Preliminary
THCV245A_Rev.0.90_E
Copyright©2020 THine Electronics, Inc.
THine Electronics, Inc.
Security C
40/67
6.21 Sub-Link Watch Dog Timer
Sub-Link Watch Dog Timer (WDT) is installed to monitor status. When Sub-Link single transaction started but
was not normally ended in time, WDT report Interrupt event of “R_INT_SLINK_TMOUT”.
Table 34.
Sub-Link WDT setting
M
aster
Master
Slave
or
S
lav e
Addr(h) Addr(h)
Bits
Register
w idth
R/W
Description
Default
related
0x0018 0x0098
[7:5]
reserved
3
-
-
-
-
0x0018 0x0098
[4]
R_SLINK_WD_EN
1
RW
Sublink WDT Enable
0:Disable
1:Enable
1'b1
MS
0x0018 0x0098
[3:2]
reserved
2
-
-
-
-
0x0018 0x0098
[1:0]
R_SLINK_WD_TIM_UP
2
RW
Sublink WDT time parameter
2'd0
MS
0x0019 0x0099
[7:0]
R_SLINK_WD_TIM_DN
8
RW
Sublink WDT time =64×(256×R_SLINK_WD_TIM_UP<1:0> +
R_SLINK_WD_TIM_DN<7:0>+1) ×tOSC
8'd187
MS