MAINTENANCE AND OPERATION MANUAL
NOVA-65 SC/0111258-00
Tideland Signal
Page
17 of 32
0111258-00
Rev. B 16-Jun-16
Sequenced Flash
A group of Nova-65 SC lanterns can be configured to flash in sequence similar to
aircraft landing lights. This requires that each flasher have a GPS module installed.
Use SignalView to enable sequenced flash and to set each light’s individual delay.
Alternatively, to enable the sequenced flash feature, set switch S3-
4 to “ON”. The
address switch bank S4 now becomes the delay setting. Set S4 according to
Table 2 S4 Sequence Delay Table.
The first lantern in sequence does not need to be set for sequenced flash, but it is
recommended that it be set for sequential flash with a delay of 0 seconds. Each
subsequent light must be set for increasing delay depending on how far down in
sequence it will flash. The sequenced flash feature applies only to solitary lanterns
with GPS (as on a buoy), and must not be used in a system of interconnected
lanterns.