WARNING:  Do not let the shutter move freely 
when the end stops have not been correctly set.

1 - PROGRAMMING

To pair the management module and the remote 
control:

•  On the remote control, press and hold the 'on' 

and 'off' buttons for the channel you want to 
use (1 to 3) at the same time for 3 seconds. 
The LED on the remote control blinks red.

•  While the remote control LED is blinking, hold 

down the pairing button on the management 
module for at least 3 seconds. Pairing is now 
complete.

2 - SETTING MOTOR END STOPS

Before using your shutter, it is essential that you 
set the upper and lower end stop positions for your 
shutter.

WARNING

•  During this step, the shutter may not stop by 

itself when it is fully open or closed. Read the 
following instructions carefully before adjusting 
the settings.

•  To set the motor end stops, you will need to 

press the motor button. If this button is difficult 
to access due to lack of space or proximity 
to moving parts, use a narrow tool to safely 
press the button.

•  To set the end stops, you will need to operate 

the shutter briefly. If your shutter is completely 
open, begin by setting the lower end stop. If 
your shutter is completely closed, begin by 
setting the upper end stop.

•  If your shutter opens when you ask it to 

close and vice versa, pressing briefly on the 
management module's pairing button will 
invert raising and lowering.

To set the lower end stop (closing):

•  Lower the shutter using your remote control, 

using the off button ('OFF') on the channel that 
you used when pairing.

•  Immediately press the motor button: the 

shutter stops.

•  Press the motor button again. For as long as 

you hold this button down, the shutter will 
lower. Once the shutter is completely closed, 
press the on button ('ON') for the channel that 
you used during pairing. The current position 
is recorded as the lower end stop and the 
configuration is finished.

EN

18

E - CONFiGurATiON

30Nm drive kit 
for rolliNg shutters aNd bliNds

Summary of Contents for 500014

Page 1: ...EN 30Nm drive kit for rolling shutters and blinds ref 500014 70Kg 3m www thomsonbox eu v2...

Page 2: ...08 D INSTALLATION 09 1 INSTALLING THE TUBULAR MOTOR 09 2 INSTALLING THE MANAGEMENT MODULE 16 3 CONNECTING THE MANAGEMENT MODULE 16 4 REMOTE CONTROL 17 E CONFIGURATION 18 1 PROGRAMMING 18 2 SETTING MOT...

Page 3: ...7 USING THE GROUP SELECTOR 21 8 REPLACING THE REMOTE CONTROL BATTERY 21 9 MOTOR SAFETY FEATURES 21 G FAQ 22 H TECHNICAL AND LEGAL INFORMATION 23 1 technical characteristics 23 2 warranty 24 3 help and...

Page 4: ......

Page 5: ...eplaced by an original part and nothing else Periodically check the installation for any signs of wear or damage to the shutter the mechanical parts and the mounting Do not use the device if repairs o...

Page 6: ...r tube connector ring 4 Head adaptor 1 End stop configuration button 2 Shutter tube connector ring location 3 Output shaft only driven part in the whole motor 5 Snap ring 6 Pin 7 Management module 8 R...

Page 7: ...Terminal blocks for connecting to the motor and the mains supply 30Nm drive kit for rolling shutters and blinds 4 remote control 2 4 3 5 1 6 7 1 System on indicator light 2 Channel 1 2 3 on buttons 3...

Page 8: ...ghting etc openers shutter motors garage doors etc and manage your energy use heating and electricity consumption with just a few clicks on a computer touchscreen tablet or smartphone from anywhere in...

Page 9: ...9 EN D INSTALLATION 30Nm drive kit for rolling shutters and blinds 1 INSTALLING THE TUBULAR MOTOR Remove the rolling shutter cover...

Page 10: ...e the shutter housing drive plate Remove all obstacles so that there is a flat surface Strengthen if required Note the axis of the axle that the motor will replace then place the motor anchor plate al...

Page 11: ...11 EN D INSTALLATION Align the slots on the ring with the motor collar Attach the head adaptor 30Nm drive kit for rolling shutters and blinds...

Page 12: ...tube must not present any obstacle which prevents the motor being inserted or rotating e g screw attaching the shutter to the tube If necessary remove any obstacles from the tube Insert the motor as f...

Page 13: ...13 EN D INSTALLATION Attach the anchor plate 30Nm drive kit for rolling shutters and blinds...

Page 14: ...and blinds Ensure that the end stop setting button located at the end of the motor remains accessible Where possible reattach the shutter in an intermediate position neither completely open nor comple...

Page 15: ...15 EN D INSTALLATION Thread the power supply cable as shown Ensure that it cannot become trapped in any moving parts 30Nm drive kit for rolling shutters and blinds...

Page 16: ...pped in any moving parts 3 CONNECTING THE MANAGEMENT MODULE WARNING all wiring must take place when the system is isolated circuit breaker set to OFF 3 5 M 3 5 Notes How the raising and lowering phase...

Page 17: ...17 EN D INSTALLATION 4 REMOTE CONTROL Remove the tab on the back of the remote control to connect the battery 30Nm drive kit for rolling shutters and blinds...

Page 18: ...button is difficult to access due to lack of space or proximity to moving parts use a narrow tool to safely press the button To set the end stops you will need to operate the shutter briefly If your...

Page 19: ...time for 3 seconds The LED on the remote control blinks red Then place the device to be controlled into pairing mode Refer to the device s user guide to find out how to do this Note You can pair up t...

Page 20: ...ote control with a Thombox it does not appear in the dashboard but is available in the rule creator in the Contr les Controls section You can then create rules which you can trigger using the buttons...

Page 21: ...or A force sensor to avoid any damage to the shutter The thermal safety mechanism is designed to prevent the electric shutter motor from damage when the motor is overworked This thermal safety mechani...

Page 22: ...correct wiring The thermal safety mechanism is engaged The force sensor is engaged Check the wiring Wait 15 minutes to give the thermal safety mechanism time to cool down and disengage Identify the bl...

Page 23: ...er Consumption at rated strength Maximum shutter surface Operating temperature Maximum power Assigned operating duration ARW 868 3MHz protocol ARW 868 3MHz protocol Tubular 230V AC motor epicyclic red...

Page 24: ...t is not to specification If the problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may ref...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...is a TECHNICOLOR S A brand used under licence by Avidsen France S A S 32 rue Augustin Fresnel 37170 Chambray les Tours France...

Reviews: