PUF+ Operator’s Manual
Tisch Environmental
22
Reviewing Data
When using either the VIEW CURRENT SAMPLE or VIEW PAST SAMPLE menu items, a
series of screens will be displayed that contain data collected during the timer event. Switch
between screens us the UP and DOWN ARROW keys. Use the ESC key to return to the
DATA menu.
TIMER SETUP
04-20-07 12:09:11
MODE: TIMER
STR:04-20-07 10:30:00
STP:04-20-07 11:30:00
DURATION: 01:00:00
REPEAT: 00:00:00
The first screen (shown above) displays the timer setup data. This includes the timer mode
(either TIMER or REMOTE), the set start date, the set stop date, the set duration of the timed
event, and the repeat interval.
TIMER DATA
04-20-07 12:09:11
MODE: TIMER
STR:04-20-07 10:30:00
STP:04-20-07 11:30:00
DURATION: 01:00:00
The second screen (shown above) displays the timer actual data. This includes the actual
start date, the actual stop date and the actual duration. Please note that if a power failure
occurs, then it is possible that the values will not match the data from the TIMER SETUP
screen.
FLAGS
COMPLETED: Y
EXECUTING: N
PAUSED: N
ABORTED: N
EXPIRED: N
POWERFAIL: N
Qstd: N