background image

7

3. ensure that the mounting is according with the information’s  

on the enclosure.

4. fix the dcc with the anchors provided for the type of surface.
5. check that the dcc is adequately fixed to the wall or ceiling.

step 4: ConduCtor Connexions

consult the diagram on the next page for all details on the cable 
connections configuration. this diagram is also found under the dcc 
cover. 

Current transformers (Ct) installation and connections

1. open the ct.
2. install the ct around the main power cable of the panel.
3. check the correct polarity on the cts.
4. connect the ct cables to the terminal block, provided for  

that purpose, inside the dcc.

extension of current transformers’s wire

if the dcc is installed remotely from the panel, it is possible to extend 
the wiring supplied with the current transformers up to a maximum  
of 25 feet. 
additional wire must be 600V rated, minimum 18 aWg (1mm),  
4 conductors shielded twisted (ex: ft4 shield. 4c fas #18  
or equivalent).

step 5-a: dip switCH proGramminG  
For main power supply 

1. identify the set-up section on the dcc.
2. set up the section as per the layout corresponding to the main 

power supply:

  

models 

main power supply

 

 

60a  70a  80a  90a  100a 125a 150a 200a 

dcc-9-30a

  

✓ 

✓ 

✓ 

✓ 

✓ 

✓ 

✓ 

✓ 

dcc-9-40a

 

 

✗ 

 

✓ 

✓ 

✓ 

✓ 

✓ 

✓ 

dcc-9-50a

 

 

✗ 

✗ 

✗ 

 

✓ 

✓ 

✓ 

✓ 

dcc-9-60a

   

✗ 

✗ 

✗ 

✗ 

 

✓ 

✓ 

✓ 

step 5-B: ConFiGuration oF tHe transFormer  
voltaGe at 208v

 (only for application at 208V, single phase)

1. locate the orange cable connected  

to the 240V terminal (factory setting).

2. Unplug the orange cable from  

the 240V terminal.

3. plug the orange cable to the 208V terminal.

T

24V

240V

208V

COM

TRANSFORMER

TRANSFORMATEUR

50VA/240/208V

Orange

T

24V

240V

208V

COM

TRANSFORMER

TRANSFORMATEUR

50VA/240/208V

Orange

i

Warranty automatically void if electrical power is supplied to the 

dcc and the transformer is not set at the appropriate voltage.

warninG

step 6: start-up 

dCC power supply

1. supply electrical power to the dcc.
2. Wait ten (10) seconds.
3. check if the contactor is switched on.
4. check the pilot light:

Green

 at all time: compliant installation, go to the next step.

red

: refer to the lights code section.

Summary of Contents for DCC-10 series

Page 1: ...igned by Design par Main power supply 240 208V Single Phase 60A 70A 80A 90A 100A 125A 150A 200A alimentation principale 240 208V Monophas 60A 70A 80A 90A 100A 125A 150A 200A approved market North Amer...

Page 2: ...2...

Page 3: ...ECTRIQUE and its licensors This installation manual cannot be modified reproduced or copied without a prior writ ten authorisation from THERMOLEC LTE E RECHARGE V HICULE LECTRIQUE and its licensors Ad...

Page 4: ...e that the electric power source is adequate for the use of one or more DCC Do not use any cleaning solvents to clean the DCC Charge controller for electric vehicle Limited warranty 1 THERMOLEC LTE E...

Page 5: ...ation through a 30A 40A 50A or 60A 240 208V AC circuit breaker L1 L2 and ground The DCC is equipped with a Square D cir cuit breaker QU0230 QU0240 QU0250 or QU0260 Trip Percentage TP The DCC Charge co...

Page 6: ...installed incorrectly WARNING Ceiling installation The installation may be done in any direction DCC installation Step 1 Check the package contents 1 x Ceiling mounting support 1 INSTALLATION MANUAL...

Page 7: ...FT4 SHIELD 4C FAS 18 or equivalent Step 5 A Dip switch programming for main power supply 1 Identify the set up section on the DCC 2 Set up the section as per the layout corresponding to the main powe...

Page 8: ...and operating DRAWING NO DCC 10 SPLITTER BOX CONTROLLER TITLE DCC 10 SPLITTER BOX CONTROLLER BOITIER DE CONTROLE DCC 10 DATE 18 04 2018 V5 PER DCC ELECTRONIC CONTROLLER CONTROLEUR ELECTRONIQUE DCC PB...

Page 9: ...ures of the installation at support dcc technology and then call 1 833 717 1355 OFF No power Check the power source Charging station power supply 1 Put the circuit breaker in the ON position 2 Check i...

Page 10: ...des mati res propos de ce manuel 10 Information de s curit 10 Sp cifications 12 Caract ristiques 12 Exemple d installation 13 Installation du DCC 13 Utilisation 17 Maintenance 17 Code de lumi re 17 f...

Page 11: ...staller le DCC Contr leur de charge pour v hicule lectrique proxi mit de mat riaux inflammables explo sifs ou combustibles produits chimiques et des vapeurs Ne pas installer le DCC Contr leur de charg...

Page 12: ...justement programmable qui permet de prot ger une distribution lectrique en fonction de son disjoncteur principale Il permet de pr venir la surcharge d une distribution lectrique en coupant momentan m...

Page 13: ...ps de reprise de 15 minutes exemple d installation Installation du DCC tape 1 V rifier le contenu de la bo te I Pour visionner notre vid o d installation visitez le www dcc technology fr VID O D INSTA...

Page 14: ...ntation principale de l entr e lectrique 3 V rifier la polarit des CT 4 Raccorder les c bles des CT aux borniers l int rieur du DCC 10 pr vus cet effet tape 2 Pr paration l installation 1 Couper l ali...

Page 15: ...g and operating DRAWING NO DCC 10 SPLITTER BOX CONTROLLER TITLE DCC 10 SPLITTER BOX CONTROLLER BOITIER DE CONTROLE DCC 10 DATE 18 04 2018 V5 PER DCC ELECTRONIC CONTROLLER CONTROLEUR ELECTRONIQUE DCC P...

Page 16: ...uement annul e si le DCC est aliment sans que le transforma teur n ait t configur ad quatement ATTENTION Extension des fils des transformateurs de courant Les transformateurs de courant qui sont fourn...

Page 17: ...ert La borne de recharge est aliment e en lectricit Vert La borne de recharge est aliment e en lectricit La charge totale exc de 80 Si la charge exc de 80 pendant la p riode pr d termin e l alimentati...

Reviews: