Set up PFR500 or PFR600 network settings
28
PVS 3000 & PVS3500 Installation Guide
23 February 2004
Press Enter to accept defaults.
NOTE: Default value may
appear different than shown
here.
How long (in seconds) should CPU delay before starting up? [10]
RAID controller configuration
is displayed showing your
settings.
NETWORK INTERFACE PARAMETERS:
IP address on LAN is 192.168.0.11
LAN interface's subnet mask is 255.255.255.0
COMMUNICATION PARAMETERS:
Serial channels will use a baud rate of 9600
HARDWARE PARAMETERS:
This board's MAC Address is 0:20:46:11:14:23
APPLICATION PARAMETERS:
Boot Ciprico Network Server
Mail and SNMP notification will occur for Hardware changes,
Warnings, and Critical events.
SNMP TRAP CONFIGURATION:
TRAP COMMUNITY NAME 'public'
TRAP MANAGER #1 IP Address 192.168.0.10
After board is reset, start-up code will wait 10 seconds
Type
c
, then press Enter.
(M)odify any of this or (C)ontinue? [M]
Wait for non-volatile storage
update.
Updating non-volatile storage. This may take a while...Done
Wait for initialization.
NOTE: If the network cable
is not connected, the console
stops at the message
“Waiting for Ethernet
Link...”. If you cannot
connect network cabling at
this time, cycle the power on
the PFR500 Controller
chassis, then continue with
this procedure.
Initializing Enclosure Services Interface......Done
Instructions
Text entered and displayed in terminal window
c
Summary of Contents for GRASS VALLEY Profile XP PVS3000
Page 16: ...16 Set up the RAID Storage PFR700 E Local storage only 23 February 2004...
Page 18: ...Start your system 18 PVS3000 PVS3500 Installation Guide 23 February 2004...
Page 24: ...Create a video file system 24 PVS3000 PVS3500 Installation Guide 23 February 2004...
Page 46: ...Select an RS 422 control protocol 46 PVS3000 PVS3500 Installation Guide 23 February 2004...
Page 48: ...48 PVS3000 PVS3500 Installation Guide 23 February 2004...