background image

Digital Rocker     14

Section 7 Optional Accessories

13      

 |  

Section 7  Optional Accessories

Description

Cat. No.

Max. Qty.

Figure

Rubber Mat

88882102

88882103

88882101

1

1

5

Rubber Strips
6 Ea/pack

Dimpled Rubber Mat

General Power Adaptor
w/US plug

88870127

88870128

88870129

88870126

1

1

1

1

General Power Adaptor
w/AUS, CN plug

General Power Adaptor
w/EU plug

General Power Adaptor
w/UK plug

Dimensions

298x258x5mm

298x258mm

180x7mm

125VAC 10A 1.8m

250VAC 10A 1.8m

250VAC 16A 1.8m

250VAC13A 1.8m

Section 8 Warranty

THERMO FISHER SCIENTIFIC 
STANDARD PRODUCT WARRANTY

The Warranty Period starts two weeks 
from the date your equipment is shipped 
from our facility. This allows for shipping 
time so the warranty will go into effect at 
approximately the same time your 
equipment is delivered. The warranty 
protection extends to any subsequent 
owner during the first year warranty 
period.

During the first two (2) years, component 
parts proven to be non-conforming in 
materials or workmanship will be 
repaired or replaced at Thermo's 
expense, labor included. Installation and 
calibration are not covered by this 
warranty agreement. The Technical 
Services Department must be contacted 
for warranty determination and direction 
prior to performance of any repairs. 
Expendable items, glass, filters and 
gaskets are excluded from this warranty.

Replacement or repair of components 
parts or equipment under this warranty 
shall not extend the warranty to either 
the equipment or to the component part 
beyond the original warranty period. The 
Technical Services Department must 
give prior approval for return of any 
components or equipment. At Thermo's 
option, all non-conforming parts must 
be returned to Thermo Fisher Scientific 
postage paid and replacement parts are 
shipped FOB destination.

THIS WARRANTY IS EXCLUSIVE AND IN 
LIEU OF ALL OTHER WARRANTIES, 
WHETHER WRITTEN, ORAL OR IMPLIED. 
NO WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE SHALL APPLY. 
Thermo shall not be liable for any 
indirect or consequential damages 
including, without limitation, damages 
relating to lost profits or loss of 
products.

Your local Thermo Sales Office is ready 
to help with comprehensive site 
preparation information before your 
equipment arrives. Printed instruction 
manuals carefully detail equipment 
installation, operation and preventive 
maintenance.

If equipment service is required, please 
call your Technical Services Department 
at 1-866-984-3766, option number 2. 
We're ready to answer your questions on 
equipment warranty, operation, 
maintenance, service and special 
application. Outside the USA, please 
contact local Thermo Technical Services 
Department or local distributor for 
warranty information.

Summary of Contents for 88882001

Page 1: ...fisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca For Research Use Only Not for use in diagnostic procedures 2019 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified Operating Manual Revision A 09 03 2019 ...

Page 2: ... Section 3 Overview Specifications Environmental Conditions Safety Instructions Loads Angle and Speed Section 4 Operation Control Panel Installation Settings Section 5 Safety Tips and Maintenance Section 6 Troubleshooting Section 7 Optional Accessories Section 8 Warranty Information Contents 1 2 3 3 4 4 5 5 5 6 7 8 8 9 9 12 13 14 15 ...

Page 3: ...looding can happen Do not assemble repair modify on your own The product may not work well and electric shock is possible with changes in the efficiency of the product Also this will void the warranty Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coati...

Page 4: ...heck carefully to see if there were damages incurred during transit After unpacking check that all unit parts and accessories are as listed below Contact us or the agent from which you purchased the unit if any components were omitted 3 Section 2 Inspection and Installation Digital Rocker 4 General Power Adaptor US Plug CN Plug EU Plug UK Plug Catalog Number 88882001 1 10 N A N A N A Digital Rocke...

Page 5: ...leaning DO NOT operate the unit if it shows signs of electrical or mechanical damage WARNING DO NOT use the in a hazardous atmosphere or with hazardous materials for which the unit was not designed Also the user should be aware that the protection provided by the equipment may be impaired if accessories used are no provided or recommended by the manufacturer or are used in a manner not specified b...

Page 6: ... Time Tilt display window The window displays cumulative time in continuous mode or remaining time in timer mode The range of time displayed is 0s to 9999 minutes Time indicator The light is on when the instrument is running in Timer Mode Tilt indicator The light is on when the instrument is in Tilt Adjustment Mode Mode button Switch modes between time and Tilt settings Time Tilt setting buttons U...

Page 7: ...strument according to the storage guide Alarm System Err1 If running speed does not match the setting speed the instrument will have a three time reboot and after the three reboots failed there will be a buzzer and then Err1 will be displayed in the Speed display window End of timer The instrument buzzing alarm the End is displayed in the Speed window When the instrument alarms press any key the i...

Page 8: ... immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer Warning Disassembling Assembling without a qualified professional s guidance may cause malfunctioning of the instrument 11 Section 5 Safety Tips and Mainten...

Page 9: ...epairs Expendable items glass filters and gaskets are excluded from this warranty Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the component part beyond the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non ...