![Timken Rollon Tecline Use And Maintenance Download Page 22](http://html1.mh-extra.com/html/timken/rollon-tecline/rollon-tecline_use-and-maintenance_1118193022.webp)
Use and Maintenance
UM-22
6 Rollers oscillating slides ø52 mm and ø62 mm
Replacement:
Preloading setting:
a.
Unscrew the Ch24 self locking nut (A)
b.
Loosen the STEI M6 grain (B) upon the locking pivot (C)
c.
Unscrew (Ch10) and remove the locking pivot (C).
d.
Now the slide is loose and it is removable.
e.
Perform the operation in reverse for refitting, positioning
with care the two fifth-wheel with the teflon side in direct
contact with the slide replaced.
a.
Loosen the Ch17 nut (A) of eccentric pivots.
b.
Adjust the slide until all contact with the guide bearings,
turning the eccentric bushing (B) towards right or left.
c.
Screw the Ch17 nut (A).
To ensure the proper alignment and to minimize the clearance
during the translation, each axis is equipped with opposed
concentric and eccentric sliding bearings. Proceed as follows
to get the right preloading setting: