Page 21
e manutenzione
11
13
12
14
DAYS
DATA
MON
2
3
5
4
7
6
1
8
00 : 00
LEGENDA
KEY
Zona del display dove viene visualizzato il giorno corrente
(per esempio 3 pallini = mercoledì)
Display area in which the current day is displayed (for example,
3 dots = Wednesday)
Zona del display dove vengono visualizzati fasi di
funzionamento, ora,. . .
Display area in which the operation steps are displayed, time...
Indicatore livello di ventilazione
Ventilation level indicator
"Thermocomfort On" ovvero connesso
"Thermocomfort On" i.e. connected
Indicatore livello di combustione
Combustion level indicator
Riarmo
Reset
Spia motoriduttore
Ratio motor led
5.1.2 APPLIANCE REAR PANEL
A description of the functions of the buttons and LEDs on the rear panel:
(11) Main switch 0-1
(12) Electrical power outlet 220-240V 50 Hz
(13) Overtemperature reset thermostat button cap
In the event of overtemperature this safety thermostat stops the loading of
pellets. To restart the appliance you need to wait until it cools down, then
verify the cause for the overheating, remove the cause, unscrew the
protective cap and press the button (13).
(14) Feed motor test indicator light When the pellet screw feeder is set
in motion the light must come on.
5.2 DAY AND TIME SETTING
The appliance must be energised and the rear switch in position "1". The
words START or WORK or OFF could be present on the display (7). To set the time and the day of the week carry out the
procedures described below. Press button (6) once;
the word DATA will appear on the display followed
by the words illustrated in the figure on the left. To
set the day press arrow button (3) and/or (4)
repeatedly until the desired day appears: (MON and
one dot for Monday -- TUE and two dots for Tuesday
-- WED and 3 dots for Wednesday -- THU and 4 dots
for Thursday -- FRI and 5 dots for Friday -- SAT and
6 dots for Saturday -- SUN and 7 dots for Sunday).
Then confirm the day by pressing the key (1). The 2
digits representing the hours will start flashing in the
display: it is possible to select the present hour using the arrow keys (3) and/or (4); the selection must be confirmed by pressing key
(1). The 2 digits indicating the minutes will start flashing: it is possible to select the present minutes using the arrow keys (3) and/or
(4), the selection must be confirmed by pressing the key (1). The day and time setting is now completed.
5.3 ON/OFF PROGRAMMING
The generator must be energised and the rear switch in position "1". The words START or WORK or OFF could be present on the
display (7).
DAYS
CRONO
MON
3
2
5
4
8
1
7
6
DAYS
CRONO
MON
3
2
5
4
8
1
7
6
00: 00
ON 1
Summary of Contents for DORICA MAIOLICA
Page 1: ......
Page 4: ...Page 4 e manutenzione ...
Page 5: ...Page 5 e manutenzione EC DECLARATION OF CONFORMITY ...
Page 12: ...Page 12 e manutenzione Figura 1 E C B A A D Figura 2 E E F G G ...
Page 14: ...Page 14 e manutenzione Figura 4 2 Figura 7 C Figura 6 5 Figura 5 3 4 ...
Page 16: ...Page 16 e manutenzione Figura 2 A B 1 A Figura 3 A 1 A Figura 4 2 Figura 5 3 ...
Page 17: ...Page 17 e manutenzione Figura 8 D 10 Figura 9 C 10 Figura 6 5 Figura 7 C ...
Page 32: ...Page 32 e manutenzione Figura 2 B B A V Figura 3 V1 ...
Page 33: ...Page 33 e manutenzione Figura 4A Figura 4 B ...
Page 34: ...Page 34 e manutenzione Figura 4 C Figura 5 A 1 ...
Page 56: ...Page 56 e manutenzione NOTES ...