Sarasota 200 Ultrasonic Multipath
Flowmeter
Appendix 1 GAFA PC Software Page A1-7
Thermo Fisher Scientific
APPENDIX 1 GAFA PC SOFTWARE
A1.4.1.2 (Station configuration) I/O Allocation
Notes - Level Inputs
•
Click on “Allocate” to get pop up screen (right)
•
Up to 4 levels in total may be selected
•
For each one, select a type :
Not Used
if none allocated to that level input
USL
for an ultrasonic upward facing
transducer. For this selection, a multi-drop
address between 1 and 4 must be specified
via the Input drop down. If there is only 1 USL,
use Input 1 on the drop down.
Analogue
for 4-20 mA auxiliary depth inputs.
For this selection, input 1 or 2 must be
selected on the drop down.
Fixed
for a channel where the depth does not
change, e.g a full pipe.
•
Click on “Write” to confirm selected levels to the Sarasota 200.
•
Click on “Exit” to abandon selection.
•
See “Channel Configuration – Level” A1.4.2.3 to set up the selected levels
.