![Timken Rollon Tecline Use And Maintenance Download Page 27](http://html1.mh-extra.com/html/timken/rollon-tecline/rollon-tecline_use-and-maintenance_1118193027.webp)
Tecline
UM-27
Guide (C) has a housing in tolerance, so its adjustment is
much simpler. Simply put it in position and tighten
the screws, with the same procedure used for the guide (G).
Once all the screws have been tightened, perform a final
check before axis commissioning.
ATTENTION!
The recirculating ball guides should not be
lubricated (refer to section “Routine main-
tenance - Manual greasing and lubrication”.
g.
Guide adjustment
h.
Guide (G) does not have an housing in tolerance on the profile,
therefore it is necessary to use the carriage to ensure its
proper alignment. Slide the carriage along the recently
fitted guide: when the ball recirculation sliders have passed
above, leaving screws (A) accessible to the operator,
proceed with their tightening.