Ramsey Oretronic IV Tramp Metal Detector REC 4479C
Page 64
4
12/16
5
10/16
6
8/16
7
6/16
8
4/16
9
2/16
Modbus Address
Base Address:
H1665
Type:
UINT16
Access:
Get/Set
Length:
1
Persistent:
Yes
Min:
1
Units
N/A
Max:
247
This is the address to be used with the modbus serial communication protocol. This parameter only applies for
communications using the comm expansion board. A fixed address of 1 is used for communication using the
built-in USB-to-serial converter.
Modbus Baud Rate
Base Address:
H1681
Type:
UINT16
Access:
Get/Set
Length:
1
Persistent:
Yes
Min:
0
Units
N/A
Max:
5
This parameter specifies the baud rate to be used with the Modbus serial communication protocol. The
encoding is given below. This parameter only applies for communications using the comm expansion board. A
fixed baud rate of 57600 is used for communication using the built-in usb-to-serial converter.
Selection Code
Baud Rate
0
1200
1
2400
2
4800
3
9600
4
19200
5
57600
Modbus Parity
Base Address:
H1697
Type:
UINT16
Access:
Get/Set
Length:
1
Persistent:
Yes
Min:
0
Units
N/A
Max:
2