TT-3000E mini-C GMDSS System
Installation Manual
9.3
TT-3042C
S
PECIFICATIONS
Model TT-3042C,
Remote Alarm/Distress Box
General Specifications
The unit is in full compliance with the
Inmarsat CN114, IEC 60945 and Wheel
Mark specifications.
Dimensions (H x W x D)
49 mm x 95 mm x 99 mm
Weight 0.32
Kg
Mountings
Wall mounting, 4 holes Ø4.0 mm
Mounting bracket for console, 4 holes
Ø4.0 mm
Power requirements
7.5V - 12V DC,
Standby: 0.1W @ 9V
Max.:
Cable length / Type
Max. 100m / 8 wire, screened signal
cable, 0.25mm
2
or better.
Connector Internal
screw
terminals
Distress/MES Fault Relay
Max. switching: 2A or 60W or 220V AC
Distress Relay jumpers
Enable; W1: 1-2,
Disable; W1: 2-3 ††
Activated:
Shorted; W2: 1-2 ††,
Open;
W2:
2-3
MES Fault Relay jumpers
Enable; W3: 1-2,
Disable; W3: 2-3 ††
Activated:
Open;
W4: 1-2 ††,
Shorted;
W4:
2-3
Temperature
-25°C to 55°C operating,
-40°C to 80°C storage
Relative humidity
95% non-condensing at 40°C
Vibration operational
Random vibrations:
5-20 Hz:0.005 g²/Hz
20-150 Hz:-3 dB/oct
(0.5
g
rms.)
Sinusoidal vibrations: 2-15.8 Hz: 2.54 mm
peak
ampl.
10-100 Hz: 1.0 g
peak
acceleration
Vibration survival
Random vibrations:
5-20 Hz:0.05g²/Hz
20-150 Hz:-3 dB/oct
(1.7g
rms.)
Sinusoidal vibrations: 2-15.8 Hz:2.54 mm
peak
ampl.
10-100
Hz:
1.0g
peak
acceleration
Shock Half
sine:
20g/11ms
Table 18 TT-3042C Technical Specifications
††: Factory setting
92/97
Summary of Contents for SAILOR TT-3000E mini-C GMDSS System
Page 2: ...TT 3000E mini C GMDSS System Installation Manual This page is intentionally left blank 2 97 ...
Page 4: ...TT 3000E mini C GMDSS System Installation Manual This page is intentionally left blank 4 97 ...
Page 61: ...TT 3000E mini C GMDSS System Installation Manual Figure 37 TT 3606E Mounting Bracket 61 97 ...