Troubleshooting
1. Upon fault of the dehumidifier, please cut off the power supply immediately, unplug the
plug and check the following items:
Faults
Cause Analysis
Eliminating Methods
Failure to operate
Shown as no
power
Power outage or unavailable
socket
Check if the power supply works well
If the plug is well plugged
Plug the power supply in the socket
Fuse of electric board is blown
out
Replace the fuse
Transformer of electric board
is broken
Replace the transformer
Shown as
power on
Environmental humidity lower
than the set value
Set again according to the demand
If the water tank is well placed
Place the water tank in right position
If the entire machine is
defrosting
Wait for completion of defrosting
Unfavorable
dehumidifying effect
If there’s obstacle at the air inlet/outlet
Remove the obstacle
If the door and window are open
Close the door and window
If the indoor temperature is too low
Don’t run the dehumidifier
Heavy noise
If the ground is firm and flat
Resettle the dehumidifier
Dehumidifier laid unsteadily
Steadily resettle the dehumidifier
Water leakage
Inclination
Adjust the dehumidifier to the flat position
Drain pipe/outlet obstructed
Dismantle the front plate to eliminate
impurities
E1
Fault of the coiler
Turn to timing for defrosting, and cancel
system fault function. It can be restored.
E2/E3
Fault of
humidity & temperature sensor
Replace the humidity & temperature sensor
EE
Refrigerant leakage
Start the machine after a certain while of
time. Ask for help from professionals if the
“EE” signal remains
8. If the said methods still fail to eliminate the troubles, please directly contact the manufacturer or
agents. Don’t disassemble the dehumidifier on your own.
9. It’s normal to hear the sound of the circulation of refrigerant when the dehumidifier runs.
10. It’s normal for the air outlet to reject heat.