Ramsey Oretronic IV Tramp Metal Detector REC 4479C
Page 25
Figure 2-1B Control Unit Mounting, mild steel enclosure
WARNING.
Make sure the mounting surface is flat so that the fiberglass enclosure does not twist or
warp when mounting bolts are tightened.
Follow this procedure to mount the control unit enclosure.
1.
Open the enclosure door.
2.
Remove the power cover to allow access to the line power terminals.
3.
Bolt the enclosure to a flat, vertical surface using the 2-position mounting feet on the back of the
enclosure (see Figure 2-1A or 2-1B).
4.
Punch the required conduit holes in the bottom of the enclosure for the power supply cable, coil
cables, control wiring, communications cable(s), and any additional signal wires and conduit.
5.
Locate the holes in the appropriate areas of the enclosure to separate high (greater than 30 V) and low
(less than 30 V) voltages (see Figure 2-1A or 2-1B).