Initial parameter set up (Users set up)
It will be operated with the default value of the essential
user settings when it is connected to a 12V battery or
a AC wall socket for the first time. The screen displays
the following information is sequence and the user can
change the value of parameter on each screen.
When you are willing to alter the parameter value in
the program, press
Start/Enter
key to make it blink
then change the value with
INC/DEC
key. The value
will be stored by pressing
Start/Enter
key once.
The screen displays the
nominal voltage of Lithium
battery. There are three
kinds of Lithium battery;
LiFe(3.3V), Lilo(3.6V) or
LiPo(3.7V). this is very
important so you have to
check the battery carefully
and set it up correctly. If it is different from correct value
the battery can explode during charge process.
I t r e c o g n i s e t h e c e l l
count of Lithium battery
a u t o m a t i c a l l y a t t h e
beginning of charge or
d i s c h a r g e p r o c e s s t o
a v o i d f r o m e r r o n e o u s
setting by user. But deeply
discharged battery can be
LiFe
V.Type
3.3V
Display
- +
DEC INC
DEC INC
LiPo/Lilo/LiFe
CHK Time 10min
Display
Display
- +
DEC INC
DEC INC