PELLING ECO
30
5.8
Parameter setting
To provide flawless operation of the boiler, the control unit has possibility of
adjusting the certain parameters that affect the combustion and ignition. The
user has the option to reduce the dosage and increase the power of the fan in
stage work, and reduce dosage in the stage ignition.
Method to adjust the parameters
On the display needs to shows the time.
Press the Menu button and hold it for 3 seconds. After that, the display shows
the PASSWORD. Password is 70101
Entering a password we perform
↓
↑
keys. After you select the desired number
confirm by pressing MENU, then again press the MENU button to move to the
next number. At the end when we entered all digits press the MENU key and
hold it for 3 seconds.
Between the parameters we move using the arrow keys, to enter the changes,
press the MENU button. To confirm the entered parameters hold for 3 seconds
press the MENU button.
Parameter:
- MATERIAL - dosing in the phase of work (changing for all of power). It is
only possible to reduce the dosage from 0 to -15%
- FAN - fan in the stage work (changing for all of power). It is only possible to
increase from 0 to +15%
- IGNIT. - Dosing in the phase of ignition. It is only possible to reduce the
dosage from 0 to -15%
To exit the setting hold the on / off switch (0 / I) for 3 seconds
Summary of Contents for PELLING 25 ECO
Page 2: ...2...
Page 15: ...PELLING ECO 15 4 2 Technical data...
Page 18: ...PELLING ECO 18...
Page 19: ...PELLING ECO 19...
Page 20: ...PELLING ECO 20...
Page 38: ...PELLING ECO 38 7 4 Hidraulic connection diagrams...
Page 39: ...PELLING ECO 39...
Page 40: ...PELLING ECO 40...
Page 43: ...PELLING ECO 43...
Page 56: ...PELLING ECO 56...
Page 57: ...PELLING ECO 57...