![Thermo Scientific Thermo Scientific 3906 Operating Manual Download Page 63](http://html.mh-extra.com/html/thermo-scientific/thermo-scientific-3906/thermo-scientific-3906_operating-manual_1104831063.webp)
Thermo Scientific
Model 3900 Series |
8-17
Handling and Control |
Chapter 8
Timer function: By pressing the channel key (or optionally using the external input)
the timer starts and the corresponding channel switches ON. After the expiry of the
timer-time the channel switches OFF. If the channel receives another signal before
the expiry of time the time, switch reacts as follows:
- After pressing the channel-button = Timer stops and the channel switches OFF.
- Signal on the external input = Timer restarts/ Staircase lighting timer -> Resettable.
Cycle 1 – 4: By pressing the channel key (or optionally using the external input) the
cycle function starts.
Attention: This function is only available if the cycle is activated and defined in advance
within menu Options and submenu Cycle.
Perm on: By pressing the channel key (or optionally using the external input) the
channel switches permanently ON. This status remains active until the channel key of
the device is pressed again.
Perm off: By pressing the channel key (or optionally using the external input) the
channel switches permanently OFF. This status remains active until the channel key
of the device is pressed again.
Additional Adjustments
The Change function, Timer function and Cycle functions will be overridden by the regular
switching program or by a manual over-ride!
Menu
Main menu
Application
Program query
Program
To query the programming steps and remaining memory locations
Program copy
Program
Copy from one channel to another. Memory of the channel won’t be overwritten; the copied switching steps
appear additionally
Permanent by date function is not copied!
Program delete
Program
Deletion of switching time(s). The program for all channels, single channels and single programming steps
within one channel can be deleted.
Date-Time
Adjustment
Adjustment of date and time
Summertime
Adjustment
Adjustment of the daylight saving time mode (ON/OFF)
Language
Adjustment
Choice of languages
Factory Defaults
Adjustment
Reset to the state of delivery.
Date, time and switching program will be lost!
Counter
Options
Displays the hour counter and pulse counter for each channel and the time switch itself.
Summary of Contents for Thermo Scientific 3906
Page 6: ...Table of Contents A 4 Model 3900 Series Thermo Scientific ...
Page 12: ... Safety Notes 1 6 Model 3900 Series Thermo Scientific Chapter 1 ...
Page 22: ... Installation 4 6 Model 3900 Series Thermo Scientific Chapter 4 ...
Page 42: ... Product Description 5 20 Model 3900 Series Thermo Scientific Chapter 5 ...
Page 46: ... Operation 7 2 Model 3900 Series Thermo Scientific Chapter 7 ...
Page 76: ... Disposal 11 2 Model 3900 Series Thermo Scientific Chapter 11 ...
Page 84: ... Specifications 12 8 Model 3900 Series Thermo Scientific Chapter 12 ...
Page 94: ... Service 13 10 Model 3900 Series Thermo Scientific Chapter 13 ...
Page 95: ...Thermo Scientific Model 3900 Series 13 11 Service Chapter 13 ...
Page 99: ...Thermo Scientific Model 3900 Series 13 15 Service Chapter 13 ...
Page 100: ... Service 13 16 Model 3900 Series Thermo Scientific Chapter 13 ...
Page 101: ...Thermo Scientific Model 3900 Series 13 17 Service Chapter 13 ...
Page 102: ... Service 13 18 Model 3900 Series Thermo Scientific Chapter 13 ...