defrosting mode
Description
Automatic Defrosting
Sensor at normal state
1. The compressor constantly run over 20 minutes,
coil temperature below 0 degree constantly over 30
minutes, it starts defrosting model.
2
、
Coil temperature over 5 degrees constantly over
90 seconds, or Defrosting time over 8 minutes, it
stopped defrosting mode.
Defrosting faults
Coil sensor faults
1. When ambient temperature over 25 degrees, it
will never start defrosting;
2. When ambient temperature below than 25
degrees but higher than 15 degrees, the compressor
runs constantly 30 minutes, it defrosts 10 minutes;
3. When ambient temperature below than 15
degrees and higher than 4 degrees, compressor runs
constantly 20 minutes, it defrosts 12 minutes;
Temp-damp sensor
faults
1. The compressor runs constantly over 20 minutes,
coil temperature below 0 degrees constantly run
over 20 minutes, it starts defrosting mode.
2. Coil temperature over 5 degrees constantly over
90 seconds; or defrosting time over 25 minutes, it
stops defrosting mode.
Coil sensor and
temp-damp sensor faults
1. The compressor run constantly over 40 minutes,
it defrosts 10 minutes;
4. Timing On/Off Function
When it’s powered on, you can set timer for powering off; and when it’s powered off, you can
set timer for powering on. Setting timer for both powering on and off then initiates the cycle timer
mode.
A. Set timer for powering on: When it’s powered off, press the “Timing” Button. As the
“Timing On” icon flickers and the time set flickers in relevant area, press “+” or “-” to adjust the