PELLING ECO
34
6.4
Every six months
6.4.1
Cleaning the flue gas exhaust chamber
Turn the boiler off and wait until it has been cooled.
Unscrew the two nuts from the back of the flue gas exhaust chamber as
shown.
Remove the plate that closes the gas flue box.
Clean out the accumulated sediments into a fire-resistant container using the
poker that came with the boiler.
Place the plate back onto the flue gas exhaust chamber and attach it with the
nuts.