22
E
N
G
L
I
S
H
The Cyclone Feed System
-
refer to the Parts Diagram (pages 24-25)
1. Remove the
Screw
(19) and
Washer
(22) to remove the
Feeder Sprockets
(21 and 20).
2. Remove four
Screws
(19) from the
Feeder Bottom Plate
(18).
3. The feed drive parts are now accessible for inspection or repair.
4. Reassemble in the reverse order.
Tuning the Response Trigger Rate of Fire
Use a small screwdriver to adjust the Flow Control to the desired speed. Turning the screw
clockwise slows the rate of fire. Turning the screw counterclockwise increases the rate of fire
(Figure 25).
If tuning the Response Trigger as
described above produces little or
no change in the rate of fire, go to
Resetting the Flow Control
below.
If the trigger remains easy to pull after adjusting the flow control, there may be a leak in the
system, go to
Check for Leaks
below.
Resetting the Flow Control
1. With no paintballs in the Hopper, see
Unloading Your Marker
steps 1-6 (page 10),
begin adjusting rate of fire by turning flow control clockwise completely. Do not over
tighten or damage will occur.
2. In a safe direction, fire 2 to 4 ‘air only’ shots. The Trigger should become very hard
to pull, or even unable to be pulled. If this occurs, the Response Trigger system is
functioning properly. Go to step 3. If Trigger does not become hard to pull, go to
Check
for Leaks
.
3. While firing the marker in a safe direction (air only shots), slowly turn the flow control
counterclockwise until the desired rate of fire is achieved.
Check for Leaks
If you suspect that there may be a leak
in the system,
double check installation
making sure all fittings are tight and
O-Rings are properly seated. If you
need to disassemble in order to check
that all fittings are tight and O-Rings
are properly seated, follow the
A-5
Marker Disassembly/Reassembly
Instructions
(page 17).
Do NOT disassemble the marker while it
is pressurized with air.
If a problem still exists, call the
Tippmann Service Department at
1-800-533-4831.
Figure 25: Adjust Flow Control with screwdriver
Refer to the dark arrow in Figure 25. When reassembling the lower
Receiver to the upper Receiver, make sure the Cylinder Fitting (with
O-Ring) inserts straight into the Interior Flow Connector Fitting.
Figure 26: Response Trigger Parts
A-5 Response Trigger Parts
(not shown in Parts Diagram)
02-103 Flow
Control
TA01026
Hose 1/8”
02-84
O-Ring
TA01060
Flow
Control
Adapter
TA10058 Interior
Flow Connector Fitting
20-02N RT Cylinder
02-82
Cylinder
Fitting
Gasket
TA10057
Cylinder Fitting
FA-07 Cylinder Fitting O-Ring
20-20 Banjo Fitting