3.
Carefully remove the large outer filter element
from the filter cannister, as shown in
, and
discard the outer filter element.
4.
Remove the small inner filter element from the
filter cannister, as shown in
, and discard
the inner filter element.
5.
Install a new inner filter element in the filter can-
nister. Ensure that the element is fully seated.
f130183
06/04/2020
1
2
1.
O-Ring
2.
Filter
Fig. 12, Installing the Filter Element in the Housing
f130185
06/05/2020
1
1.
Separator Housing (first section)
Fig. 13, Installing the First Section of the Separator
Housing
f130186
06/05/2020
Fig. 14, New O-Ring Installed on the End Cap
f130187
06/05/2020
Six end cap bolts are used to attach the end cap to the
compressor. Only three of the bolts are shown.
Fig. 15, Installing the End Cap