TT-3000E mini-C GMDSS System 

Installation Manual 

 

4.3

 

TT-3026C

 MINI

-C

 

T

RANSCEIVER 

I

NSTALLATION

 

The TT-3026C mini-C Transceiver is equipped with an 18-pin 
female connector and is meant for flat surface mounting or 
pole mounting using an optional adaptor. 
 

4.3.1

 

M

OUNTING OPTIONS

 

This section describes the different mounting options 
applicable for the TT-3026C mini-C transceiver. 
 

4.3.1.1

 

D

RILLED HOLES ON A FLAT SURFACE

 

1)

 

Drill the 4 holes (3 for the mounting screws, 1 for 
cable access) using the mounting stencil in Appendix 
A. 

2)

 

Place the friction gasket on the surface. 

3)

 

Connect the cable and mount the screws. 

 

4.3.1.2

 

P

OLE MOUNT 

1” 

40-3026 Opt. 101 is a standard 1” pole mount, Illustrated in 
Figure 11. 
 

1)

 

Pull the cable in the pole and adapter. 

2)

 

Connect the cable to the transceiver. 

3)

 

Mount the adapter on the transceiver using screws. 

4)

 

Tighten the adapter to the pole. Adjustable between 
20 - 35 millimetre  

 
NOTE: THE POLE MOUNT DEVICE HAS TO BE DISMOUNTED 
FROM THE TRANSCEIVER BEFORE THE CABLE IS CONNECTED 
OR DISCONNECTED

 

33/97 

Summary of Contents for SAILOR TT-3000E mini-C GMDSS System

Page 1: ...em Installation Manual Copyright Thrane Thrane A S ALL RIGHTS RESERVED 2006 Thrane Thrane A S Information in this document is subject to change without notice and does not represent a commitment on the part of Thrane Thrane A S Document number 98 122414 Revision B Release Date 18th of July 2007 1 97 ...

Page 2: ...TT 3000E mini C GMDSS System Installation Manual This page is intentionally left blank 2 97 ...

Page 3: ...rements MICROWAVE RADIATION HAZARDS During transmission this unit radiates microwaves from the antenna This radiation may be hazardous if exposed directly to humans close to the antenna Make sure that nobody is closer than the recommended minimum safety distance of 1 ft 0 3 meters during use of the transceiver KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove equipment covers Only q...

Page 4: ...TT 3000E mini C GMDSS System Installation Manual This page is intentionally left blank 4 97 ...

Page 5: ...Power Supply 23 2 9 TT 3606E Opt 003 NMEA Adapter 24 2 10 Accessories 25 3 Registration 26 4 System Installation 29 4 1 Power requirements 30 4 1 1 Fuses 30 4 2 Compass Safe Distance 32 4 3 TT 3026C mini C Transceiver Installation 33 4 3 1 Mounting options 33 4 3 1 1 Drilled holes on a flat surface 33 4 3 1 2 Pole mount 1 33 4 3 1 3 Adjustable Pole Railing Mount 34 4 3 2 Antenna Mounting Condition...

Page 6: ...port 59 4 5 1 3 Printer port 59 4 5 2 TT 3601E keyboard 59 4 5 3 Mounting 60 4 6 TT 3608A Hard Copy Printer 62 4 6 1 Mounting plate 63 4 6 2 Roll Paper Stand 63 4 6 3 Mounting 64 4 7 AP5042 Inmarsat C Alarm Panel 65 4 7 1 Mounting 65 4 7 1 1 Bracket Mount 66 4 7 1 2 Flush mount 68 4 7 2 Grounding 70 4 7 3 Connecting AP5042 70 4 7 3 1 AP5042 Power Connection 71 4 7 3 2 AP5042 Network Address Config...

Page 7: ...x 82 5 2 3 AP5042 Inmarsat C Alarm Panel 82 5 3 Link test 83 5 4 Test of backup supply 83 6 Maintenance guidelines 85 6 1 Handling Precautions 85 7 Appendix A 86 7 1 Mounting stencil 86 8 Appendix B 87 8 1 TT 3026C Cable Information 87 9 Appendix C 88 9 1 TT 3026C Specifications 89 9 2 TT 3606E Specifications 91 9 3 TT 3042C Specifications 92 9 4 TT 3616C Specifications 93 9 5 AP5042 Specification...

Page 8: ...emplate All measures in mm 42 Figure 19 Grounding using 4mm2 wire 43 Figure 21 Power cable connections 45 Figure 22 Transceiver cable preparation 46 Figure 23 Preparation for grounding of the cable screen 47 Figure 24 Fixation of the transceiver cable in TT 3616C 48 Figure 25 Mounting of transceiver cable wires 49 Figure 26 RS232 cable connection 50 Figure 28 Preparation of cable for alarm panels ...

Page 9: ...bly 69 Figure 48 RS232 Adapter Cable for Service Interface 73 Figure 49 System detected unit ready 74 Figure 50 TT 3042C Remote Alarm Distress Box 75 Figure 51 TT 3042C Mounting stencil 76 Figure 52 TT 3042C connector label 77 Figure 53 TT 3616C LED s and fuses locations 78 Figure 54 Mounting stencil 86 Figure 55 DeviceNet cable cross section Thick 96 Figure 56 Rockwell DeviceNet T Connector 96 Fi...

Page 10: ... 52 Table 10 TT 3606E Power Connector 58 Table 11 TT 3606E Std power cable coding 58 Table 12 Pinout of Inm C connector on AP5042 70 Table 13 Pinout of Power connector on AP5042 71 Table 14 Node ID adressing 72 Table 15 TT 3026C cable pin assignment 87 Table 16 TT 3026C Technical Spectifications 90 Table 17 TT 3606E Message Terminal Specifications 91 Table 18 TT 3042C Technical Specifications 92 T...

Page 11: ...ny portion of the outer cover Read the safety summary at the front of this manual before installing or operating the TT 3000E mini C GMDSS System Contents of the shipment should be as listed in the enclosed packing list If the contents are incomplete if there is mechanical damage or defect or if the system components do not work properly notify your dealer After you unpack the system please Inspec...

Page 12: ...ot available the following general instructions should be used for repackaging with commercially available material Wrap the equipment in heavy paper or plastic Attach a tag indicating the type of service required return address model number and full serial number Use a strong shipping container e g a double walled carton made of 160 kg test material Seal the shipping container FRAGILE to ensure c...

Page 13: ...rovider LED Light Emitting Diode LES Inmarsat C Land Earth Station LESO Inmarsat C Land Earth Station Operator LNA Low Noise Amplifier radio receiver MES Mobile Earth Station NCS Inmarsat C Network Coordination Station NMEA National Marine Electronics Association Opt Short for option PSA Point of Service Activation PVT Performance Verification Test SARF Service Activation Registration Form SCADA S...

Page 14: ...system is shown in Figure 1 The individual products are briefly introduced in this section For detailed information about installation please refer to the following sections Figure 1 TT 3000E mini C GMDSS System overview A general introduction to the Inmarsat C network is given in the User Manual 1 14 97 ...

Page 15: ...gned to operate in a corrosive environment and in extreme weather conditions without any service The TT 3026C mini C Transceiver is designed to operate when the satellite is visible over the horizon and no signal path blockage is present The TT 3026C mini C Transceiver antenna has an elevation angle of 15 ensuring perfect reception in sea area A3 Inmarsat even when the vessel has pitch and roll mo...

Page 16: ...026C mini C Transceiver and up to 20 meters away from the TT 3606E Message Terminal Figure 3 TT 3616C GMDSS Interconnection Box 2 3 AP5042 INMARSAT C ALARM PANEL A mandatory part of a TT 3000E mini C GMDSS System is the installation of a distress alarm panel The AP5042 Inmarsat C Alarm Panel is intended specifically for this purpose AP5042 can be used as a supplement or replacement for TT 3042C Re...

Page 17: ...5042 Inmarsat C Alarm Panels can be connected to a TT 3000E mini C GMDSS System 2 4 TT 3042C REMOTE ALARM DISTRESS BOX A mandatory part of a TT 3000E mini C GMDSS System is the installation of a distress alarm panel The TT 3042C Remote Alarm Distress Box is designed specifically for this purpose 17 97 ...

Page 18: ...42C Remote Alarm Distress Box Up to three TT 3042C Remote Alarm Distress Boxes can be connected to a TT 3000E GMDSS System The TT 3042C comes in a special modular version for bridge systems It has the exact same functionality but a different mechanical design 18 97 ...

Page 19: ...terface towards different Thrane Thrane GMDSS installations is needed It can interface towards two Inmarsat C GMDSS Systems two VHF GMDSS Systems and one MF HF GMDSS system Figure 6 AP4365 Alarm Panel AP5065 Alarm Panel is designed to be installed at the cunning position For ships with more than one position from where 19 97 ...

Page 20: ...an interface towards 3rd party monitoring systems The relevant alarm statuses for all attached GMDSS systems are constantly transmitted on a RS422 line On another RS422 line it is possible for 3rd party equipment to issue a mute command in order to silence all GMDSS systems For installation of AP5065 please refer to the installation manual delivered with the unit 20 97 ...

Page 21: ...6E MESSAGE TERMINAL The TT 3606E is a GMDSS approved Message Terminal for the TT 3000E mini C GMDSS System It provides means to send and receive messages monitor system status change the configuration and test the system Figure 7 TT 3606E Message Terminal 21 97 ...

Page 22: ...anual 2 7 TT 3608A HARD COPY PRINTER Figure 8 TT 3608A Hard Copy Printer The physical installation of the printer is covered by this manual section 4 6 Usage and maintenance of the printer is covered by the manual provided with the printer 22 97 ...

Page 23: ...ply in case of mains dropout Figure 9 N163S Power Supply Use of the N163S is optional but it is a requirement of IMO that the GMDSS installation is made such that it is operational both from the ships main source of energy and from an alternative source of energy Please refer to the installation manual delivered with N163S for further installation information 23 97 ...

Page 24: ...S receiver in the TT 3026C mini C Transceiver is needed by external equipment like VHF radios etc the TT 3606E Opt 003 NMEA Adapter is needed to translate the information into proper NMEA signal levels Please refer to the installation manual delivered with the TT 3606E Opt 003 NMEA Adapter for further installation information TT 98 124401 24 97 ...

Page 25: ...Picture Opt 101 Standard 1 pole mount kit Opt 103 Adjustable pole railing mount kit Opt 940 Connection cable 5 meters with 90 angular plug Opt 941 Connection cable 5 meters Opt 942 Connection cable 10 meters Opt 943 Connection cable 20 meters Opt 946 Connection cable 50 meters Table 1 Accessories 25 97 ...

Page 26: ...ompany handling the activation of Inmarsat mobiles and is short for Point of Service Activation ISP is the company that provides the Inmarsat service and is short for Inmarsat Service Provider In many cases the PSA and ISP is the same company that also operates a Land Earth Station LES The local PSA or ISP can be obtained by following the guidelines in the registration form The Service Activation ...

Page 27: ...TT 3000E mini C GMDSS System Installation Manual Figure 10 Page 1 of the Service Activation Registration Form 27 97 ...

Page 28: ...ior to operating the mini C MES it must be configured with this Mobile Number The mobile number can be entered using the TT 3606E Message Terminal 1 Choose Options Configuration Terminal mode Alt O C T and wait for the blinking cursor to appear This may take a while if the transceiver and the Message Handling program are communicating 2 Press Enter to see the prompt on the screen 3 Type se u xxxxx...

Page 29: ...08A Hard Copy Printer TT 3042C Remote Alarm Distress Box AP5042 Inmarsat C Alarm Panel Please note that installation of N163S Power Supply and AP5065 Alarm Panel are covered by separate manuals provided with the units IMPORTANT DO NEVER TEST THIS INSTLLATION BY SENDING AN ALERT ON AIR ALSO BE CAREFUL NOT TO SEND FALSE ALERTS DURING INSTALLATION Any distress alerts coming through the Inmarsat C net...

Page 30: ...GMDSS Interconnection Box Floating DC 10 5 32V 1W 2W TT 3606E Message Terminal incl Keyboard Floating DC 10 5 32V 13W average 20W peak TT 3608A Printer 220AC or option 010 DC supply floating 10 5 32V 33W 33W AP5042 8 32V 0 3W 0 8W AP5065 21 32V 1W 3W TT 3042C Remote Alarm Distress Box 0 2 W standby 1W Total 50W 92W Table 3 System component power requirements 4 1 1 FUSES In case you experience that...

Page 31: ... able poly fuse NA TT 3616C GMDSS Interconnection Box Internally accessed remove top cover 5 A ATO type As used in cars TT 3608A Hard Copy Printer Internally accessed remove top cover 1 5A mT N163S Power Supply Mains supply Externally accessed 1 A mT 230VAC 2 A mT 110VAC N163S Power Supply Battery input Internally accessed remove top cover 10 A ATO type As used in cars Table 4 TT 3000E mini C GMDS...

Page 32: ...safe distances found are Model Compass Safe Distance TT 3026C Transceiver 0 3 m TT 3616C Interconnection Box 0 8 m TT 3606E Message Terminal 1 0 m TT 3601E Keyboard 0 2 m TT 3601A Keyboard 0 5 m TT 3042C Remote Alarm Distress Box 0 2 m TT 3608A Hard copy printer 1 3 m N163S Power supply 1 0 m AP4365 Alarm Panel 0 9 m AP5042 Inmarsat C Alarm Panel 0 4 m AP5065 Alarm Panel 0 4 m TT 3606E Opt 003 NME...

Page 33: ...SURFACE 1 Drill the 4 holes 3 for the mounting screws 1 for cable access using the mounting stencil in Appendix A 2 Place the friction gasket on the surface 3 Connect the cable and mount the screws 4 3 1 2 POLE MOUNT 1 40 3026 Opt 101 is a standard 1 pole mount Illustrated in Figure 11 1 Pull the cable in the pole and adapter 2 Connect the cable to the transceiver 3 Mount the adapter on the transc...

Page 34: ...s it is recommended that the Adjustable Pole Railing Mount described below is used 4 3 1 3 ADJUSTABLE POLE RAILING MOUNT 403026 Opt 103 is an adjustable pole railing mount shown in Figure 12 1 Attach the pole mount to the transceiver using the 3 screws 2 Mount the device to the pole in one of the 2 directions 3 Connect the cable Figure 12 Vertical and Horizontal adjustable pole mount 34 97 ...

Page 35: ...ransceiver Important Remember to check the corresponding requirement of the other equipment 0 5 meter Distance to magnetic compass 0 3 meter Table 6 Antenna Safe Distance The antenna is designed to provide satellite coverage even when the vessel has pitch and roll movements up to 15 To maintain this coverage the antenna should be free from obstructions in the area down to 15 below the horizon see ...

Page 36: ...itioned in such a location that the obstruction covers no more than a 2 arc along the horizon To calculate the minimum distance use the following formula Safe distance 29 Diameter of obstruction Example Obstruction is a 4 pole Diameter 0 1 m Safe distance is 29 0 1 m 2 9 m 2 9m apart to ensure that obstruction covers no greater than 2 arc TT 3026C mini C Transceiver 4 diameter obstruction Figure 1...

Page 37: ...026C must be connected to the TT 3616C GMDSS Interconnection Box by use of a special cable delivered with the system There are 4 lengths of connecting cables available from T T 5m 10m 20m and 50m refer to section 2 10 for option numbers Refer to Appendix B to get information about the individual signals found in the cable 4 3 5 GROUNDING Make sure that the shield of the cable is connected to a pro...

Page 38: ...V to accommodate power supply variations outside the nominal range Note In case a 50 meter transceiver cable is used Opt 946 the minimum supply voltage measured at the TT 3616C terminals must be 16VDC 4 3 8 GENERAL PURPOSE I O PORTS The TT 3026C mini C Transceiver also contain two configurable input output ports available to the user via the TT 3616C GMDSS Interconnection Box They are named I O 5 ...

Page 39: ...e input voltage must be 3V Voltage allowed between GND and the input pin is 0V to 5V WARNING When using the I O ports it is important not to apply voltages between GND and the I O pin higher than 5 VDC as this can cause damage to the transceiver Negative voltages are not allowed either 39 97 ...

Page 40: ...l 4 4 TT 3616C GMDSS INTERCONNECTION BOX The TT 3616C GMDSS Interconnection Box is designed to facilitate a simple and robust interconnection of the various system components Figure 15 Outside view of TT 3616C Figure 16 Inside view of TT 3616C 40 97 ...

Page 41: ...at surface anywhere inside a vessel and to be located up to 50 meters away from the TT 3026C mini C Transceiver and up to 20 meters away from the TT 3606E Message Terminal In order to ease the installation please observe the minimum clearing area as given in Figure 17 Figure 17 Recommended free space around TT 3616C 41 97 ...

Page 42: ...The best grounding is made by screwing the chassis directly on to the ships structure provided it s made of metal If proper grounding can not be made this way then connect the pre mounted grounding wire to the ships structure Find an appropriate location as close as possible to the TT 3616C and shorten the grounding wire accordingly Terminate the grounding wire with the yellow ring terminal found ...

Page 43: ...ire Please note the use of a washer as shown in Figure 19 The grounding wire delivered with the TT 3616C has a length of 1 meter and a wire cross section of 4mm2 Avoid extending the length of the grounding wire as the protective effect will be severely degraded in such a case 43 97 ...

Page 44: ...s well 4 4 3 CONNECTING POWER TO TT 3616C The power connector is designed to accept wire with a cross section area up to 2 5mm2 The required wire cross section depends on the actual supply voltage the supply cable length and the transceiver cable length Typical cable resistance is given in Table 8 Cross section mm2 0 5 1 1 5 2 2 5 Resistance Ω km 32 2 16 1 10 7 8 05 6 76 Table 8 Typical cable resi...

Page 45: ...length is LMAX 50M 58 m Example 2 Using a 12V battery for backup VMIN can be assumed to be above 11V if properly charged Using 20 meter of transceiver cable and a wire cross section of 2 5mm2 the maximum power supply cable length is LMAX 20M 11 m When connecting the cable to TT 3616C make sure the cable screen is properly terminated at the cable relief bracket as shown in Figure 21 Connect the pos...

Page 46: ... connection to DC via a switch then all equipment except the printer can be switch on and off by a simple low power switch 4 4 4 CONNECTING TT 3026C TO TT 3616C In order to prepare the transceiver cable for mounting start by removing 20 cm of isolation as shown in Figure 22 Figure 22 Transceiver cable preparation Then wind the tinned wire around the isolation as shown in Figure 23 in order to prep...

Page 47: ... 3000E mini C GMDSS System Installation Manual Figure 23 Preparation for grounding of the cable screen Then fasten the cable firmly in the cable relief bracket of the TT 3616C as shown in Figure 24 47 97 ...

Page 48: ... in TT 3616C Finally connect the individual wires to the 18 pole terminal block It is labelled by wire colour Connect the Transceiver cable as directed by these labels Start by connection the thick power wires and then continue towards the other end of the connector as shown in Figure 25 48 97 ...

Page 49: ...TT 3000E mini C GMDSS System Installation Manual Figure 25 Mounting of transceiver cable wires 49 97 ...

Page 50: ...as shown in Figure 26 Figure 26 RS232 cable connection Be aware that it might be easier to tighten the screw locks on the RS232 cable if it s mounted before the adjoining cables are mounted In order not to stress the connector the cable release bracket shown in Figure 26 must be used An extended serial communication cable must not exceed 20 meters 50 97 ...

Page 51: ...2 Figure 27 Alarm panel connectors In order to prepare the cable for mounting start by removing 12 cm of isolation as shown in Figure 22 remove 14 cm of isolation if connecting to J902 Figure 28 Preparation of cable for alarm panels Make sure the cable screen is proper folded around the cable isolation before mounting Start by fastening the cable firmly in the cable relief bracket of the TT 3616C ...

Page 52: ...istress Box ref section 4 7 Label Wire colour code 9V DC GND I O 0 I O 1 I O 2 I O 3 I4 I5 Table 9 Actual wire colour codes 4 4 7 CONNECTING AP50XX TO TT 3616C Up to four AP5042 and one AP50652 can be connected directly to the TT 3616C3 via the RS485 interface accessible on connector J302 2 More AP5065 can be connected in parallel refer to the AP5065 Installation Manual for more information 3 The ...

Page 53: ...ation to termination should not exceed 500 meters and the length from TT 3616C to either end of the cable should not exceed 250 meter The cable screen should only be connected at the TT 3616C Please note that J302 only accepts wires with a cross section of up to 0 5mm2 4 4 7 1 T PORT WIRING The individual units can be connected to the string using short stubs with a maximum length of 5m as shown i...

Page 54: ...r provided the cable is not too thick 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 Data Data 9V GND 9 8 7 6 5 4 3 2 1 Data Data 9V GND Male DSUB9 Male DSUB9 Male DSUB9 TT 3616C 9 8 7 6 5 4 3 2 1 Male DSUB9 Connect to AP50xx 9 8 7 6 5 4 3 2 1 Data Data 9V GND Male DSUB9 GND Data Data 9V J302 Strap activates internal termination resistor Shield Shield Connect to AP50xx Connect to AP50xx Connect to AP50xx Con...

Page 55: ...If the cable is terminated in TT 3616C please mount a 120Ω 1 4W resistor between Data and Data in order to ensure a proper termination of the signal 4 4 7 3 DIRECT WIRING AP5042 POWERED FROM TT 3616C In case one of the AP5042 s are located less than 50 meters from the interconnection box a setup as shown in Figure 33 can be used in order to save an extra power supply unit Figure 33 Powering AP5042...

Page 56: ...provided It is connected to TT 3616C using a wire length of less than 5 meters The wire is NOT terminated at the AP5042 No TT 3042C is connected at J903 and 9V and GND for the extra alarm panel is taken from J903 It might be necessary to join the three Data signals as well as the three Data signals externally within centimeters from J302 as the resulting wire cross section might be too thick for J...

Page 57: ...the TT 3000E mini C GMDSS System Figure 34 TT 3606E Message Terminal In the following sections the interface to the 3606E Message Terminal is described Please be advised that a special Reference Manual for the TT 3606E Message Terminal is available 4 4 5 1 CONNECTORS An illustration of the rear connectors are shown in Figure 35 57 97 ...

Page 58: ...upply DC Return Battery Negative input 6 Remote ON OFF ON if connected to supply OFF if floating 7 8 SGND Chassis Secondary GND 3 11 14 15 NC Table 10 TT 3606E Power Connector The standard cable delivered with the TT 3606E Message Terminal has a 15 pin SubD female connector already mounted The wire color codes are as given in Table 11 Color Name Signal Description Red supply 10 32 VDC Battery Posi...

Page 59: ...ls are used as default The pin assignment for the two communication ports are identical 4 5 1 3 PRINTER PORT The TT 3606E Message Terminal has a standard Centronics printer port The printer port connector is located on the rear panel 4 5 2 TT 3601E KEYBOARD The TT 3601E Keyboard plugs into the Keyboard connector on the rear panel of the TT 3606E The keyboard connector is a standard connector but p...

Page 60: ...gure 36 illustrates the dimension of the panel cut out and position of mounting holes when mounting the TT 3606E Message Terminal in a console Figure 36 Mounting holes for TT 3606E Figure 37 illustrates the position of the mounting holes for the mounting bracket 60 97 ...

Page 61: ...TT 3000E mini C GMDSS System Installation Manual Figure 37 TT 3606E Mounting Bracket 61 97 ...

Page 62: ... for floppy disk storage In case TT 3608A and TT 3606E are turned off the Transceiver will hold the incoming messages in the internal memory for at approximately 48 hours for later Hard Coping The enclosed standard cable allows the printer to be located up to 1 5 meters from the Transceiver A special low impedance cable is available for printer locations up to 20 meters from the Message Terminal T...

Page 63: ...es to work and Printer almost out of paper message is displayed by the message terminal When a Printer almost out of paper condition occur the audio alarm will sound and the fault indication on any connected alarm panel will be switched on these indications continues until the paper roll is replaced If the printer is set off line using the select button or powered off using the power switch the au...

Page 64: ...m Installation Manual before the advanced paper low option is enabled The DIP switch can be accessed by removing the switch cover from the back of the printer 4 6 3 MOUNTING Figure 40 Mounting holes for TT 3608A Unit is mm 64 97 ...

Page 65: ...el From the AP5042 Inmarsat C Alarm Panel distress alerts can be initiated A distress alert can be initiated by pressing the Distress button for five seconds The AP5042 also has an indicator for reception of EGC messages with distress or urgent priority 4 7 1 MOUNTING Two mounting options exist Bracket Flush mount 65 97 ...

Page 66: ...on Manual 4 7 1 1 BRACKET MOUNT The outline and dimensions for a bracket mounted AP5042 are shown in Figure 42 100 128 min 150 60 5 31 5 Space for cable entry All dimensions are in millimetres Figure 42 Outline dimensions bracket mount 66 97 ...

Page 67: ...TT 3000E mini C GMDSS System Installation Manual The drilling template for the bracket is shown in Figure 43 Figure 43 Drilling template bracket 67 97 ...

Page 68: ...or a flush mounted AP5042 are shown in Figure 44 Panel Mounting Bracket Space for cable entry min 150 9 6 140 All dimensions are in millimetres Figure 44 Outline and dimensions flush mount The drilling template is shown in Figure 45 and the 3 dimensional assembly drawing is shown in Figure 46 68 97 ...

Page 69: ...TT 3000E mini C GMDSS System Installation Manual Figure 45 Drilling template flush mount Figure 46 Flush mount assembly 69 97 ...

Page 70: ...ower The connector marked Inm C is used for communication with the TT 3000E mini C GMDSS System The pin out is shown in Table 12 For further information concerning wiring of the communication interface please refer to section 4 4 7 Female DSUB 9 pin connector marked Inm C Pin Signal Remark 1 GND Internally connected to pin 2 2 GND Internally connected to pin 1 3 Data Internally connected to pin 7 ...

Page 71: ... 1 selection 2 S RX RS232 Service i f RX input 3 S TX RS232 Service i f TX output 4 Node ID 1 Bus address selection pin 5 S GND RS232 Service i f GND 6 DC 7 DC Nominal voltage 24V DC Can operate from 8V to 32V DC 8 Node ID 0 GND GND for Node ID 0 selection 9 Node ID 0 Bus address selection pin Table 13 Pinout of Power connector on AP5042 4 7 3 1 AP5042 POWER CONNECTION Connect 24VDC between Power ...

Page 72: ...nt AP5042 s need to get the address pins strapped according to Table 14 ID Node ID 1 Node ID 0 3 1st AP5042 Floating Floating 2 2nd AP5042 Floating Strap to Node ID 0 GND 1 3rd AP5042 Strap to Node ID 1 GND Floating 0 4th AP5042 Strap to Node ID 1 GND Strap to Node ID 0 GND Table 14 Node ID adressing 4 7 3 3 AP5042 SERVICE INTERFACE Normally there is no need to access the RS232 service interface b...

Page 73: ... during power up Thrane Thrane c Alarm panel AP5042 Reset by power up Panel node ID 3 To get a list of available commands type help cr 4 7 4 AP5042 INITIAL CHECK AND CONFIGURATION Pressing and holding the Test button will make all light indicators and the alarm button flash Pressing any other button while holding the Test button will sound the buzzer enabling verification of the buttons and the au...

Page 74: ... in Figure 48 Figure 48 System detected unit ready In case there are two Inmarsat C GMDSS Systems on the vessel it is possible to toggle between the indication text Inm C 1 and Inm C 2 by 1 Press and hold the Test button 2 Press and hold the Mute button 3 Wait with both buttons pressed and the buzzer active until the text change 4 Release both buttons 74 97 ...

Page 75: ...itiated by pressing the Distress button for five seconds Included in the box is a Distress Relay which makes it possible to control an external alarm panel The function of the relay can be selected by setting two internal jumpers according to the specifications in Table 18 TT 3042C Technical Specifications In case jumper W1 is set to enable the Distress Relay it will be activated upon reception of...

Page 76: ...or w all mounting 4 A lternativ cable hole C onsole mounting hole 27 80 18 9 5 B A A A 6 B A B 6 B Figure 50 TT 3042C Mounting stencil Fasten the TT 3042C Remote Alarm Distress Box from the inside or by using the mounting bracket which makes console mounting possible If required the cable relief are easily moved from the end of the TT 3042C to the bottom feed hole for hidden cable installation 76 ...

Page 77: ... and control signals The cable used has to be in compliance with the specifications in Table 18 TT 3042C Technical Specifications Connect each wire as indicated by the label and in accordance with the wire colour codes chosen refer to 4 4 6 Connecting TT 3042C to TT 3616C Figure 51 TT 3042C connector label Do not connect the cable screen and make sure it does not short circuit anything 77 97 ...

Page 78: ...ase refer to the user manual ref 1 5 1 BASIC SYSTEM VERIFICATION The TT 3616C Interconnection Box has 6 light emitting diodes LED s to provide basic installation and troubleshooting help The location of the LED s is shown in Figure 52 Spare fuse 5 Amp fuse Figure 52 TT 3616C LED s and fuses locations 5 1 1 DC IN LED When applying power to the TT 3616C the DC in LED will light up provided the fuse ...

Page 79: ...connected to DC if not then the system is supposed to be turned off 3 Check the mini C Transceiver cabling 4 Check that the supply voltage measured on J602 between DC and DC is above 10 5 VDC 5 Toggle remote on off by leaving it floating for 1 second before reconnecting it to DC 5 1 3 3616C OK LED For normal operation the 3616C OK LED should be steady on when the system is powered A flashing 3616C...

Page 80: ... flashing If the SSAS option is correctly installed the LED will be steadily lit Refer to ref 3 for further information 5 1 6 GMDSS OK LED This LED is controlled by software and can only be trusted provided the 3616C OK LED is steadily lit When one or more distress alarm panels are installed the GMDSS OK LED should be steadily lit In case the GMDSS OK LED is flashing then 1 Check that the alarm pa...

Page 81: ...the Message Terminal asks the operator if distress test mode should be cancelled Do not answer yes to this question unless you are absolutely sure that you have completed distress testing In Distress Test Mode the Distress Buttons can be activated and tested without issuing Distress Alerts Distress Test Mode is cancelled by pressing the Esc key After Distress Test Mode is terminated activating the...

Page 82: ...st mode is initiated the text Test will be shown in green letters on the display line A cyclic test sequence will 1 Switch on the Distress text 5 seconds 2 Sound the buzzer 5 seconds 3 Switch off the buzzer and the Distress text and switch on the Fault text 5 seconds 4 Switch off the Fault text All other segments on the display line will be lit constantly during the test Test of the Distress Butto...

Page 83: ...ed Click Activate to start the test After a while the window will be updated with the text Automatic test mode Normal communication disabled Do not press any distress buttons unless you are in distress The printer will print a message saying Link Test request issued then a Link Test request successful and a Link Test started When receiving the results the screen will display Link Test finished and...

Page 84: ...em Installation Manual When using the N163S Power Supply simply switch of the mains supply on the switch found on the front of the unit Observe that the system continues to work uninterrupted from the 24V DC backup battery 84 97 ...

Page 85: ...t for service 6 1 HANDLING PRECAUTIONS Do not expose the transceiver s parting line the blue styling gasket connector to high pressure water jets Exposure of chemical containing alkalis may result in physical degradation of the transceiver Do not expose the transceiver to acid curing silicone Avoid contact with solvents Do not paint the transceiver If it is absolutely necessary to paint the transc...

Page 86: ... mini C GMDSS System Installation Manual 7 APPENDIX A 7 1 MOUNTING STENCIL Figure 53 Mounting stencil For connector predrilled hole 32mm 1 26 diameter A 3 x predrilled holes 5mm 0 2 diameter for M4 screws 86 97 ...

Page 87: ... Remote ON OFF White GND GND Orange GND GND Black Violet 3V3 out 3V3 out max 100mA for terminal equipment Black Blue Grey Black Yellow Black Grey Brown Black Green I O port 1 2 3 4 5 6 1 to 4 reserved 5 to 6 user configurable 3 3V I Os 5V tolerant Each open collector output sinks 25mA Green RD RS232 Receive Black Red TD RS232 Transmit Violet RTS RS232 Request to send Blue CTS RS232 Clear to send T...

Page 88: ...TT 3000E mini C GMDSS System Installation Manual 9 APPENDIX C Appendix C holds technical specification for the following units TT 3026C TT 3606E TT 3042C TT 3616C AP5042 88 97 ...

Page 89: ...me Length 8 64 seconds TX Signalling Access Mode Slotted ALOHA TX Message Channel TDMA FDMA interleaved code symbols Terminal Interface EIA TIA 232 E DTE interface CCITT Rec V 24 28 4800 115200 Baud IA 5 code I O Interface Six dedicated In Out pins Open collector Sinks 25 mA each System Set up S RAM Battery backup DC Power Source Floating DC Nominal voltage range is 12V to 24V Working voltage rang...

Page 90: ...Codes DNID Messaging Program Unreserved Data reporting Transmit message size Max 10Kbyte Receive storage 32 Kbytes TT 3026C mini C Transceiver Inmarsat C GPS omnidirectional antenna RHC polarised G T 23 7 dB K at 5 elevation EIRP 7 dBW dB at 5 elevation Temperature 35 C to 55 C operating 40 C to 80 C storage Maximum transmission length 10 Kbytes Solar Radiation Max flux density 1200W m2 Precipitat...

Page 91: ...r SOLAS with distress call functions CN114 and IEC 60945 requirements Meets CE marking 1997 requirements Wheel Mark approved Power Source 10 5 to 32 V floating DC 15 pin SubD female Power Consumption App 20 Watts maximum App 13 Watts typical Fuse Internal automatic recovering poly fuse Ambient Temperature 20 C to 55 C operating 40 C to 80 C storage Compass safe distance 50 cm measured in accordanc...

Page 92: ... MES Fault Relay Max switching 2A or 60W or 220V AC Distress Relay jumpers Enable W1 1 2 Disable W1 2 3 Activated Shorted W2 1 2 Open W2 2 3 MES Fault Relay jumpers Enable W3 1 2 Disable W3 2 3 Activated Open W4 1 2 Shorted W4 2 3 Temperature 25 C to 55 C operating 40 C to 80 C storage Relative humidity 95 non condensing at 40 C Vibration operational Random vibrations 5 20 Hz 0 005 g Hz 20 150 Hz ...

Page 93: ...ributed to alarm panels excluding power distributed to TT 3026C Connector 2 x DSUB9 Female 67 x Spring type terminals max 2 5mm2 Fuse 5 A ATO type spare fuse included Temperature 25 C to 55 C operating 40 C to 80 C storage Relative humidity 95 non condensing at 40 C Vibration operational Random vibrations 5 20 Hz 0 005 g Hz 20 150 Hz 3 dB oct 0 5 g rms Sinusoidal vibrations 2 15 8 Hz 2 54 mm peak ...

Page 94: ...voltage range is 8V to 32V Max current 105mA 8VDC Connector 1 x DSUB9 Female 1 x DSUB9 Male Fuse Internal automatic recovering poly fuse Temperature 25 C to 55 C operating 40 C to 80 C storage Relative humidity 95 non condensing at 40 C Vibration operational Random vibrations 5 20 Hz 0 005 g Hz 20 150 Hz 3 dB oct 0 5 g rms Sinusoidal vibrations 2 15 8 Hz 2 54 mm peak ampl 10 100 Hz 1 0 g peak acce...

Page 95: ... 21 Signal Color Data White Data Blue 9V Red GND Black Table 21DeviceNet color code definition for TT 3000E The DeviceNet cable sizes are listed in Table 22 AWG sizes can vary between manufacturers Type Red Black Blue White Usage Thick 15 18 Trunk line Med 16 20 Trunk line Thin 22 22 Drop line Thin High Flex 22 24 Drop line Table 22 DeviceNet cable size definition A typical DeviceNet cable cross s...

Page 96: ...d are Allen Bradley Rockwell DeviceNet T Connector 1485 P1N5 MN5R1 BradConnectivity Woodhead Media Bus Drop TEE DN3020 Figure 55 Rockwell DeviceNet T Connector The termination plugs tested are Brad Connectivity Woodhead female termination resistor DN150 Brad Connectivity Woodhead male termination resistor DN100 96 97 ...

Page 97: ...on Manual The field installable cable connectors tested are Brad Connectivity Woodhead female conn field install 1A5000 34DN Brad Connectivity Woodhead male conn field install 1A5006 34DN Figure 56 Field installable DeviceNet connector 97 97 ...

Reviews: