TT-3000E mini-C GMDSS System
Installation Manual
Figure 47 RS232 Adapter Cable for Service Interface
The terminal settings are 38400, N, 8, 1. If connected using
Windows HyperTerminal® or equivalent, the following will be
seen during power up:
Thrane & Thrane (c), Alarm panel, AP5042
Reset by power-up
Panel node ID : 3
:
To get a list of available commands, type “help<cr>”.
4.7.4
AP5042
I
NITIAL CHECK AND CONFIGURATION
Pressing and holding the Test button will make all light
indicators and the alarm button flash. Pressing any other
button while holding the Test button, will sound the buzzer
enabling verification of the buttons and the audible indicator.