TT-3000E mini-C GMDSS System
Installation Manual
4.8
TT-3042C
R
EMOTE
A
LARM
/D
ISTRESS
B
OX
Figure 49 TT-3042C Remote Alarm/Distress Box
From the Remote Alarm/Distress Box TT-3042C Distress Alerts
can be initiated. The TT-3042C also has an indicator for
reception of EGC messages with distress/urgent priority. A
Distress Alert can be initiated by pressing the Distress button
for five seconds.
Included in the box is a Distress Relay, which makes it
possible to control an external alarm panel. The function of
the relay can be selected by setting two internal jumpers
according to the specifications in Table 18 TT-3042C
Technical Specifications. In case jumper W1 is set to enable
the Distress Relay, it will be activated upon reception of a
SafetyNet Message with distress priority.
The light intensity of the green power indicator can be
adjusted by a knob below it.