IST-2255.CN01.01
Istruzione / User’s Manual / Manuel d’utilisation
Pag.1/11
(IST-2255.CN01.01_TS255CN2 (30.04.2014).docx)
Trasmettitore 4÷20mA di CO e NO
2
4÷20mA CO and NO
2
Gas Detector
Sondes à transmetteurs 4÷20mA pour CO et NO
2
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) ITALY
Tel. +39 02 26922890 - Fax +39 02 2133734
http:
www.tecnocontrol.it
e-mail:
TS255CN2
Leggere Attentamente e Conservare questa Istruzione.
Please read and keep this manual
Lire avec soin et garder la notice d’instruction
Con Cartucce Sensori Sostituibili
Inside Replaceable Cartridges Sensor
Avec cartouche capteur échangeable
Modello
/ Model / Modele
Cartuccia Sensore
/
Cartridge Sensor / Cartouche Capteur
TS255CN2
S1
(
CO
) =
ZS EC1
S2
(
NO
2
) =
ZS EN2
Caratteristiche tecniche /
Technical specifications
/
Caractéristiques techniques
Alimentazione /
Power supply / Alimentation
12÷24Vcc (-10/+15%) 2W
12÷24Vdc(-10/+15%) 2W / 12÷24Vcc(-10/+15%) 2W
Gas Rilevato /
Detected Gas / Gaz
CO
NO
2
Sensore /
Sensor Type / Capteur
Elettrochimico /
Electrochemical / électrochimique
Cartuccia Sensore /
Cartridge Sensor / Cartouche capteur
Sostituibile /
Replaceable / échangeable
Uscite /
Outputs / Sortie
4 ÷ 20 mA lineare
/ Linear / linéaire
Resistenza di carico
/ load resistor / résistance de charge
50 ohm / 12Vdc (
-10%
) - 500 ohm / 24Vdc (
-10%
)
Campo di misura /
Standard Range / Champ de mesure
0 ÷ 300 ppm
0÷30 ppm
Tempo di risposta T
90
/
Response Time
T
90
/
Temps de réponse T
90
<60 secondi /
seconds /
secondes
<40 secondi /
seconds /
secondes
Ripetibilità /
Repeatability / Répétitivité
±2% del segnale /
signal
±2 % del segnale /
signal
Precisione /
Accuracy / Precision
10 %
5 %
Deriva a lungo termine /
Long time drift
/
Dérive à long terme
< 5% anno /
year / an
< 12% anno /
year / an
Limite Funzionamento Sensore / Sensor limits
/
Limite échelle
1500 ppm
150 ppm
Vita media in aria pulita /
Average Life in fresh air / Vie moyenne en air pur
4 anni
/ years / ans
4 anni
/ years / ans
Temp./umidità di funzionamento / O
peration Temp./Humidity
Température et hygrométrie de fonctionnement
-20 ÷ + 50 °C / 15÷90 % RH
non condensata /
non condensed / non condensée
Pressione di funzionamento
Operation Pressure
/
Pression
de fonctionnement
Atmosferica ±10%
Atmospheric
±10% /
Atmosphérique
±10%
Tempo massimo di immagazzinamento
Max Storage Time / Temps maximum de stockage
3 mesi / 3 month
/ 3 mois
Temperatura / Umidità di immagazzinamento/
Storage Temp-Humidity / Température et hygrométrie de stockage
0 ÷ + 20°C / 5 ÷ 95 % RH
non condensata /
non condensed / non condensée
Grado di protezione / IP Code
/ Indice de protection
IP65
Resistenza agli urti /
Mechanical strength / Résistance aux chocs
4 Joule
Dimensioni /
Size / Dimensions du boîtier
17,5 x 7 x 166,5 cm
IT
DESCRIZIONE ........................................................................................................................... 2
NOTE SUI GAS RILEVATI ..................................................................................................................... 2
FUNZIONAMENTO ................................................................................................................................. 2
INSTALLAZIONE .................................................................................................................................... 3
AVVERTENZE ........................................................................................................................................ 3
VERIFICHE E CALIBRAZIONE .............................................................................................................. 3
EN
DESCRIPTION ........................................................................................................................... 4
NOTES ON THE DETECTED GAS ........................................................................................................ 4
OPERATIONAL DESCRIPTION ............................................................................................................. 5
INSTALLATION ...................................................................................................................................... 5
WARNING ............................................................................................................................................... 5
TEST and CALIBRATION ...................................................................................................................... 6
FR
DESCRIPTION ........................................................................................................................... 7
CARACTÉRISTIQUES DES GAZ DETECTES ....................................................................................... 7
FONCTIONNEMENT............................................................................................................................... 7
INSTALLATION ...................................................................................................................................... 8
INSTRUCTIONS ..................................................................................................................................... 8
VÉRIFICATIONS ET ETALONNAGE ..................................................................................................... 9