background image

Multilingual Quick Start Guides
Multilingual Essential Safety Instructions
Installation
Operation
Preventive Maintenance
Troubleshooting 

Precision

U

ser M

anua

l

General Purpose Water Baths 

Manual Part Number U01316, August 01, 2016

Summary of Contents for Precision GP 02

Page 1: ...ick Start Guides Multilingual Essential Safety Instructions Installation Operation Preventive Maintenance Troubleshooting Precision Us e r Manual General Purpose Water Baths Manual Part Number U01316...

Page 2: ...allation 3 1 Ventilation 3 1 Cover Installation 3 1 Electrical Requirements 3 2 Approved Fluids 3 3 Filling Requirements 3 6 Filling with Thermal Beads 3 6 Draining 3 7 Optional Accessories 3 8 Steami...

Page 3: ...Chapter 5 Preventive Maintenance 5 1 Cleaning 5 1 Electrical Power Cord 5 1 Chapter 6 Troubleshooting 6 1 Error Displays 6 1 Checklist 6 2 Statement of Conformity Warranty Precision Thermo Scientific...

Page 4: ...ng Slowly fill the reservoir When adding point the opening of a container away from yourself Fill the reservoir with a minimum of one inch of water and a maximum level one inch lower than the tank upp...

Page 5: ...to not save the change The display returns to the home screen Note After a 30 second delay if neither key is pressed the display returns to the home screen any change is not saved Selecting a Preset...

Page 6: ...im Einf llen so dass seine ffnung von Ihnen weg zeigt F r GP B der f llen Sie den Beh lter mindestens bis zu einer F llh he von 2 5 cm mit Wasser und bis maximal 2 5 cm unterhalb des Fl ssigkeitsstand...

Page 7: ...Sie bitte dass nach einer Verz gerung von 30 Sekunden wenn keine der beiden Tasten gedr ckt wird die Anzeige zum Einstiegsbildschirm zur ckkehrt nderungen werden dann nicht gespeichert Auswahl eines...

Page 8: ...ir d au moins 2 5 centim tres 1 pouce d eau et assurez vous que le niveau maximum se trouve 2 5 centim tres 1 pouce en dessous de la surface du r servoir sup rieur D marrage Ne faites pas fonctionner...

Page 9: ...l S lection d une temp rature pr d finie T1 35 0 C T2 41 5 C T3 44 5 C T4 45 5 C Vous pouvez s lectionner une temp rature pr d finie que le bain soit ou non en cours d utilisation l cran d accueil app...

Page 10: ...contenedor lejos de usted En el caso de ba eras GP llene el dep sito con un m nimo de dos cent metros y medio de agua y un nivel m ximo de dos cent metros y medio pro debajo de la superficie superior...

Page 11: ...e inicio En la pantalla de inicio pulse cualquier tecla de flecha para mostrar Pulse y mantenga pulsadas las teclas de flecha para que aparezca el valor del punto de ajuste deseado El rango se encuent...

Page 12: ...himento Encha lentamente o reservat rio Para Banhos GP encha o reservat rio com no m nimo uma polegada de gua e um m ximo n vel de uma polegada por baixo da superf cie superior do tanque Iniciando N o...

Page 13: ...a o ou pressione a tecla program vel abaixo x para n o salvar a altera o A tela retorna tela inicial Nota Depois de um intervalo de 30 segundos se nenhuma tecla for pressionada a tela retornar para a...

Page 14: ...ibility The bath does not have handles Take into account its weight when unpacking and transporting We recommend two people lift heavier baths from the bottom WEEE This product is required to comply w...

Page 15: ...s model and serial number are located on its nameplate label see label sample on the next page Thermo Fisher Scientific 25 Nimble Hill Road Newington NH 03801 Tel 800 258 0830 or 603 436 9444 Fax 603...

Page 16: ...situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicate...

Page 17: ...istivity General Purpose Baths may also use thermal beads Never operate the bath or add fluid to the reservoir with panels removed Operating the baths at high temperature will cause condensation on th...

Page 18: ...h ufiges Abl schen wird n tig sein Es generiert auch Dampf Stellen Sie sicher dass die Fl ssigkeit keine giftigen Gase generieren kann ber der Fl ssigkeit k nnen sich im Gebrauch entz ndbare Gase bil...

Page 19: ...llez de pr s le niveau de liquide Des remplissages fr quents seront n cessaires L eau cr e galement de la vapeur V rifiez qu aucun gaz toxique n est produit par le liquide Les gaz inflammables peuvent...

Page 20: ...precisar n llenados frecuentes Tambi n crea vapor Aseg rese de que el fluido no genera gases t xicos Los gases inflamables pueden acumularse sobre el fluido durante el uso Aseg rese de que el punto d...

Page 21: ...arantia Nunca utilize glicol a 100 Quando utilizar gua acima dos 80 C acompanhe de perto o n vel do fluido pois ser o necess rias reposi es frequentes Tamb m gera vapor Certifique se de que n o s o ge...

Page 22: ...tofniveau goed in de gaten houden en zal u regelmatig vloeistof moeten bijvullen Het cre ert ook stoom Verzeker dat er geen giftige gassen kunnen worden gegenereerd door de vloeistof Er kunnen zich da...

Page 23: ...livello del fluido in quanto potrebbe essere necessario eseguire dei rabbocchi frequenti In tali condizioni si crea anche del vapore Assicurarsi che il fluido non generi gas tossici I gas infiammabil...

Page 24: ...DANGER WARNING CAUTION I II III NEC 100 80 40 C 50 50 O 60 C BG...

Page 25: ...u it jin ch kapalin zp sob zneplatn n z ruky Nikdy nepou vejte 100 glykol P i pou v n vody s teplotou nad 80 C pozorn sledujte hladinu kapaliny nebo bude pot eba ast dopl ov n Doch z tak k vytv en p r...

Page 26: ...r vet Det skaber ogs damp S rg for at ingen giftige gasser kan dannes af v sken Br ndbare gasser kan dannes over v sken under brug S rg for at over temperatursk ringspunktet er indstillet lavere end b...

Page 27: ...DANGER WARNING CAUTION I II III 100 80 C 40 C 50 50 O off 60 C EL...

Page 28: ...e 80 C vett siis j lgige t helepanelikult vedeliku taset vajadusel lisage vedelikku juurde See v ib p hjustada auru teket Veenduge et vedelik ei tekita m rgiseid gaase Kasutamise ajal v ivad vedeliku...

Page 29: ...tet n valvo tarkkaan nesteen tasoa sill sen toistuva lis minen voi olla tarpeen Kyseisess tilassa syntyy my s h yry Varmista ett neste ei aiheuta myrkyllisi kaasuja Palavia kaasuja voi ker nty k yt n...

Page 30: ...a bharrl onadh go minic Cruth far gal leis Cinntigh nach f idir leis an leacht aon gh is thocsaineacha a ghini int Is f idir le g is inadhainte cruinni os cionn an leachta fad a bh onn s in s id Cinn...

Page 31: ...u ine jer e biti potrebna esta dolijevanja Tako er se stvara para Pazite da teku ina ne mo e proizvesti nikakve otrovne plinove Zapaljivi plinovi mogu se nakupiti nad teku inom tijekom upotrebe Pazite...

Page 32: ...akran lehet sz ks g ut nt lt sre Emellett g z is keletkezik Bizonyosodjon meg arr l hogy a folyad kb l nem termel dhet m rgez g z A folyad k felett a haszn lat sor n t zvesz lyes g zok halmoz dhatnak...

Page 33: ...n atid iai steb kite skys io lyg reik s da nai papildyti Jis taip pat garuoja U tikrinkite kad skystis negarins toksini duj Naudojimo metu vir skys io gali susikaupti degios dujos U tikrinkite kad per...

Page 34: ...tvaiks Nodro iniet lai idrums nerad tu toksiskas g zes idruma lieto anas laik virs t var veidoties viegli uzliesmojo as g zes Nodro iniet lai iestat t p rm r gas temperat ras atsl g anas punkta v rt...

Page 35: ...100 glycol Minbarra l ilma qabel ma tu a kwalunkwe fluwidu approvat jew meta tag mel xi manutenzjoni fejn x aktarx li se jkollok kuntatt mal fluwidu irreferi g all SDS jew l EC Safety Data Sheet tal m...

Page 36: ...ziom p ynu poniewa konieczne b dzie cz ste dope nianie Ponadto powoduje tworzenie si pary Upewni si e p yn nie b dzie generowa gaz w toksycznych Podczas pracy nad p ynem mog zgromadzi si gazy palne Up...

Page 37: ...e s monitoriza i cu aten ie nivelul de lichid sunt necesare reumpleri frecvente De asemenea se produc aburi Asigura i v c fluidul nu produce gaze toxice Pe parcusul folosirii lichidului se pot acumula...

Page 38: ...Pri pou it vody s teplotou nad 80 C starostlivo sledujte hladinu kvapaliny bude potrebn ast dolievanie Bude sa tie vytv ra para Uistite sa e kvapalina nem e generova iadne toxick plyny Po as pou vania...

Page 39: ...porabljate vodo segreto na ve kot 80 C pazljivo spremljajte nivo teko ine saj bo potrebno pogosto dolivanje Poleg tega nastaja para Poskrbite da teko ina ne tvori strupenih plinov Med uporabo se lahko...

Page 40: ...ivo pratite nivo te nosti jer e biti potrebna esta dosipanja Tako e se stvara para Pazite da te nost ne mo e proizvesti nikakve otrovne gasove Zapaljivi gasovi mogu da se nakupe nad te no u tokom kori...

Page 41: ...r man troligen kommer i kontakt med v tskan ska man referera till tillverkarens SDS och EU S kerhetsdatablad f r f rsiktighets tg rder vid hantering F rs kra att v tskan inte kan generera giftiga gase...

Page 42: ...e high temperature protection The interior of the bath is constructed of stainless steel and is designed for operation with water The body is made from galvanized steel and is painted for added protec...

Page 43: ...1 8 x 5 9 30 1 x 33 0 x 15 0 11 9 x 13 0 x 5 9 Approximate Weight kg lb 3 5 7 4 9 4 5 10 7 5 16 Electrical Requirements VAC Hz Voltage 10 100 115 50 60 or 200 230 50 60 Compliance CE RoHS UL WEEE Maxi...

Page 44: ...roximate Weight kg lb 10 22 12 26 TBD TBD Electrical Requirements VAC Hz Voltage 10 100 115 50 60 or 200 230 50 60 Compliance CE RoHS UL WEEE Maximum Relative Humidity Non Condensing 80 for temperatur...

Page 45: ...2 4 Precision Thermo Scientific Chapter 2 General Information...

Page 46: ...Installation The bath is designed for continuous operation and for indoor use Never place the bath in a location where excessive heat moisture or corrosive materials are present Ventilation No special...

Page 47: ...otect the bath s internal components Note If the circuit protector activates allow the temperature to cool before resetting Restart the bath Contact us if the circuit protector activates again The bat...

Page 48: ...so recommended to regularly drain and replace fluid especially when higher temperatures are utilized above 40 C Draining and drying the bath after each use is recommended as leaving standing water for...

Page 49: ...e nature of this leaching can cause pitting on metal surfaces Note that the de ionizing process does not remove microorganisms Because of this we recommend de ionized water only with applications that...

Page 50: ...te 25 1 0 Sodium 20 0 3 Sulfate 25 1 Hardness 17 0 05 Total Dissolved Solids 50 10 Other Parameters pH 6 5 8 5 7 8 Resistivity 0 01 0 05 0 1 Unfavorably high total ionized solids TIS can accelerate th...

Page 51: ...urface Note Monitor the fluid level whenever heating the fluid To conserve energy reduce evaporation and increase temperature control accuracy use the supplied gable cover Do not use aluminum foil as...

Page 52: ...gloves Place a suitable receptacle underneath the drain Slowly turn the drain plug until flow is observed When the flow stops close the drain plug Draining GP 10 GP 20 GP 28 and GP 15D only Remove th...

Page 53: ...es Only use the accessories supplied by Thermo Fisher Catalog Number Description 1546230Q 4 Hole Concentric Ring Cover for 10L GP Bath 1546231Q 6 Hole Concentric Ring Cover for 20L and 28L GP Bath Ste...

Page 54: ...art stop the bath Press the two navigation arrows to move through the controller displays and to adjust values Press a soft key to select additional displays Indicates the heater is on The icon flashe...

Page 55: ...ed on the rear of the bath to the I position The screen will momentarily display and then the home screen appears displaying the set point and the audible alarm status The set point is the desired res...

Page 56: ...the change The display returns to the home screen Note After a 30 second delay if neither key is pressed the display returns to the home screen any change is not saved Selecting a Preset Set Point The...

Page 57: ...ck on The bath off time must take into account the start time value For example if you want the bath to start in 60 minutes and then turn it off 30 minutes later set the start time to 1 00 and set the...

Page 58: ...s to return to the home screen Note Low fluid protection is enabled by default When enabled and the reservoir level nears empty the bath will shut down and if enabled the alarm will sound The controll...

Page 59: ...Selecting a Preset procedure Press the soft key below to display the Presets screen To select the desired preset use the arrow keys to highlight it and then press The home screen will appear with the...

Page 60: ...return to the previously displayed screen Changing the Real Time Adjustment CAL RTA requires a calibrated reference thermometer If the displayed temperature does not accurately reflect the actual tem...

Page 61: ...4 8 Precision Thermo Scientific Chapter 4 Operation...

Page 62: ...gh any vent openings mask off all areas except the reservoir After time the circulating bath s stainless steel surfaces may show spots and become tarnished Normal stainless steel cleaners can be used...

Page 63: ...5 2 Precision Thermo Scientific Chapter 5 Preventive Maintenance...

Page 64: ...start the bath if the HTC fault cannot be cleared the bath must be serviced by an authorized Thermo Scientific Temperature Control Service Technician High Temp Fault adjustable high temp fault protect...

Page 65: ...quate temperature control Verify the set point Low end temperature set points require supplemental cooling GP 02 baths require insulation especially in the lid for operation above 90 C Ensure bath ins...

Page 66: ......

Page 67: ...ath that has been operated or maintained in any way contrary to the operating or maintenance instructions specified in this Instruction and Operation Manual This warranty does not cover any bath that...

Page 68: ...are the property of Thermo Fisher Scientific Inc and its subsidiaries Specifications terms and pricing are subject to change Not all products are available in all countries Please consult your local s...

Reviews: