30
TK 55032-18-OP-EN
N
No
otte
ess:: The bAt alarm is the unique DSR-III alarm that requires manual
confirmation. The DSR-III will keep in OFF condition until the operator
acknowledges and the voltage is above the BCH value(factory setting
10.5v).
T
Th
he
e w
wa
ay
y tto
o a
acckkn
no
ow
wlle
ed
dg
ge
e tth
hiiss a
alla
arrm
m iiss a
ass ffo
ollllo
ow
wss::
1. Press the Select key once to show the Alarm screen. You will now
see the bAt Alarm code.
2. Press the Select key again to acknowledge the alarm, and Press
the select key again and again until the screen returns to the
standard Display.
Buzzers (Optional)
A buzzer sounds when the vehicle battery and the electrical supply are
connected simultaneously (the unit continues running in standby mode). It
can also sound if the door(s) is open or the return air temperature is out of
range. Buzzers are configurable to different parameters to suit individual
customer needs. Contact your Thermo King Dealer for assistance.