input that is shared with the RX pin belonging to the COM2 port As a result if you wish to use the digital input you cannot use the COM2 port and vice versa TO use the digital input ensure that switch 5 is in the ON position The digital input will change status if PIN_13 is disconnected in which ...

Page 189: ...JSON format Modem control via AT commands Hayes TS 27 007 TS 27 005 DynDNS NoIP and Private DNS services Remote relay control GSM cell positioning Programmable autoreset Internal configuration webserver all logos and pictures can be customized by user Operating status LEDs NTP time date synchronization User permissions and configuration backup Remote firmware upgrade Supply voltage range o DC inpu...

Page 190: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 190 http www mtxm2m com Subject to changes without prior notice Annex B Generic emulation software for virtual serial ports ...

Page 191: ... for 64 bit platforms Emulation software for serial ports to TCP IP must be used if you have old software for connecting serial devices that only allows you to connect to these devices via a COM serial port This software allows you to create virtual COMs COM1 COM2 COM3 etc on your PC that in reality are directed to a specific IP address or TCP port You can download the software from the following ...

Page 192: ...3 09 Page 192 http www mtxm2m com Subject to changes without prior notice 2 Select the option Connector 3 Select the number of the virtual COM that we want to use For example COM10 4 Click Finish The virtual COM that has been created will appear in the list ...

Page 193: ...lowing screen we indicate the remote IP address of our MTX device We can input a numeric IP if we use a SIM with fixed IP address or because we have obtained the current IP address via SMS or missed call or a DNS if we use the DynDNS service We also select the TCP port that the MTX is listening in 20010 by default Finally we select the virtual COM port that we have previously created In this examp...

Page 194: ...ave the COM10 port connected to our MTX device 8 The last step is to access our control application and select the COM10 port as the communication port Now you can remotely access your serial devices Remember that the modem s serial port configuration bauds data bits etc must be established in the config txt file as explained in this manual ...

Page 195: ...Matrix Electrónica MTX Router Titan User Manual Rel3 00 3 09 Page 195 http www mtxm2m com Subject to changes without prior notice Annex C Release notes of firmware versions ...

Page 196: ...es from the WAN interface 3G This means that a different port can be specified which allows NAT to be carried out from the TCP port 80 to internal devices that use this port V1 04 Allows the Wi Fi channel to be chosen to improve performance depending on location Sending data via FTP is added as an option to the Logger Improvements in the IP Serial gateway performance V1 05 Use of the Hardware watc...

Page 197: ...via Modbus TCP protocol V1 09 FTDI and ACM connections to USB devices permitted V1 10 Added control to the internal GPS module in the MTX Router Titan 3G device Added possibility of sending emails either by AT command from external devices or automatically using Titan Scripts Improvements in the Logger to be able to send data to third party platforms GroveStreams for example V1 11 Improvements in ...

Page 198: ...s in firewall allowing specific IP addresses to be authorized V2 00 Improvements in OpenVPN faster speeds V2 01 No NAT plug in included Improvements in Titan Scripts new commands V2 02 New MTX Router Titan models only ETH and Wi Fi as well as new MTX Router Titan mini models only ETH and Wi Fi i e new devices without the GSM communication module Improvements in Titan Scripts supporting Modbus TCP ...

Page 199: ... there is a complete guarantee that the GSM network will be reached after restarting The process could however take a few seconds longer than normal as a result IP Serial gateways can be established at the same time as an External Modbus RTU device or script For example the Titan router can be configured to take readings from a Modbus RTU device via a serial port as well as connect remotely to the...

Page 200: ...g of TRAPS via AT commands and Modbus TCP now available Sending of TRAPS from Titan Scripts now available Application Note available for this feature V3 00 3 07 Increased possibilities to send the internal logger to web platforms Now available TCP socket HTTP GET HTTPS GET HTTP PUT HTTPS PUT and GroveStreams Improvements in the internal SNMP server New more complete MIB Added a timeout of 900 seco...

Reviews: