![Titan Atrato 710 Instruction Manual Download Page 6](http://html1.mh-extra.com/html/titan/atrato-710/atrato-710_instruction-manual_1119313006.webp)
The Atrato can be operated entirely from a computer using the USB connection but this
may not be acceptable in many situations where remote operation or further functions
are required. The unit will work with systems from Windows XP onwards. The maximum
connector cable size is 2.5mm (22-14AWG), for ease of assembly we recommend 1mm
maximum. Care should be taken when terminating the wires as the conductors should
be stripped to 4 to 5mm maximum and the wire ends must be pushed fully into the
connector before tightening. These cables pass through a slot cut in the aluminium
housing please ensure that no bare conductors are clear of the surface of the connector
strip prior to closing the housing.
3 Electrical
Atrato Connector Assignments
Pin
No
Label Function
1
Relay NO
Isolated relay contact; normally closed contact 24V 100mA
2
Relay Common
Isolated relay contact; change over contact 24V 100mA
3
Relay NC
Isolated relay contact; normally open contact 24V 100mA
4
4-20mA
Analogue current (4-20mA) output (reference to 0V)
5
0-5/10V
Analogue voltage (0-5/10V) output (reference to 0V)
6
PNP
Output 1 open collector PNP OR Input 1 (5-24V dc) e.g. switch to pin 9
7
NPN
Output 2 open collector NPN OR Input 2 (5-24V dc) e.g. switch to pin 8
8
0V
External ground; common for PNP, NPN and Analogue outputs
9
+9 -24V dc
External power; 9V ~24V (> 12V for Analogue output)
6
= Operates on External Power
or
USB = Operates on External Power only
Summary of Contents for Atrato 710