INSTALLATION
14
3.5.
Mounting the burner
The burner is mounted on the lower door flange. First mount the insulation gasket and then
the burner with the four screws included, like in Error! Reference source not found.. Make
ure that the burner tube is correctly positioned inside the fire chamber, and the door opens
normally.
Fig 7.
Mounting the burner
The pellet silo must be positioned normally from the right side of the boiler, so that the door
opens easily. It must be positioned as close to the boiler as possible so that the feeder length
will be sufficient.
The pellet feeder must be inserted in the silo before you fill it with pellets. The feeder must be
positioned with inclination, optimum at 30-45
o
to the floor. The pellet feeder cannot be
positioned at angle more than 45
o
, nor vertically or horizontally! After positioning
secure it so that it doesn’t move. The connection between the pellet feeder and the burner is
done by a flexible hose. This hose must also have an inclination and be tightened so that it
allows free fall of the pellets towards the burner. The connection of the hose with the burner
and the feeder must be air-tight. Use the tighteners provided.
The positioning of the pellet feeder and the silo are very important to the
burner’s operation! If not positioned correctly it can cause malfunction and stop of
the burner.
Legend
1
Burner mounting flange
2
Burner gasket
3
Fixing screws
4