The chart below shows the various display messages for various operating functions.
During operation only one message will be shown for each parameter.
Parameter Value Notes
Function
Flow rate
2.5000
Litres per minute
Units selected in configuration
Filtered flow rate 2.4981
Litres per minute
This will lag flow rate
Total
16.95
Litres
Total passed since last reset
Pin 6.
Off
Pin not being used
83.33Hz
Output Pulses (2000 per Litre)
Frequency output for current flow rate @
2000 pulses/Litre
On
Will turn off when rate below 2.7 Flow switch set to 3 L/Min 10% -ve flow.
Off
Will turn on when rate above 3.3 Flow switch set to 3 L/Min 10% +ve flow.
Forward
Direction of flow
Reverse flow tab selected
Low
Input logic level
Left push button selected will momentarily
show high when remotely operated
Low
Input logic level
Right push button selected will momentarily
show high when remotely operated
Pin 7.
Off
Pin not being used
83.33Hz
Output Pulses (2000 per Litre)
Pulse output selected
On
Will turn off when rate below 2.7 Flow switch set to 3 L/Min 10% -ve flow.
Off
Will turn on when rate above 3.3 Flow switch set to 3 L/Min 10% +ve flow.
Forward
Direction of flow
Reverse flow tab selected
High
Input logic level
Left push button selected will momentarily
show low when remotely operated
High
Input logic level
Right push button selected will momentarily
show low when remotely operated
Relay
Off
Relay not being used
On
Will turn off when rate below 2.8 Flow switch set to 3 L/Min 10% -ve flow.
Off
Will turn on when rate above 3.4 Flow switch set to 3 L/Min 10% +ve flow.