When operating in the Main/Standby configuration, units must be set to operate
in the Cutoff Mode (Lockout Mode disabled.)
Note
: Standby units respond faster to a “Main Fail” signal than to a
communication failure.
Standby Flash Character 58Hex
The standby unit can be programmed to flash Character 58Hex [FL(6) 15S]
when the Main unit fails.
Seasonal Operation
The MaxiHalo II controller can be programmed using SignalView to shut down
on a certain date and start up on another date. The optional Real Time Clock
(RTC) circuit, which maintains date and time information, is used by the main
controller to determine when to shut down and when to start up.
Alternate Code
When the “Alternate Code During Low-Voltage” feature is enabled the MaxiHalo
II controller, upon sensing a voltage below the Alternate Code Voltage threshold,
initiates an alternate flash code. When the voltage drops below the Low Voltage
Cutoff level, the MaxiHalo II controller disables the flasher and asserts a fail
condition. When the voltage rises to the Alternate Code Voltage threshold, the
MaxiHalo II controller is re-enabled and initiates with the primary flash code.
Threshold levels are set using SignalView (See
Figure 6 Cut Off Diagram).
Note: The MaxiHalo II controller can be commanded to override the Active
Code to flash the Alternate Code by selecting the “Enable Alternate Code”
command in SignalView.
Figure 6 Cut Off Diagram