Ramsey Oretronic IV Tramp Metal Detector REC 4479C
Page 35
Operator Interface
The TMD IV normally presents the user with the Run screen (Figure 3-2).
Figure 3
–
2. Tramp Metal Detector Run Screen
When the TMD IV is in normal Run mode, the NORMAL LED is lit, the display shows the word COUNT, and the
counter shows the total count of detected tramp. The horizontal bar graph indicates relative signal strength
from tramp metal. The more bars that are displayed, the stronger the signal.
If the TMD IV trips (detects tramp), the ALARM LED lights and the counter shows the coast count, which is the
number of pieces of tramp detected since the system tripped (or while the belt was “coasting” to a stop), if
any. Pressing the RESET (bell) key sets the coast counter to zero and resets the display to the normal mode
(Figure 3-1).
Figure 3
–
3. TMD IV Menu Tree
Run Screen
Calibration*
Coil Balance
C Sensitivity
F Sensitivity
Speed Cal
Clip Cal C
Clip Cal F
Tramp Test
* Opens new menu screen
Conditionally displayed
View
Alarms*
Settings*
Options*
About*
Enter P/W
Options
Synch Input
Bar Rod Detect
Clip Detect
Speed Sensor
External Com
Language
Units
Line Freq
Password Prot
Service*
Defaults
Update S/W
Input Test
Output Test
Restart Log
Setup
Belt Speed
Material Code
Operating Freq
Reverse Dire
Marker Distance
Marker Duration
Clip Length
Bar Length
Modbus Addr
Modbus Port
Modbus Baud
Persistent Bypass