4.2 Installation

1. Connect all the components according 
    to the figures shown  on page 4 of this 
    manual. Use grounded power outlet.
2. Press the power switch "I" side and 
    switch on the instrument.

4.3 Settings

Time Settings

1. Continuous mode
Press the “      ” or “      ” arrow button 
below the Time/Tilt display window. 
When the number shown on the Time/ 
Tilt display window starts flashing, press 
“      ” arrow button to decrease the time 
to 00:00 and then release the button. The 
time setting is finished after the number 
shown on the Time/Tilt display window 
flashed twice.

2. Timer mode
Press the “      ” or “      ” arrow button 
below the Time/Tilt display window. 
When the number shown on the  Time/
Tilt display window starts flashing, press 
“      ” or “      ” arrow button to increase or 
decrease the time value. Release the 
button when the time shown on the 
Time/Tilt display window reaches the set 
value. The time setting is finished after 
the number shown on the Time/Tilt 
display window flashed twice.

Speed Settings

Press the “      ” or “      ” arrow button 
below the Speed display window. When

    0100 will show on the Time/Tilt 
    display window. When the time shown 
    in between 0100 to 9999, the default 
    step is 1 minute. 3 seconds after the 
    rocking time is chosen, the Time/Tilt 
    display window will flash and the 
    instrument will automatically take the 
    value shown as the set rocking time. 

Run and Stop

Press “      ” button and the instrument 
will start running with the specified 
settings and the Run indicator light will 
be on. 
The Time/Tilt dispaly window will show 
the cumulative time (Continuous Mode), 
or remaining time (Timer Mode) and the 
Speed display window will show the 
current speed.
 Press “      ” button again and the 
instrument will slow down until it stops. 
The instrument will then be in standby 
and the two display windows will show 
the set values.

Finish Operation

 

After the operation is finished, press the 
power switch at the back right side the 
instrument and put it into the “O” state. 
Unplug the instrument and store the 
instrument according to the storage 
guide.

Alarm System

Err1: If running speed does not match 
the setting speed, the instrument will 
have a three-time reboot, and after the 
three reboots failed, there will be a 
buzzer, and then Err1 will be displayed in 
the Speed display window .

End of timer: The instrument buzzing 
alarm, the "End" is displayed in the Speed 
window.

When the instrument alarms, press any 
key, the instrument is back to the 
standby mode.

Power Recovery

If the power supply is cut off suddenly 
while the instrument is in operation, the 
unit will automatically run at the 
previously set parameter upon power 
restoration. The display windows will 
flash. Press any button to stop flashing.

Mechanical Zero Correction

To ensure accurate and quality rocking, 
the instrument will automatically run 
mechanical zero correction in the 
following situations:
1. First operation after the machine is 
    turned on.
2. First operation after the rocking speed 
    is reset.
3. After 8 hours of continuous operation.

Run

Stop

Run

Stop

the number shown on the Speed display 
window starts flashing, press “      ” or
“      ” arrow button to increase or 
decrease the speed value. Release the 
button when the speed shown on the 
Speed display window reaches the set 
value. The speed setting is finished after 
the number shown on the Speed display 
window has flashed twice. 

Note:

 

press the “      ” or “      ” arrow 

button for a longer time to accelerate the 
setting.

Tilt Angle Setting

1. Press “      ” button and the Tilt 
    indicator light will be on.
2. Press the “      ” or “      ” arrow button 
    below Time/Tilt display window to 
    choose  the tilt needed. The range of 
    tilt displayed on the window is 1 to 
    15°. After 3 seconds, the Time/Tilt 
    display window will flash and the 
    instrument will automatically take the 
    value shown as the set tilt.

Rocking Time Settings

1. Press “      ” button and the Time 
    indicator light will be on.
2. Press the “      ” or “      ” arrow button 
    below Time/Tilt display window. The 
    Time/Tilt display window will show the 
    time value. When the time shown is 
    between 00:01 to 99:59,  the default     
    step of the instrument when changing 
    the time is 1 second. Continue to 
    press “      ” arrow button and the value

Mode

Mode

9      

 |  

Section 4  Operation

Digital Rocker     10

Summary of Contents for 88882001

Page 1: ...fisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca For Research Use Only Not for use in diagnostic procedures 2019 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified Operating Manual Revision A 09 03 2019 ...

Page 2: ... Section 3 Overview Specifications Environmental Conditions Safety Instructions Loads Angle and Speed Section 4 Operation Control Panel Installation Settings Section 5 Safety Tips and Maintenance Section 6 Troubleshooting Section 7 Optional Accessories Section 8 Warranty Information Contents 1 2 3 3 4 4 5 5 5 6 7 8 8 9 9 12 13 14 15 ...

Page 3: ...looding can happen Do not assemble repair modify on your own The product may not work well and electric shock is possible with changes in the efficiency of the product Also this will void the warranty Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coati...

Page 4: ...heck carefully to see if there were damages incurred during transit After unpacking check that all unit parts and accessories are as listed below Contact us or the agent from which you purchased the unit if any components were omitted 3 Section 2 Inspection and Installation Digital Rocker 4 General Power Adaptor US Plug CN Plug EU Plug UK Plug Catalog Number 88882001 1 10 N A N A N A Digital Rocke...

Page 5: ...leaning DO NOT operate the unit if it shows signs of electrical or mechanical damage WARNING DO NOT use the in a hazardous atmosphere or with hazardous materials for which the unit was not designed Also the user should be aware that the protection provided by the equipment may be impaired if accessories used are no provided or recommended by the manufacturer or are used in a manner not specified b...

Page 6: ... Time Tilt display window The window displays cumulative time in continuous mode or remaining time in timer mode The range of time displayed is 0s to 9999 minutes Time indicator The light is on when the instrument is running in Timer Mode Tilt indicator The light is on when the instrument is in Tilt Adjustment Mode Mode button Switch modes between time and Tilt settings Time Tilt setting buttons U...

Page 7: ...strument according to the storage guide Alarm System Err1 If running speed does not match the setting speed the instrument will have a three time reboot and after the three reboots failed there will be a buzzer and then Err1 will be displayed in the Speed display window End of timer The instrument buzzing alarm the End is displayed in the Speed window When the instrument alarms press any key the i...

Page 8: ... immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer Warning Disassembling Assembling without a qualified professional s guidance may cause malfunctioning of the instrument 11 Section 5 Safety Tips and Mainten...

Page 9: ...epairs Expendable items glass filters and gaskets are excluded from this warranty Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the component part beyond the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non ...