Voltage balancing and monitoring
during the discharge
The processor monitors the voltage of individual cells
during “storage-mode” and “discharge” of Lithium battery
pack. It tries to normalize the voltages to be equal. For
this feature, the individual plug of the battery pack should
be connected to the individual port of the charger.
If the voltage of any one or more cells varies abnormally
during the procedure, it terminates the process forcibly
with the error message. If this happens, the battery
pack contains the bad cell, or the bad connection of the
cable or plug. You can easily know which one cell is
bad by pressing INC button at time of showing the error
message.
The processor found that
the voltage of one of the cell
in the Lithium battery pack
is too low.
In this case, the 4th cell is
bad. If there happens the
connection-break of the
cable or plug, the voltage
value may show zero.
NiMH/NiCd battery program
These programs are for charging or discharging NiMH
(Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium) battery
commonly used for
R/C
models applications. To alter
BATTERY VOL ERR
CELL LOW VOL
Display
INC
Display
4.14 4.16 4.09
2.18 0.00 0.00
Display
Display