Appendix C
Specifications
*Results may vary under different operating conditions.
Table C–1.
Performance specifications
Accuracy
± 0.15% of span (3–15, 1–17 psi, and 0.2–1.0 bar outputs)
± 0.25% of span (3–27 and 6–30 psi outputs)
Stability
± 0.5% of span/6 months
Repeatability
± 0.05% of span
Dead Band
0.02% of span
Frequency Response
-
3 db at 5 Hz (ISA S26.4.3.1 Config. A)
Temperature Effect
± 0.02% per °F of span (range 0°F to 150°F / -18°C to +66°C) or ±
0.04% per °F of span (range -40°F to 150°F / -40°C to +66°C)
Vibration Effect
<0.25% from 1–200 Hz/1 G
RFI-EMI Effect
< ± 1% effect on zero and span (26–1000 mHz at 30 V/m) when
installed per installation guidelines (
Chapter 2
). Refer to CE
Conformity for test standards.
Table C–2.
Functional specifications
Input
4–20 or 10–50 mA
Output
6–30, 3–27, 3–15, or 1–17 psig and 0.2–1.0 bar
Supply Pressure
Standard Configuration: Minimum of 3 psig and maximum of 10
psig above the maximum calibrated output (except for a 1–17
psig output, which will be 35 psig)
High Pressure Configuration: For 3–15 psi (0.2–1.0 bar) outputs,
standard supply range is 35–100 psi (2.4–6.9 bar). Some units
may be calibrated to operate using a unique range. Contact
Thermo Fisher for other output and supply ranges.
Supply Pressure Effect
Not measurable within the recommended supply pressure range
Operating Current
3.7 mA minimum, 200 mA maximum: continuous at 120°F (50°C);
half-cycle 70 A, 1/120 s at 68°F (20°C)
Loop Load
3.8 Vdc ± 5 ohms (195-ohm load at 20 mA)
Thermo Fisher Scientific
STD5000 & STD6000 User Guide
C-1
Summary of Contents for STD5000
Page 1: ...STD5000 STD6000 Current to Pressure Transducers User Guide P N MA45 5600 00 Revision...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 6: ...This page intentionally left blank...
Page 8: ...This page intentionally left blank...
Page 18: ...This page intentionally left blank...
Page 24: ...This page intentionally left blank...
Page 32: ...This page intentionally left blank...
Page 34: ...This page intentionally left blank...
Page 43: ...Specifications Figure C 2 Thermo Fisher Scientific STD5000 STD6000 User Guide C 7...