ntt:: Press and release SELECT key twice, the
current Setpoint Temperature in the main compartment and the letters
SP will appear on screen.
2. Press the UP or DOWN arrow keys to select the desired Setpoint
Temperature.
3. Press and release ENTER key to set the setpoint or press and release the
SELECT key to set the setpoint and to change to the R
Re
em
mo
otte
e
C
Co
om
mp
pa
arrttm
me
en
ntt Setpoint Temperature Setting Screen.
IIm
mp
po
orrtta
an
ntt:: If the Select key is not pressed within 20 seconds to select the
new Setpoint Temperature, the unit will continue to run at
the original Setpoint Temperature.
4. R
Re
em
mo
otte
e L
Lo
oa
ad
d C
Co
om
mp
pa
arrttm
me
en
ntt:: The present Setpoint Temperature in the
remote compartment and the letters SP2 will appear on screen.
RCS1709
5. Press the UP or DOWN arrow keys to select the desired Setpoint
Temperature.
6. Press and release the Enter key to set the set point value or press and
release the SELECTION key to set the set point and move to the C
CS
SE
E
((C
Co
om
mp
pa
arrttm
me
en
ntt S
Se
elle
eccttiio
on
n)) screen.
IIm
mp
po
orrtta
an
ntt:: If the Select key or the Enter key is not pressed within 20 seconds
to select the new Setpoint Temperature, the unit will continue to
run at the original Setpoint Temperature.