![Timken Rollon Tecline Use And Maintenance Download Page 28](http://html1.mh-extra.com/html/timken/rollon-tecline/rollon-tecline_use-and-maintenance_1118193028.webp)
Use and Maintenance
UM-28
a.
Lock the plate (or the vertical profile) by placing it on its
lower mechanical stop with out removing pneumatic
pressure to the rod locking unit (Q).
b.
Remove the upper closing plate from profile (E) undoing the
4 countersunk head screws M10 (D) and loosen the
self-locking nut M20 (H), on the lower part of the module.
This nut is not tightened to torque and must remain loose
even after intervention to ensure the correct sliding of the
rod inside the rod locking safety system (Q).
c.
Remove plugs (A) using the correct removal tool.
d. Unscrew socket head cap screws M10 (C) taking care not
to completely unscrew them, so that mounting plugs M10
(F) do not fall in the slot.
e. Turn the side bar (G) as shown by the arrow in the figure,
accompanying the support rod (M) upwards, until it has
completely separated from the vertical profile.
f.
Undo hex head screws M14 (O) that secure bracket (P) of
the rod locking unit (Q) to the base plate and socket head
cap screws M12 (N1) which secure the bracket to the
upper part of the safety system.
Removal and replacement of the “rod locking” safety system (optional)
g.
Remove bracket
h.
Undo socket head cap screws M12 (N2) which secure
bracket (P) to the lower part of the safety system (Q).
i.
Without removing the pressure to the pneumatic system,
slide the locking system upwards (Q). Before removing it
completely insert a calibrated segment (R) of ø32 mm, to
prevent any damage to the internal locking system.
j.
Replace the recently removed rod locking unit with a new one.
k.
Perform the operation in reverse for refitting.