Sarasota 200 Ultrasonic Multipath
Flowmeter
Appendix 1 GAFA PC Software Page A1-19
Thermo Fisher Scientific
APPENDIX 1 GAFA PC SOFTWARE
A1.5.1.1 Log Configuration
Notes
•
Title ID allows a Log name to be entered
•
Log Interval is the period between taking samples of the averaged data. Averaging is
defined in the Station Configuration screen.
•
Select “Halt Log” to stop when the Log memory is full or “Wrap Around” for the most
recent records to over write the oldest when full.
•
As an example, 12 variables at 15 minute logging intervals will fill the memory in 210
days.
•
Select up to 12 Items for Logging
•
“Reset Log” clears the log to allow a new one to be defined.
•
Autogain Stats may be logged for a path for diagnostic purposes. If selected, a path
number will be requested.
•
“Write to Gauge” sends the Log configuration to the Sarasota 200 to start the log.