(Fig. 3)
3. Water tank usage: You may use the water tank in two ways. I) Direct use. When the water tank is
full, the machine automatically shuts down and enters the standby state, the LED displays the “Full
Water” signal and the hummer alarms. When the water tank is emptied and put in place again, the
dehumidifier can continue its performance. II) Continuous drainage. As shown in Fig. 3, to restore
the performance of the water tank, you need to take out the water tank, screw off the cover, drill
hole on the outlet, screw down the cover and mount the drain pipe.
*Tip: In continuous drainage, the drainage pipe shall not be set higher than the water tank.
Warning: If the power cord is damaged, it must be replaced by the professional person from
manufacturer, the maintenance department or similar departments.
Water Plug
Water Tank Cover
Drain Pipe
Water Tank
Water Tank Outlet
Summary of Contents for 102611934