background image

6

the dcc can be mounted:
- on a ceiling 
- on a wall 
note: the dcc controller must be mounted so that  
the nameplate remains visible at all times. 
do not install the dcc:
- outdoor
- in a location with high level of risk.
- nearby inflammable materials, explosives 
  or fuels, chemical products and vapors. 

3. before installation, check the dcc mounting position.

wall installation 

refer to the information on the  
enclosure to insure proper installation. 

step 3: installation

Ceiling installation 

1. remove the 4 cover screws.
2. fix the ceiling mounting support on the dcc.
3. lift the dcc using the ceiling mounting support.
4. position the dcc at the intended location.
5. fix the dcc with the anchors for the type of surface. 
6. check that the dcc is adequately fixed to the wall or ceiling.
7. remove the ceiling mounting support.

wall installation

1. remove the 4 cover screws.
2. position the dcc at the intended location.

i

Warranty automatically void if the dcc is installed incorrectly.

warninG

Ceiling installation

the installation may be  
done in any direction.

dcc installation

step 1: CHeCk tHe paCkaGe Contents 

1 x ceiling mounting support

1

INSTALLATION MANUAL

MANUEL D’INSTALLATION

MODELS 

MODÈLES

DCC-10-40A, DCC-10-50A, DCC-10-60A

Manufactured by

Manufacturé par

Designed by

Design par

MAIN POWER SUPPLY 

 

240/208V, Single Phase 

100A - 125A - 150A - 200A

ALIMENTATION PRINCIPALE

  

240/208V Monophasé 

100A - 125A - 150A - 200A 

APPROVED MARKET 

 

North America

MARCHÉ AGRÉÉ

  

Amérique du Nord

JUNE 2017 

 JUIN 2017 V3

ENGLISH

FRANÇAIS

Read and save these instructions

Lire et garder ces instructions

1 x installation manual

i

to access our installation video, visit our website www.dcc.technology

1 x dcc

installation video

2 x current transformer (ct)

step 2: preparations For installation

1. disconnect the main power 
2. select the dcc intended location.

select an intended location preferably less than 6 feet away from 
the electric panel (power source). the current transformers sup-
plied have a wiring of 6 feet in length, but can be extended to 18 
feet’s (see the section Step 4: Conductor connexions for the exten-
sion details).

Summary of Contents for DCC-10 series

Page 1: ...igned by Design par Main power supply 240 208V Single Phase 60A 70A 80A 90A 100A 125A 150A 200A alimentation principale 240 208V Monophas 60A 70A 80A 90A 100A 125A 150A 200A approved market North Amer...

Page 2: ...2...

Page 3: ...ECTRIQUE and its licensors This installation manual cannot be modified reproduced or copied without a prior writ ten authorisation from THERMOLEC LTE E RECHARGE V HICULE LECTRIQUE and its licensors Ad...

Page 4: ...e that the electric power source is adequate for the use of one or more DCC Do not use any cleaning solvents to clean the DCC Charge controller for electric vehicle Limited warranty 1 THERMOLEC LTE E...

Page 5: ...ation through a 30A 40A 50A or 60A 240 208V AC circuit breaker L1 L2 and ground The DCC is equipped with a Square D cir cuit breaker QU0230 QU0240 QU0250 or QU0260 Trip Percentage TP The DCC Charge co...

Page 6: ...installed incorrectly WARNING Ceiling installation The installation may be done in any direction DCC installation Step 1 Check the package contents 1 x Ceiling mounting support 1 INSTALLATION MANUAL...

Page 7: ...FT4 SHIELD 4C FAS 18 or equivalent Step 5 A Dip switch programming for main power supply 1 Identify the set up section on the DCC 2 Set up the section as per the layout corresponding to the main powe...

Page 8: ...and operating DRAWING NO DCC 10 SPLITTER BOX CONTROLLER TITLE DCC 10 SPLITTER BOX CONTROLLER BOITIER DE CONTROLE DCC 10 DATE 18 04 2018 V5 PER DCC ELECTRONIC CONTROLLER CONTROLEUR ELECTRONIQUE DCC PB...

Page 9: ...ures of the installation at support dcc technology and then call 1 833 717 1355 OFF No power Check the power source Charging station power supply 1 Put the circuit breaker in the ON position 2 Check i...

Page 10: ...des mati res propos de ce manuel 10 Information de s curit 10 Sp cifications 12 Caract ristiques 12 Exemple d installation 13 Installation du DCC 13 Utilisation 17 Maintenance 17 Code de lumi re 17 f...

Page 11: ...staller le DCC Contr leur de charge pour v hicule lectrique proxi mit de mat riaux inflammables explo sifs ou combustibles produits chimiques et des vapeurs Ne pas installer le DCC Contr leur de charg...

Page 12: ...justement programmable qui permet de prot ger une distribution lectrique en fonction de son disjoncteur principale Il permet de pr venir la surcharge d une distribution lectrique en coupant momentan m...

Page 13: ...ps de reprise de 15 minutes exemple d installation Installation du DCC tape 1 V rifier le contenu de la bo te I Pour visionner notre vid o d installation visitez le www dcc technology fr VID O D INSTA...

Page 14: ...ntation principale de l entr e lectrique 3 V rifier la polarit des CT 4 Raccorder les c bles des CT aux borniers l int rieur du DCC 10 pr vus cet effet tape 2 Pr paration l installation 1 Couper l ali...

Page 15: ...g and operating DRAWING NO DCC 10 SPLITTER BOX CONTROLLER TITLE DCC 10 SPLITTER BOX CONTROLLER BOITIER DE CONTROLE DCC 10 DATE 18 04 2018 V5 PER DCC ELECTRONIC CONTROLLER CONTROLEUR ELECTRONIQUE DCC P...

Page 16: ...uement annul e si le DCC est aliment sans que le transforma teur n ait t configur ad quatement ATTENTION Extension des fils des transformateurs de courant Les transformateurs de courant qui sont fourn...

Page 17: ...ert La borne de recharge est aliment e en lectricit Vert La borne de recharge est aliment e en lectricit La charge totale exc de 80 Si la charge exc de 80 pendant la p riode pr d termin e l alimentati...