Example Scenario 2.4
Configuration to remotely access a USB device via Internet using a 3G router.
Details of the example scenario:
We have a device with a USB port (a weather station) which we want to access remotely to
extract the data from the internal datalogger. The driver is of the standard USB FTDI type.
The router will be listening in the TCP port 20014 to create a 3G-USB gateway and remotely
access the device via USB port.
For simplicity, a SIM card with fixed IP address will be used in this example, although the IP
address can be obtained via SMS, or you can use a missed call as seen in previous
examples.
Solution:
MTX-Router-Titan-3G-mini
Configuration example ready for use003A
You can easily load the example from the router’s web configuration environment from the menu
“Other>Backup / Examples”.
Details.
1.- After the configuration is loaded in your router, you can access the router’s configuration with the
default username and password: “admin” and “admin”, and the IP address“192.168.1.2”
2.- Check the configuration in the menus “Wan>Basic Settings”, “Serial Settings>Serial Port 5”.
3.- Remember that in order for the gateway to work, the driver that the device uses must be USB FTDI
or ACM. For other USB devices, get in touch with us at
.
4.- A USB FTDI device emulates a serial device via USB. It is very important that you check the section
“Serial Settings>Serial Port 5>Timeout ms” and the timeouts section, if this exists, in your control
software.
MTX-Router-
Titan-3G-mini
3G
USB
ADSL
Access to a USB device via Internet
Weather station /
datalogger with a
USB port