7 - USING THE GROUP SELECTOR

Your remote control can manage 4 groups of 
3 channels each. Move the group selector to 
positions I, II, III, or IV to choose which group to 
choose which group of devices to control.

Notes:

•  Each channel can operate up to 5 different 

devices.

•  The 3-channel on and off buttons at the base 

of the remote control only affect the devices 
paired to the currently selected group.

8 - REPLACING THE REMOTE CONTROL 
BATTERY

If you notice that the range of your remote control 
is decreasing, the battery should be replaced. If 
the remote control is paired with a Thombox, the 
Thombox is informed of this.
Use a 3V CR2032 battery.

Under normal conditions, battery life is 
approximately one year.

9 - MOTOR SAFETY FEATURES

The motor includes:

•  A thermal safety mechanism to prevent 

damage to the motor.

•  A force sensor to avoid any damage to the 

shutter.

The  thermal  safety  mechanism  is  designed  to 
prevent  the  electric  shutter  motor  from  damage 
(when the motor is overworked). This thermal safety 
mechanism  is  triggered  if  the  shutter  operates  for 
over 4 minutes, or at intervals which are too close 
together to allow the motor to cool down. Wait 10-
15  minutes  and  the  shutter  will  return  to  normal 
operation.  The  shutter  will  not  move  when  the 
thermal safety mechanism is in place.

The force sensor is designed to prevent any damage 
to the shutter in the event of sudden strain (when the 
motor is stuck). The force sensor stops movement if 
the shutter becomes stuck during its course. If this 
does  happen,  identify  what  is  causing  the  shutter 
to stick and remove the problem (sticking along the 
course or need for grease/configuration, damage to 
the shutter itself, something in the way) before the 
shutter can function normally again.

21

EN

F - uSiNG THE prOduCT

30Nm drive kit 

for rolliNg shutters aNd bliNds

Summary of Contents for 500014

Page 1: ...EN 30Nm drive kit for rolling shutters and blinds ref 500014 70Kg 3m www thomsonbox eu v2...

Page 2: ...08 D INSTALLATION 09 1 INSTALLING THE TUBULAR MOTOR 09 2 INSTALLING THE MANAGEMENT MODULE 16 3 CONNECTING THE MANAGEMENT MODULE 16 4 REMOTE CONTROL 17 E CONFIGURATION 18 1 PROGRAMMING 18 2 SETTING MOT...

Page 3: ...7 USING THE GROUP SELECTOR 21 8 REPLACING THE REMOTE CONTROL BATTERY 21 9 MOTOR SAFETY FEATURES 21 G FAQ 22 H TECHNICAL AND LEGAL INFORMATION 23 1 technical characteristics 23 2 warranty 24 3 help and...

Page 4: ......

Page 5: ...eplaced by an original part and nothing else Periodically check the installation for any signs of wear or damage to the shutter the mechanical parts and the mounting Do not use the device if repairs o...

Page 6: ...r tube connector ring 4 Head adaptor 1 End stop configuration button 2 Shutter tube connector ring location 3 Output shaft only driven part in the whole motor 5 Snap ring 6 Pin 7 Management module 8 R...

Page 7: ...Terminal blocks for connecting to the motor and the mains supply 30Nm drive kit for rolling shutters and blinds 4 remote control 2 4 3 5 1 6 7 1 System on indicator light 2 Channel 1 2 3 on buttons 3...

Page 8: ...ghting etc openers shutter motors garage doors etc and manage your energy use heating and electricity consumption with just a few clicks on a computer touchscreen tablet or smartphone from anywhere in...

Page 9: ...9 EN D INSTALLATION 30Nm drive kit for rolling shutters and blinds 1 INSTALLING THE TUBULAR MOTOR Remove the rolling shutter cover...

Page 10: ...e the shutter housing drive plate Remove all obstacles so that there is a flat surface Strengthen if required Note the axis of the axle that the motor will replace then place the motor anchor plate al...

Page 11: ...11 EN D INSTALLATION Align the slots on the ring with the motor collar Attach the head adaptor 30Nm drive kit for rolling shutters and blinds...

Page 12: ...tube must not present any obstacle which prevents the motor being inserted or rotating e g screw attaching the shutter to the tube If necessary remove any obstacles from the tube Insert the motor as f...

Page 13: ...13 EN D INSTALLATION Attach the anchor plate 30Nm drive kit for rolling shutters and blinds...

Page 14: ...and blinds Ensure that the end stop setting button located at the end of the motor remains accessible Where possible reattach the shutter in an intermediate position neither completely open nor comple...

Page 15: ...15 EN D INSTALLATION Thread the power supply cable as shown Ensure that it cannot become trapped in any moving parts 30Nm drive kit for rolling shutters and blinds...

Page 16: ...pped in any moving parts 3 CONNECTING THE MANAGEMENT MODULE WARNING all wiring must take place when the system is isolated circuit breaker set to OFF 3 5 M 3 5 Notes How the raising and lowering phase...

Page 17: ...17 EN D INSTALLATION 4 REMOTE CONTROL Remove the tab on the back of the remote control to connect the battery 30Nm drive kit for rolling shutters and blinds...

Page 18: ...button is difficult to access due to lack of space or proximity to moving parts use a narrow tool to safely press the button To set the end stops you will need to operate the shutter briefly If your...

Page 19: ...time for 3 seconds The LED on the remote control blinks red Then place the device to be controlled into pairing mode Refer to the device s user guide to find out how to do this Note You can pair up t...

Page 20: ...ote control with a Thombox it does not appear in the dashboard but is available in the rule creator in the Contr les Controls section You can then create rules which you can trigger using the buttons...

Page 21: ...or A force sensor to avoid any damage to the shutter The thermal safety mechanism is designed to prevent the electric shutter motor from damage when the motor is overworked This thermal safety mechani...

Page 22: ...correct wiring The thermal safety mechanism is engaged The force sensor is engaged Check the wiring Wait 15 minutes to give the thermal safety mechanism time to cool down and disengage Identify the bl...

Page 23: ...er Consumption at rated strength Maximum shutter surface Operating temperature Maximum power Assigned operating duration ARW 868 3MHz protocol ARW 868 3MHz protocol Tubular 230V AC motor epicyclic red...

Page 24: ...t is not to specification If the problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may ref...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...is a TECHNICOLOR S A brand used under licence by Avidsen France S A S 32 rue Augustin Fresnel 37170 Chambray les Tours France...

Reviews: