17
Line 3 shows the next position of TigerCrossCut. This is where user
input is shown.
Line 4 displays the soft key prompts. These prompts tell you what the
soft key button below it does. These can change when you access
different screens.
Calibration Settings
Once homed, we will need to set a few settings to ensure TigerCrossCut is measuring properly.
Find the End Limits
1. From the Ready Screen, press the [Show] soft key to show the menu
options.
2. Press the [Menu] soft key to display the Menu Select screen.
3. TigerCrossCut requires a password to access all menu options.
Enter your TigerCrossCut password and press .
Note: By default, the TigerCrossCut password is set to the serial number.
4. At the Menu Select screen, press the [Setup] soft key to access the
Setup Menu.
5. Press
to scroll through the settings. Stop when you see FindLim.
6. Press
START
to run the Find End Limit routine.
Note: Ensure TigerCrossCut can move its entire length without obstruction.
TigerCrossCut will move once
START
is pressed.